35 research outputs found

    Evaluation of the efficacy of two methods for direct extraction of DNA from Mycobacterium tuberculosis sputum

    Get PDF
    The study was funded by the Helse Nord Tuberculosis Initiative (HNTI).Introduction: Whole genome sequencing (WGS) has shown superiority over other bacterial typing methods and can be used to monitor disease transmission. The long culture period hinders use of WGS as a diagnostic tool for TB. The ideal situation would be to efficiently sequence directly from clinical specimens such as sputum. Attempts to sequence directly from Mtb clinical samples have achieved very low coverage (less than 0.7X). We compared DNA extraction methods for direct extraction from Mycobacterium tuberculosis positive sputum and assessed their suitability for Single Molecule Real Time sequencing. Methodology: We evaluated the extraction efficiency of the PrimeXtract kit and an in-house CTAB method by extracting DNA from Mtb sputum. We evaluated the methods on these parameters: ease of use, efficiency (quantity and purity) and the cost per extraction. Results: The PrimeXtract kit was able to isolate 5.93 mu g/mL ± 0.94, (Mean ± SEM) concentration of DNA and a yield of 0.2975 mu g ± 0.04723, (Mean ± SEM). Comparatively, the CTAB method isolated 1.88 mu g/mL ± 0.38 DNA and a yield of 0.09 mu g ± 0.02. Both concentration and yield from the kit were significantly (p = 0.0002) higher than those from CTAB. The PrimeXtract kit had a DNA purity ratio of 1.69 ± 0.09 compared to the CTAB's 1.73 ± 0.14 and this difference was not statistically different. Conclusion: PrimeXtract kit has a superior extraction efficiency than the CTAB method on Mtb sputum in terms of DNA yield although no significant difference by DNA purity was seen.Publisher PDFPeer reviewe

    Genetic diversity of Mycobacterium tuberculosis clinical isolates in Blantyre, Malawi

    Get PDF
    This work was supported by The Helse Nord Tuberculosis Initiative (HNTI).Despite the high burden of tuberculosis (TB) worldwide, specific factors influencing disease transmission remain elusive. Long term epidemiological studies and in vitro experimental models provide evidence of variable relative fitness of Mycobacterium tuberculosis (Mtb) strains but few such studies are available. Large sequence polymorphisms (LSP) are a robust molecular marker and are feasible as an epidemiological investigative tool. Few Mtb molecular epidemiological studies have been reported in Malawi owing to lack of laboratories with molecular tools. We characterized the genetic diversity of Mtb clinical isolates amongst TB patients in Blantyre, Malawi. We genotyped 64 Mtb clinical isolates using LSP-PCR, assigned specific lineages and confirmed 18 of the isolates using SMRT sequencing. The 64 isolates clustered into 4 lineages (L1-L4) with L4 predominating. There were 10/64 (16%) isolates belonging to L1, 6/64 (9%) belonging to L2, 2/64 (3%) belonging to L3 and 46/64 (72%) belonging to L4. Comparison with a previous study done in Karonga revealed concordance in L1 and L4 but discodance in L2 and L3. The phylogenetic tree constructed, comprised of 3/4 lineages present in Blantyre with 3/18 belonging to L1, 3/18 belonging to L2 and 12/18 belonging to L4. Four Mtb lineages were present in Blantyre with L4 predominating. Larger studies are needed to understand the molecular epidemiology of TB in Blantyre in light of increased bi-directional migration with South Africa.Publisher PDFPeer reviewe

    TST positivity in household contacts of tuberculosis patients : a case-contact study in Malawi

