79 research outputs found

    Detection of group A Streptococcus in tonsils from pediatric patients reveals high rate of asymptomatic streptococcal carriage

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Group A <it>Streptococcus </it>(GAS) causes acute tonsillopharyngitis in children, and approximately 20% of this population are chronic carriers of GAS. Antibacterial therapy has previously been shown to be insufficient at clearing GAS carriage. Bacterial biofilms are a surface-attached bacterial community that is encased in a matrix of extracellular polymeric substances. Biofilms have been shown to provide a protective niche against the immune response and antibiotic treatments, and are often associated with recurrent or chronic bacterial infections. The objective of this study was to test the hypothesis that GAS is present within tonsil tissue at the time of tonsillectomy.</p> <p>Methods</p> <p>Blinded immunofluorescent and histological methods were employed to evaluate palatine tonsils from children undergoing routine tonsillectomy for adenotonsillar hypertrophy or recurrent GAS tonsillopharyngitis.</p> <p>Results</p> <p>Immunofluorescence analysis using anti-GAS antibody was positive in 11/30 (37%) children who had tonsillectomy for adenotonsillar hypertrophy and in 10/30 (33%) children who had tonsillectomy for recurrent GAS pharyngitis. Fluorescent microscopy with anti-GAS and anti-cytokeratin 8 & 18 antibodies revealed GAS was localized to the tonsillar reticulated crypts. Scanning electron microscopy identified 3-dimensional communities of cocci similar in size and morphology to GAS. The characteristics of these communities are similar to GAS biofilms from <it>in vivo </it>animal models.</p> <p>Conclusion</p> <p>Our study revealed the presence of GAS within the tonsillar reticulated crypts of approximately one-third of children who underwent tonsillectomy for either adenotonsillar hypertrophy or recurrent GAS tonsillopharyngitis at the Wake Forest School of Medicine.</p> <p>Trial Registration</p> <p>The tissue collected was normally discarded tissue and no patient identifiers were collected. Thus, no subjects were formally enrolled.</p

    Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    No full text
    CVD diamond shows promising properties for use as a position sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardn ess of diamond we exposed CVD diamond detector samples to 24~GeV/cc and 500~MeV protons up to a fluence of 5×1015 p/cm25\times 10^{15}~p/{\rm cm^2}. We measured the charge collection distance, the ave rage distance electron hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1 times1015 p/cm21\ times 10^{15}~p/{\rm cm^2} and decreases by \approx40~\% at 5×1015 p/cm25\times 10^{15}~p/{\rm cm^2}. Leakage currents of diamond samples were below 1~pA before and after irradiation. The particle indu ced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage curren t. We conclude that CVD diamond detectors are radiation hard to 24~GeV/cc and 500~MeV protons up to at least 1×1015 p/cm21\times 10^{15}~p/{\rm cm^2} without signal loss

    Development of CVD diamond radiation detectors

    Get PDF
    Diamond is a nearly ideal material for detecting ionizing radiation. Its outstanding radiation hardness, fast charge collection and low leakage current allow a diamond detector to be used in high ra diation, high temperature and in aggressive chemical media. We have constructed charged particle detectors using high quality CVD diamond. Characterization of the diamond samples and various detect ors are presented in terms of collection distance, d=μEτd=\mu E \tau, the average distance electron-hole pairs move apart under the influence of an electric field, where μ\mu is the sum of carrier mo bilities, EE is the applied electric field, and τ\tau is the mobility weighted carrier lifetime. Over the last two years the collection distance increased from \sim 75 μ\mum to over 200 μ\mu m. With this high quality CVD diamond a series of micro-strip and pixel particle detectors have been constructed. These devices were tested to determine their position resolution and signal to n oise performance. Diamond detectors were exposed to large fluences of pions, protons and neutrons to establish their radiation hardness properties. The results of these tests and their correlati on with the characterization studies are presented

    Changes to the Fossil Record of Insects through Fifteen Years of Discovery

    Get PDF
    The first and last occurrences of hexapod families in the fossil record are compiled from publications up to end-2009. The major features of these data are compared with those of previous datasets (1993 and 1994). About a third of families (>400) are new to the fossil record since 1994, over half of the earlier, existing families have experienced changes in their known stratigraphic range and only about ten percent have unchanged ranges. Despite these significant additions to knowledge, the broad pattern of described richness through time remains similar, with described richness increasing steadily through geological history and a shift in dominant taxa, from Palaeoptera and Polyneoptera to Paraneoptera and Holometabola, after the Palaeozoic. However, after detrending, described richness is not well correlated with the earlier datasets, indicating significant changes in shorter-term patterns. There is reduced Palaeozoic richness, peaking at a different time, and a less pronounced Permian decline. A pronounced Triassic peak and decline is shown, and the plateau from the mid Early Cretaceous to the end of the period remains, albeit at substantially higher richness compared to earlier datasets. Origination and extinction rates are broadly similar to before, with a broad decline in both through time but episodic peaks, including end-Permian turnover. Origination more consistently exceeds extinction compared to previous datasets and exceptions are mainly in the Palaeozoic. These changes suggest that some inferences about causal mechanisms in insect macroevolution are likely to differ as well

    Tumors of the brachial plexus

    No full text
    corecore