435 research outputs found
Invasive disease caused by Haemophilus influenzae in Sweden 1997–2009; evidence of increasing incidence and clinical burden of non‐type b strains
Introduction of a conjugated vaccine against encapsulated Haemophilus influenzae type b (Hib) has led to a dramatic reduction of invasive Hib disease. However, an increasing incidence of invasive disease by H. influenzae non‐type b has recently been reported. Non‐type b strains have been suggested to be opportunists in an invasive context, but information on clinical consequences and related medical conditions is scarce. In this retrospective study, all H. influenzae isolates ( n = 410) from blood and cerebrospinal fluid in three metropolitan Swedish regions between 1997 and 2009 from a population of approximately 3 million individuals were identified. All available isolates were serotyped by PCR ( n = 250). We observed a statistically significant increase in the incidence of invasive H. influenzae disease, ascribed to non‐typeable H. influenzae (NTHi) and encapsulated strains type f (Hif) in mainly individuals >60 years of age. The medical reports from a subset of 136 cases of invasive Haemophilus disease revealed that 48% of invasive NTHi cases and 59% of invasive Hif cases, respectively, met the criteria of severe sepsis or septic shock according to the ACCP/SCCM classification of sepsis grading. One‐fifth of invasive NTHi cases and more than one‐third of invasive Hif cases were admitted to intensive care units. Only 37% of patients with invasive non‐type b disease had evidence of immunocompromise, of which conditions related to impaired humoral immunity was the most common. The clinical burden of invasive non‐type b H. influenzae disease, measured as days of hospitalization/100 000 individuals at risk and year, increased significantly throughout the study period.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87052/1/j.1469-0691.2010.03417.x.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/87052/2/CLM_3417_sm_FigS1.pd
Cerebrospinal Fluid Metals and the Association with Cerebral Small Vessel Disease
BACKGROUND: Brain metal homeostasis is essential for brain health, and deregulation can result in oxidative stress on the brain parenchyma. OBJECTIVE: Our objective in this study was to focus on two hemorrhagic MRI manifestations of small vessel disease [cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS)] and associations with cerebrospinal fluid (CSF) iron levels. In addition, we aimed to analyze CSF biomarkers for dementia and associations with CSF metal levels. METHODS: This is a cross-sectional study of 196 patients who underwent memory clinic investigation, including brain MRI. CSF was collected and analyzed for metals, amyloid-β (Aβ) 42, total tau (T-tau), and phosphorylated tau (P-tau), and CSF/serum albumin ratios. Statistical analyses were performed using generalized linear models. RESULTS: No significant difference was found between CSF metal levels across diagnostic groups. Higher iron and copper levels were associated with higher CSF levels of Aβ42, T-tau, P-tau, and CSF/serum albumin ratios (p < 0.05). Zinc was associated with higher CSF/serum albumin ratios. There was no significant association between CMBs or cSS and CSF iron levels. An increase in CSF iron with the number of CMBs was seen in APOEɛ4 carriers. CONCLUSION: CSF iron levels are elevated with cerebral microbleeds in APOEɛ4 carriers, with no other association seen with hemorrhagic markers of small vessel disease. The association of elevated CSF iron and copper with tau could represent findings of increased neurodegeneration in these patients
Tailoring limb length based on total small bowel length in one anastomosis gastric bypass surgery (TAILOR study):study protocol for a randomized controlled trial
Background: The one anastomosis gastric bypass (OAGB) is being performed by an increasing number of bariatric centers over the world. However, the optimal length of the biliopancreatic (BP) limb remains a topic of discussion. Retrospective studies suggest the benefit of tailoring BP-limb length; however, randomized trials are lacking. The aim of this study is to investigate whether tailoring the length of the BP-limb based on total small bowel length (TSBL) leads to better results in terms of weight loss, vitamin deficiencies, and bowel movements compared to a fixed BP-limb length. Methods: The TAILOR study is a double-blind single-center randomized controlled trial. Patients scheduled for primary OAGB surgery will be randomly allocated either to a standard BP-limb of 150 cm or to a BP-limb length based on their TSBL: TSBL 700 cm, BP-limb 210 cm. The primary outcome is to compare the percent total weight loss (%TWL) at 5 years between the two groups. Secondary outcomes include nutritional deficiencies, remission of comorbidities, symptoms of dumping, quality of life, and daily bowel movements. The study includes a total of 212 patients and is designed to detect a 5% difference in the primary endpoint. Discussion: The TAILOR study will provide new insights into the effect of different BP-limb lengths and the role of the TSBL in the OAGB. The study is designed to provide guidance for bariatric surgeons to determine the optimal BP-limb length in the OAGB
Shift invariant preduals of ℓ<sub>1</sub>(ℤ)
The Banach space ℓ<sub>1</sub>(ℤ) admits many non-isomorphic preduals, for
example, C(K) for any compact countable space K, along with many more
exotic Banach spaces. In this paper, we impose an extra condition: the predual
must make the bilateral shift on ℓ<sub>1</sub>(ℤ) weak<sup>*</sup>-continuous. This is
equivalent to making the natural convolution multiplication on ℓ<sub>1</sub>(ℤ)
separately weak*-continuous and so turning ℓ<sub>1</sub>(ℤ) into a dual Banach
algebra. We call such preduals <i>shift-invariant</i>. It is known that the
only shift-invariant predual arising from the standard duality between C<sub>0</sub>(K)
(for countable locally compact K) and ℓ<sub>1</sub>(ℤ) is c<sub>0</sub>(ℤ). We provide
an explicit construction of an uncountable family of distinct preduals which do
make the bilateral shift weak<sup>*</sup>-continuous. Using Szlenk index arguments, we
show that merely as Banach spaces, these are all isomorphic to c<sub>0</sub>. We then