    Get PDF
    This work was supported by a Wellcome Trust Fellowship awarded to DJ Sloan (086757/Z/08/A) a Malawi Liverpool Wellcome Trust (MLW) Core grant awarded by the Wellcome Trust and by a grant from the European Union Action for Diseases of Poverty Program (Sante–2006–105-061).Background:  Screening household contacts of active tuberculosis (TB) patients is recommended for TB control. Due to resource constraints this rarely occurs in lower income countries. Demographic and clinical features of index cases may influence the likelihood of onwards TB transmission. It has also been proposed that accumulation of intracellular lipid bodies within M. tuberculosis cells may also enhance bacterial transmissibility. This study explored whether clinical and bacteriological observations recorded at baseline in TB cases in Malawi could help identify those with the highest risk of onwards transmission, to prioritise contact tracing. Methods:  In this case-contact study, data on clinical presentation, sputum bacterial load and the percentage of lipid body positive acid-fast bacilli (%LB + AFB) on sputum smears were recorded in adults with sputum smear and culture positive pulmonary TB before initiation of therapy. The Tuberculin Skin Test (TST) was used to detect infection with M. tuberculosis amongst household contacts under the age of 15 years. TST positivity of the child contacts was related to characteristics of the index case. Results:  Thirty four index cases brought 56 contacts (median: 1, range: 1–4 contacts each). 37 (66%) of contacts had a positive TST. Cavities or a high percentage of lung affected on index patient CXRs were associated with TST positivity. Multivariate analysis of non-radiological factors showed that male sex, HIV-negative status and raised peripheral blood white blood count (WBC) in index patients were also independent risk factors of TST positivity. Lower %LB + AFB counts were associated with TST positivity on univariate analysis only. Conclusion:  TST positivity is common amongst household contacts of sputum smear positive adult TB patients in Malawi. Contact tracing in this high risk population could be guided by prioritising index cases with CXR cavities and extensive radiological disease or, in the absence of CXRs, those who are HIV-negative with a raised WBC.Publisher PDFPeer reviewe

    Group B Streptococcus and HIV Infection in Pregnant Women, Malawi, 2008–2010

    Get PDF
    To determine whether an association exists between group B streptococcus carriage and HIV infection, we recruited 1,857 pregnant women (21.7% HIV positive) from Queen Elizabeth Central Hospital, Blantyre, Malawi. Overall, group B streptococcus carriage was 21.2% and did not differ by HIV status. However, carriage was increased among HIV-positive women with higher CD4 counts

    A fast extraction-free isothermal LAMP assay for detection of SARS-CoV-2 with potential use in resource-limited settings

    Get PDF
    BACKGROUND: To retain the spread of SARS-CoV-2, fast, sensitive and cost-effective testing is essential, particularly in resource limited settings (RLS). Current standard nucleic acid-based RT-PCR assays, although highly sensitive and specific, require transportation of samples to specialised laboratories, trained staff and expensive reagents. The latter are often not readily available in low- and middle-income countries and this may significantly impact on the successful disease management in these settings. Various studies have suggested a SARS-CoV-2 loop mediated isothermal amplification (LAMP) assay as an alternative method to RT-PCR. METHODS: Four previously published primer pairs were used for detection of SARS-CoV-2 in the LAMP assay. To determine optimal conditions, different temperatures, sample input and incubation times were tested. Ninety-three extracted RNA samples from St. George's Hospital, London, 10 non-extracted nasopharyngeal swab samples from Great Ormond Street Hospital for Children, London, and 92 non-extracted samples from Queen Elisabeth Central Hospital (QECH), Malawi, which have previously been tested for SARS-Cov-2 by quantitative reverse-transcription RealTime PCR (qRT-PCR), were analysed in the LAMP assay. RESULTS: In this study we report the optimisation of an extraction-free colourimetric SARS-CoV-2 LAMP assay and demonstrated that a lower limit of detection (LOD) between 10 and 100 copies/µL of SARS-CoV-2 could be readily detected by a colour change of the reaction within as little as 30 min. We further show that this assay could be quickly established in Malawi, as no expensive equipment is necessary. We tested 92 clinical samples from QECH and showed the sensitivity and specificity of the assay to be 86.7% and 98.4%, respectively. Some viral transport media, used routinely to stabilise RNA in clinical samples during transportation, caused a non-specific colour-change in the LAMP reaction and therefore we suggest collecting samples in phosphate buffered saline (which did not affect the colour) as the assay allows immediate sample analysis on-site. CONCLUSION: SARS-CoV-2 LAMP is a cheap and reliable assay that can be readily employed in RLS to improve disease monitoring and management

    Kinetics of Mycobacterium tuberculosis-specific IFN-γ responses and sputum bacillary clearance in HIV-infected adults during treatment of pulmonary tuberculosis

