679 research outputs found
Pickoff and spin-conversion quenchings of ortho-positronium in oxygen
The quenching processes of the thermalized ortho-positronium(o-Ps) on an
oxygen molecule have been studied by the positron annihilation age-momentum
correlation techinique(AMOC). The Doppler broadening spectrum of the 511 keV
gamma-rays from the 2gamma annihilation of o-Ps in O_2 has been measured as a
function of the o-Ps age. The rate of the quenching, consisting of the pickoff
and the spin-conversion, is estimated from the positron lifetime spectrum. The
ratio of the pickoff quenching rate to the spin-conversion rate is deduced from
the Doppler broadening of the 511 keV gamma-rays from the annihilation of the
o-Ps. The pickoff parameter ^1Z_eff, the effective number of the electrons per
molecule which contribute to the pickoff quenching, for O_2 is determined to be
0.6 +- 0.4. The cross-section for the elastic spin-conversion quenching is
determined to be (1.16 +- 0.01) * 10^{-19} cm^2.Comment: 4 pages with 5 eps figures, LaTeX2e(revtex4
Abnormal positioning of the common carotid artery clinically diagnosed as a submandibular mass
The common carotid artery (CCA) usually runs along the long axis of the neck, although it is occasionally found in an abnormal position or is displaced. We report a case of an 86-year-old woman in whom the CCA was identified in the submandibular area. The patient visited our clinic and reported soft tissue swelling in the right submandibular area. It resembled a tumor mass or a swollen lymph node. Computed tomography showed that it was the right CCA that had been bent forward and was running along the submandibular subcutaneous area. Ultrasonography verified the diagnosis. No other lesions were found on the diagnostic images. Consequently, the patient was diagnosed as having abnormal CCA positioning. Although this condition generally requires no treatment, it is important to follow-up the abnormality with diagnostic imaging because of the risk of cerebrovascular disorders
T2 relaxation times of the retrodiscal tissue in patients with temporomandibular joint disorders and in healthy volunteers: A comparative study
Objective. The aims of this study were to compare the temporomandibular joint (TMJ) retrodiscal tissue T2 relaxation times between patients with temporomandibular disorders (TMDs) and asymptomatic volunteers and to assess the diagnostic potential of this approach. Study Design. Patients with TMD (n = 173) and asymptomatic volunteers (n = 17) were examined by using a 1.5-T magnetic resonance scanner. The imaging protocol consisted of oblique sagittal, T2-weighted, 8-echo fast spin echo sequences in the closed mouth position. Retrodiscal tissue T2 relaxation times were obtained. Additionally, disc location and reduction, disc configuration, joint effusion, osteoarthritis, and bone edema or osteonecrosis were classified using MRI scans. The T2 relaxation times of each group were statistically compared. Results. Retrodiscal tissue T2 relaxation times were significantly longer in patient groups than in asymptomatic volunteers (P < .01). T2 relaxation times were significantly longer in all of the morphologic categories. The most important variables affecting retrodiscal tissue T2 relaxation times were disc configuration, joint effusion, and osteoarthritis. Conclusion. Retrodiscal tissue T2 relaxation times of patients with TMD were significantly longer than those of healthy volunteers. This finding may lead to the development of a diagnostic marker to aid in the early detection of TMDs
Nonpolar optical scattering of positronium in magnesium fluoride
We report the results of the analysis of the temperature broadening of the
momentum distribution of delocalized Positronium (Ps) in Magnesium Fluoride in
terms of optical deformation-potential scattering model (long-wavelength
optical phonons). The Ps optical deformation-potential coupling constant
in MgF has been determined to be eV/cm.
We also show that the Ps momentum distribution is sensitive to second-order
phase transitions in those crystals where optical deformation-potential
scattering is allowed in one and forbidden in another crystalline phase
Very High Energy Gamma Rays from PSR1706-44
We have obtained evidence of gamma-ray emission above 1 TeV from PSR1706-44,
using a ground-based telescope of the atmospheric \v{C}erenkov imaging type
located near Woomera, South Australia. This object, a -ray source
discovered by the COS B satellite (2CG342-02), was identified with the radio
pulsar through the discovery of a 102 ms pulsed signal with the EGRET
instrument of the Compton Gamma Ray Observatory. The flux of the present
observation above a threshold of 1 TeV is 1 10
photons cm s, which is two orders of magnitude smaller than the
extrapolation from GeV energies. The analysis is not restricted to a search for
emission modulated with the 102 ms period, and the reported flux is for all
-rays from PSR1706-44, pulsed and unpulsed. The energy output in the
TeV region corresponds to about 10 of the spin down energy loss rate of
the neutron star.Comment: 13 pages, latex format (article), 2 figures include
Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments
Most of the Ultra High Energy Cosmic Ray (UHECR) experiments and projects
(HiRes, AUGER, TA, EUSO, TUS,...) use air fluorescence to detect and measure
extensive air showers (EAS). The precise knowledge of the Fluorescence Light
Yield (FLY) is of paramount importance for the reconstruction of UHECR. The
MACFLY - Measurement of Air Cherenkov and Fluorescence Light Yield - experiment
has been designed to perform such FLY measurements. In this paper we will
present the results of FLY in the 290-440 nm wavelength range for dry air and
pure nitrogen, both excited by electrons with energy of 1.5 MeV, 20 GeV and 50
GeV. The experiment uses a 90Sr radioactive source for low energy measurement
and a CERN SPS electron beam for high energy. We find that the FLY is
proportional to the deposited energy (E_d) in the gas and we show that the air
fluorescence properties remain constant independently of the electron energy.