build some theory to study such preduals, showing that they arise from certain
semigroup compactifications of ℤ. This allows us to produce a large number
of other examples, including non-isometric preduals, and preduals which are not
Banach space isomorphic to c<sub>0</sub>
Laparoscopic Small Bowel Length Measurement in Bariatric Surgery Using a Hand-Over-Hand Technique with Marked Graspers:an Ex Vivo Experiment
Introduction Tailoring limb length in bariatric surgery is a subject of many studies. To acquire the optimal limb length, accurate measurement of the small bowel length is essential. Objective To assess the intra- and inter-individual variability of laparoscopic bowel length measurement using a hand-over-hand technique with marked graspers. Method Four bariatric surgeons and four surgical residents performed measurements on cadaver porcine intestine in a laparoscopic box using marked graspers. Each participant performed 10 times a measurement of three different lengths: 150, 180, and 210 cm. Acceptable percentage deviation from the goal lengths was defined as less than 10%, while unacceptable deviations were defined as more than 15%. Results The bariatric surgeons measured the 150-, 180-, and 210-cm tasks with 4% (CI 0.4, 9), - 6% (CI - 11, - 0.8), and 1% (CI - 4, 6) deviation, respectively. In total, the bariatric surgeons estimated 58 out of 119 times (49%) between the margins of 10% deviation and 36 times (30%) outside the 15% margin. Considerable inter-individual differences were found between the surgeons. The surgical residents underestimated the tasks with 12% (CI - 18, - 6), 16% (CI - 19, - 13), and 18% (CI - 22, - 13), respectively. Conclusion Bariatric surgeons estimated bowel length with on average less than 10% deviation. However, this still resulted in 30% of the measurements with more than 15% deviation. There were considerable inter-individual differences between the surgeons and residents structurally underestimated the bowel length. Ascertainment of measurement accuracy and adequate training is essential for bariatric procedures in which limb length is of importance
Observability and nonlinear filtering
This paper develops a connection between the asymptotic stability of
nonlinear filters and a notion of observability. We consider a general class of
hidden Markov models in continuous time with compact signal state space, and
call such a model observable if no two initial measures of the signal process
give rise to the same law of the observation process. We demonstrate that
observability implies stability of the filter, i.e., the filtered estimates
become insensitive to the initial measure at large times. For the special case
where the signal is a finite-state Markov process and the observations are of
the white noise type, a complete (necessary and sufficient) characterization of
filter stability is obtained in terms of a slightly weaker detectability
condition. In addition to observability, the role of controllability in filter
stability is explored. Finally, the results are partially extended to
non-compact signal state spaces
Quantum Iterated Function Systems
Iterated functions system (IFS) is defined by specifying a set of functions
in a classical phase space, which act randomly on an initial point. In an
analogous way, we define a quantum iterated functions system (QIFS), where
functions act randomly with prescribed probabilities in the Hilbert space. In a
more general setting a QIFS consists of completely positive maps acting in the
space of density operators. We present exemplary classical IFSs, the invariant
measure of which exhibits fractal structure, and study properties of the
corresponding QIFSs and their invariant states.Comment: 12 pages, 1 figure include
Applying an Anti-reflux Suture in the One Anastomosis Gastric Bypass to Prevent Biliary Reflux:a Long-Term Observational Study
INTRODUCTION: The one anastomosis gastric bypass (OAGB) is an effective treatment to induce sustained weight loss in morbidly obese patients. Concerns remain regarding the development of reflux. The aim of this study was to investigate the effect of an "anti-reflux suture" as anti-reflux modification to prevent reflux. METHOD: This is a single-center retrospective cohort study of patients who underwent a primary OAGB at the Center Obesity North-Netherlands (CON) between January 2015 and December 2016. Reflux was defined as symptoms of acid/bilious regurgitation or pyrosis. This was consequently asked and reported at each follow-up visit. Outcomes of patients with an anti-reflux suture were compared to those without. RESULTS: In 414 (59%) of the 703 included patients, an anti-reflux suture was applied. Follow-up at 3 years was 74%. The incidence of reflux did not differ between patients with or without an anti-reflux suture (57 versus 56%, respectively; P = 0.9). The presence of an anti-reflux suture was significantly associated with a lower incidence of conversion to Roux-en-Y gastric bypass (RYGB) for reflux (OR 0.56, 95%CI 0.34-0.91). Patients preoperatively diagnosed with gastroesophageal reflux disease (GERD) were 5.2 times more likely to need a conversion to RYGB for reflux (95%CI 2.7-10.1). CONCLUSION: The presence of preoperative GERD should be weighted heavily in the decision to perform an OAGB as this is a major risk factor for conversion surgery due to reflux. The anti-reflux suture might be a valuable addition to the procedure of the OAGB because it results in fewer conversion surgeries for reflux
Coherent States Measurement Entropy
Coherent states (CS) quantum entropy can be split into two components. The
dynamical entropy is linked with the dynamical properties of a quantum system.
The measurement entropy, which tends to zero in the semiclassical limit,
describes the unpredictability induced by the process of a quantum approximate
measurement. We study the CS--measurement entropy for spin coherent states
defined on the sphere discussing different methods dealing with the time limit
. In particular we propose an effective technique of computing
the entropy by iterated function systems. The dependence of CS--measurement
entropy on the character of the partition of the phase space is analysed.Comment: revtex, 22 pages, 14 figures available upon request (e-mail:
[email protected]). Submitted to J.Phys.
- …