1,422 research outputs found

    Electrically Tunable Excitonic Light Emitting Diodes based on Monolayer WSe2 p-n Junctions

    Full text link
    Light-emitting diodes are of importance for lighting, displays, optical interconnects, logic and sensors. Hence the development of new systems that allow improvements in their efficiency, spectral properties, compactness and integrability could have significant ramifications. Monolayer transition metal dichalcogenides have recently emerged as interesting candidates for optoelectronic applications due to their unique optical properties. Electroluminescence has already been observed from monolayer MoS2 devices. However, the electroluminescence efficiency was low and the linewidth broad due both to the poor optical quality of MoS2 and to ineffective contacts. Here, we report electroluminescence from lateral p-n junctions in monolayer WSe2 induced electrostatically using a thin boron nitride support as a dielectric layer with multiple metal gates beneath. This structure allows effective injection of electrons and holes, and combined with the high optical quality of WSe2 it yields bright electroluminescence with 1000 times smaller injection current and 10 times smaller linewidth than in MoS2. Furthermore, by increasing the injection bias we can tune the electroluminescence between regimes of impurity-bound, charged, and neutral excitons. This system has the required ingredients for new kinds of optoelectronic devices such as spin- and valley-polarized light-emitting diodes, on-chip lasers, and two-dimensional electro-optic modulators.Comment: 13 pages main text with 4 figures + 4 pages upplemental material

    Ray blight of pyrethrum in Australia: a review of the current status and future opportunities

    Get PDF
    Ray blight caused by Stagonosporopsis tanaceti is one of the most important diseases of pyrethrum (Tanacetum cinerariifolium), a perennial herbaceous plant cultivated for the extraction of insecticidal pyrethrins in Australia. The disease is responsible for complete yield loss in severe outbreaks. Infected seed is considered as the principal source of S. tanaceti. Infection hyphae remain only in the seed coat and not in the embryo, resulting in pre- and post-emergence death of seedlings and latent infection. Therefore, quantification of the level of infection by S. tanaceti within seed using a qPCR assay is important for efficient management of the disease. Stagonosporopsis tanaceti completes its life cycle within 12 days after leaf infection through production of pycnidia and can infect every tissue of the pyrethrum plant except the vascular and root tissues. Ray blight epidemics occur in pyrethrum fields through splash dispersal of pycnidiospores between adjacent plants. Besides steam sterilization, thiabendazole/thiram and fludioxonil are effective seed-treating chemicals in controlling S. tanaceti before planting begins. Ray blight is currently managed in the field through the foliar application of strobilurin fungicides in the first 1–2 years of crop establishment. Later on, difenoconazole and multisite specific fungicides in the next 2–3 years during early spring successfully reduce ray blight infestation. Avoiding development of resistance to fungicides will require more sustainable management of ray blight including the development and deployment of resistant cultivars

    Dual-gated bilayer graphene hot electron bolometer

    Full text link
    Detection of infrared light is central to diverse applications in security, medicine, astronomy, materials science, and biology. Often different materials and detection mechanisms are employed to optimize performance in different spectral ranges. Graphene is a unique material with strong, nearly frequency-independent light-matter interaction from far infrared to ultraviolet, with potential for broadband photonics applications. Moreover, graphene's small electron-phonon coupling suggests that hot-electron effects may be exploited at relatively high temperatures for fast and highly sensitive detectors in which light energy heats only the small-specific-heat electronic system. Here we demonstrate such a hot-electron bolometer using bilayer graphene that is dual-gated to create a tunable bandgap and electron-temperature-dependent conductivity. The measured large electron-phonon heat resistance is in good agreement with theoretical estimates in magnitude and temperature dependence, and enables our graphene bolometer operating at a temperature of 5 K to have a low noise equivalent power (33 fW/Hz1/2). We employ a pump-probe technique to directly measure the intrinsic speed of our device, >1 GHz at 10 K.Comment: 5 figure

    Evidence at a glance: error matrix approach for overviewing available evidence

    Get PDF
    Contains fulltext : 88651.pdf (publisher's version ) (Open Access)BACKGROUND: Clinical evidence continues to expand and is increasingly difficult to overview. We aimed at conceptualizing a visual assessment tool, i.e., a matrix for overviewing studies and their data in order to assess the clinical evidence at a glance. METHODS: A four-step matrix was constructed using the three dimensions of systematic error, random error, and design error. Matrix step I ranks the identified studies according to the dimensions of systematic errors and random errors. Matrix step II orders the studies according to the design errors. Matrix step III assesses the three dimensions of errors in studies. Matrix step IV assesses the size and direction of the intervention effect. RESULTS: The application of this four-step matrix is illustrated with two examples: peri-operative beta-blockade initialized in relation to surgery versus placebo for major non-cardiac surgery, and antiarrhythmics for maintaining sinus rhythm after cardioversion of atrial fibrillation. When clinical evidence is deemed both internally and externally valid, the size of the intervention effect is to be assessed. CONCLUSION: The error matrix provides an overview of the validity of the available evidence at a glance, and may assist in deciding which interventions to use in clinical practice

    Graphene plasmonics

    Full text link
    Two rich and vibrant fields of investigation, graphene physics and plasmonics, strongly overlap. Not only does graphene possess intrinsic plasmons that are tunable and adjustable, but a combination of graphene with noble-metal nanostructures promises a variety of exciting applications for conventional plasmonics. The versatility of graphene means that graphene-based plasmonics may enable the manufacture of novel optical devices working in different frequency ranges, from terahertz to the visible, with extremely high speed, low driving voltage, low power consumption and compact sizes. Here we review the field emerging at the intersection of graphene physics and plasmonics.Comment: Review article; 12 pages, 6 figures, 99 references (final version available only at publisher's web site