    Get PDF
    This work was supported by funding from the Wellcome Trust (UK) through Fellowships 092773/Z/10/Z (to D.T.M), 086757/Z/08/Z (to D.J.S) and 088696/Z/09/Z (to H.C.M). Core funding from the Wellcome Trust supports the laboratory and office facilities at the Malawi-Liverpool-Wellcome Trust Clinical Research Programme.In HIV-uninfected adults with pulmonary tuberculosis (TB), anti-TB treatment is associated with changes in Mycobacterium tuberculosis (Mtb)-specific immune responses, which correlate with sputum bacillary load. It is unclear if this occurs in HIV-infected TB patients. We investigated changes in Mtb-specific immune responses and sputum bacillary clearance during anti-TB treatment in HIV-infected and HIV-uninfected adults with pulmonary TB. Sputum bacillary load was assessed by smear microscopy and culture. Mtb-specific IFN-γ secreting peripheral blood mononuclear cells were enumerated using an ELISPOT assay following stimulation with PPD, ESAT-6 and CFP-10. The baseline frequency of Mtb-specific IFN-γ secreting cells was lower in HIV-infected than HIV-uninfected patients (median PPD 32 vs. 104 Spot Forming Units (SFU), p = 0.05; CFP-10 19 vs. 74 SFU, p = 0.01). ESAT-6-specific IFN-γ secreting cells and sputum bacillary load declined progressively during treatment in both HIV-infected and HIV-uninfected patients. HIV infection did not influence the 2-month sputum culture conversion rate (Odds Ratio 0.89, p = 0.95). These findings suggest that changes in ESAT-6-specific immune responses during anti-TB treatment correspond with changes in sputum bacillary load irrespective of host HIV infection status. The utility of Mtb-specific IFN-γ responses as a proxy measure of treatment response in HIV-infected TB patients warrants further evaluation in other settings.Publisher PDFPeer reviewe

    Validation of a direct-to-PCR COVID-19 detection protocol utilizing mechanical homogenization: a model for reducing resources needed for accurate testing

    Get PDF
    Efficient and effective viral detection methodologies are a critical piece in the global response to COVID-19, with PCR-based nasopharyngeal and oropharyngeal swab testing serving as the current gold standard. With over 100 million confirmed cases globally, the supply chains supporting these PCR testing efforts are under a tremendous amount of stress, driving the need for innovative and accurate diagnostic solutions. Herein, the utility of a direct-to-PCR method of SARS-CoV-2 detection grounded in mechanical homogenization is examined for reducing resources needed for testing while maintaining a comparable sensitivity to the current gold standard workflow of nasopharyngeal and oropharyngeal swab testing. In a head-to-head comparison of 30 patient samples, this initial clinical validation study of the proposed homogenization-based workflow demonstrated significant agreeability with the current extraction-based method utilized while cutting the total resources needed in half

    Characterization of DNA methylation in Malawian Mycobacterium tuberculosis clinical isolates.

    Get PDF
    BACKGROUND: Although Mycobacterium tuberculosis (Mtb) strains exhibit genomic homology of >99%, there is considerable variation in the phenotype. The underlying mechanisms of phenotypic heterogeneity in Mtb are not well understood but epigenetic variation is thought to contribute. At present the methylome of Mtb has not been completely characterized. METHODS: We completed methylomes of 18 Mycobacterium tuberculosis (Mtb) clinical isolates from Malawi representing the largest number of Mtb genomes to be completed in a single study using Single Molecule Real Time (SMRT) sequencing to date. RESULTS: We replicate and confirm four methylation disrupting mutations in 4 lineages of Mtb. For the first time we report complete loss of methylation courtesy of C758T (S253L) mutation in the MamB gene of Indo-oceanic lineage of Mtb. Additionally, we report a novel missense mutation G454A (G152S) in the MamA gene of the Euro-American lineage which could potentially be attributed to total disruption of methylation in the CCCAG motif but partial loss in a partner motif. Through a genomic and methylome comparative analysis with a global sample of sixteen, we report previously unknown mutations affecting the pks15/1 locus in L6 isolates. We confirm that methylation in Mtb is lineage specific although some unresolved issues still remain

    The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

    Get PDF
    BACKGROUND: Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. OBJECTIVE: To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. METHODS: Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. RESULTS: Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US9.98);thiswaslowerthanXpert®MTB/RIF(US 9.98); this was lower than Xpert® MTB/RIF (US 13.38) but higher than fluorescence smear microscopy (US$ 0.65). CONCLUSION: The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis
    corecore