    Epidemiology and reporting characteristics of preclinical systematic reviews

    Get PDF
    In an effort to better utilize published evidence obtained from animal experiments, systematic reviews of preclinical studies are increasingly more common-along with the methods and tools to appraise them (e.g., SYstematic Review Center for Laboratory animal Experimentation [SYRCLE's] risk of bias tool). We performed a cross-sectional study of a sample of recent preclinical systematic reviews (2015-2018) and examined a range of epidemiological characteristics and used a 46-item checklist to assess reporting details. We identified 442 reviews published across 43 countries in 23 different disease domains that used 26 animal species. Reporting of key details to ensure transparency and reproducibility was inconsistent across reviews and within article sections. Items were most completely reported in the title, introduction, and results sections of the reviews, while least reported in the methods and discussion sections. Less than half of reviews reported that a risk of bias assessment for internal and external validity was undertaken, and none reported methods for evaluating construct validity. Our results demonstrate that a considerable number of preclinical systematic reviews investigating diverse topics have been conducted; however, their quality of reporting is inconsistent. Our study provides the justification and evidence to inform the development of guidelines for conducting and reporting preclinical systematic reviews

    Assessment of Survivor Concerns (ASC): A newly proposed brief questionnaire

    Get PDF
    BACKGROUND: The purpose of this study was to design a brief questionnaire to measure fears about recurrence and health in cancer survivors. Research involving fear of recurrence has been increasing, indicating that it is an important concern among cancer survivors. METHODS: We developed and tested a six-item instrument, the Assessment of Survivor Concerns (ASC). Construct validity was examined in a multiple group confirmatory factor analysis (CFA) with 592 short-term and 161 long-term cancer survivors. Convergent and discriminant validity was examined through comparisons with the PANAS (Positive and Negative Affect Schedule) and the CES-D (Center for Epidemiologic Studies Depression) measures. RESULTS: CFA models for the ASC with short- and long-term survivors showed good fit, with equivalent structure across both groups of cancer survivors. Convergent and discriminant validity was also supported through analyses of the PANAS and CES-D. One item (children's health worry) did not perform as well as the others, so the models were re-run with the item excluded, and the overall fit was improved. CONCLUSION: The ASC showed excellent internal consistency and validity. We recommend the revised five-item instrument as an appropriate measure for assessment of cancer survivor worries

    Graphene Photonics and Optoelectronics

    Full text link
    The richness of optical and electronic properties of graphene attracts enormous interest. Graphene has high mobility and optical transparency, in addition to flexibility, robustness and environmental stability. So far, the main focus has been on fundamental physics and electronic devices. However, we believe its true potential to be in photonics and optoelectronics, where the combination of its unique optical and electronic properties can be fully exploited, even in the absence of a bandgap, and the linear dispersion of the Dirac electrons enables ultra-wide-band tunability. The rise of graphene in photonics and optoelectronics is shown by several recent results, ranging from solar cells and light emitting devices, to touch screens, photodetectors and ultrafast lasers. Here we review the state of the art in this emerging field.Comment: Review Nature Photonics, in pres

    Crystal Structure of PrgI-SipD: Insight into a Secretion Competent State of the Type Three Secretion System Needle Tip and its Interaction with Host Ligands

    Get PDF
    Many infectious Gram-negative bacteria, including Salmonella typhimurium, require a Type Three Secretion System (T3SS) to translocate virulence factors into host cells. The T3SS consists of a membrane protein complex and an extracellular needle together that form a continuous channel. Regulated secretion of virulence factors requires the presence of SipD at the T3SS needle tip in S. typhimurium. Here we report three-dimensional structures of individual SipD, SipD in fusion with the needle subunit PrgI, and of SipD:PrgI in complex with the bile salt, deoxycholate. Assembly of the complex involves major conformational changes in both SipD and PrgI. This rearrangement is mediated via a π bulge in the central SipD helix and is stabilized by conserved amino acids that may allow for specificity in the assembly and composition of the tip proteins. Five copies each of the needle subunit PrgI and SipD form the T3SS needle tip complex. Using surface plasmon resonance spectroscopy and crystal structure analysis we found that the T3SS needle tip complex binds deoxycholate with micromolar affinity via a cleft formed at the SipD:PrgI interface. In the structure-based three-dimensional model of the T3SS needle tip, the bound deoxycholate faces the host membrane. Recently, binding of SipD with bile salts present in the gut was shown to impede bacterial infection. Binding of bile salts to the SipD:PrgI interface in this particular arrangement may thus inhibit the T3SS function. The structures presented in this study provide insight into the open state of the T3SS needle tip. Our findings present the atomic details of the T3SS arrangement occurring at the pathogen-host interface

    Expression of Snail2 in long bone osteosarcomas correlates with tumour malignancy

    Get PDF
    Snail2 is a marker of malignancy in epithelial tumours; however, in sarcomas, it is not known if this protein is present. Here we examine the expression of Snail2 in one type of sarcoma, osteosarcoma, and explore its relationship to tumour grade, subtype and anatomical location in cases of long bone and cranial bone osteosarcoma. Long bone osteosarcomas typically have a much greater metastatic capability and a poorer prognosis. We find that Snail2 is expressed in the three main subtypes of long bone osteosarcoma—osteoblastic, chondroblastic and fibroblastic. Regression analysis showed that Snail 2 expression was statistically correlated with tumour grade (p = 0.014) in all of these subtypes. Snail2 was only expressed in high-grade cranial bone osteosarcomas, suggesting a link between Snail2 expression and metastasis. This is the first time Snail2 has been associated with any sarcoma, and this study shows that Snail2 may be a useful prognostic marker for this disease
    corecore