At the reference point: atmospheric dry air at 1013 hPa and 23C, the ratio
FLY/E_d=17.6 photon/MeV with a systematic error of 13.2%.Comment: 19 pages, 8 figures. Accepted for publication in Astroparticle
Physic
Comparison of the diagnostic value of symmetric dimethylarginine, cystatin C, and creatinine for detection of decreased glomerular filtration rate in dogs
BACKGROUND: Early detection of decreased glomerular filtration rate (GFR) in dogs is challenging. Current methods are insensitive and new biomarkers are required. OBJECTIVE: To compare overall diagnostic performance of serum symmetric dimethylarginine (SDMA) and serum cystatin C to serum creatinine, for detection of decreased GFR in clinically stable dogs, with or without chronic kidney disease (CKD). ANIMALS: Ninety-seven client-owned dogs: 67 dogs with a diagnosis or suspicion of CKD and 30 healthy dogs were prospectively included. METHODS: Prospective diagnostic accuracy study. All dogs underwent physical examination, systemic arterial blood pressure measurement, urinalysis, hematology and blood biochemistry analysis, cardiac and urinary ultrasound examinations, and scintigraphy for estimation of glomerular filtration rate (mGFR). Frozen serum was used for batch analysis of SDMA and cystatin C. RESULTS: The area under the curve of creatinine, SDMA, and cystatin C for detection of an mGFR <30.8 mL/min/L was 0.98 (95% confidence interval [CI], 0.93-1.0), 0.96 (95% CI, 0.91-0.99), and 0.87 (95% CI, 0.79-0.93), respectively. The sensitivity of both creatinine and SDMA at their prespecified cutoffs (115 μmol/L [1.3 mg/dL] and 14 μg/dL) for detection of an abnormal mGFR was 90%. The specificity was 90% for creatinine and 87% for SDMA. When adjusting the cutoff for cystatin C to correspond to a diagnostic sensitivity of 90% (0.49 mg/L), specificity was lower (72%) than that of creatinine and SDMA. CONCLUSIONS AND CLINICAL IMPORTANCE: Overall diagnostic performance of creatinine and SDMA for detection of decreased mGFR was similar. Overall diagnostic performance of cystatin C was inferior to both creatinine and SDMA
Change of temporomandibular joint disk configuration and clinical findings following conservative treatment
The objective of this study was to evaluate the relationship between changes in the disk status (position and reduction) and changes in the clinical findings following conservative temporomandibular joint(TMJ) treatment. The subjects consisted of 164 patients (328 joints) having TMJ disorders. Clinical examination and MR imaging were performed on all patients before and after conservative treatment. Clinical assessments included joint noise, pain and inter-incisal distance(IID). Disk position and reduction was classified as "improved", "worsened", or "unchanged" following treatment. In the 55 joints where disk position was improved, noise was improved in 37(67.2%) and worsened in 6(10.9%). In the 48 joints where disk reduction was improved, noise was improved in 34(70.8%) and worsened in 4(8.3%). There was a significant relationship between improvement in the disk status and improvement in the noise. In 55 joins where the disk position was improved, pain symptoms were disappeared in 22(40.0%) and newly occured in 4(7.3%). In the 56 joins where the pain was disappeared, disk reduction improved in 22(39.3%), but became worse in 22(39.3%) joints. In 56 joints where the pain was disappeared, disk reduction improved in 17(30.4%) joints disk reduction improved in 17(30.4%) joins but became worse in 32(57%). There was no significant relationship between improvement in the disk status and improvement in the pain. Treatment has no significant influence on IID. We conclude that there was no relationship between improvement in the disk status and improvement in the joint pain and IID after conservative treatment, but there was close relationship between disk stutus and the joint noise in their changes
Treatment outcomes of real-time intraoral sonography-guided implantation technique of 198Au grain brachytherapy for T1 and T2 tongue cancer
It is often challenging to determine the accurate size and shape of oral lesions through computed tomography (CT) or magnetic resonance imaging (MRI) when they are very small or obscured by metallic artifacts, such as dental prostheses. Intraoral ultrasonography (IUS) has been shown to be beneficial in obtaining precise information about total tumor extension, as well as the exact location and guiding the insertion of catheters during interstitial brachytherapy. We evaluated the role of IUS in assessing the clinical outcomes of interstitial brachytherapy with 198Au grains in tongue cancer through a retrospective medical chart review. The data from 45 patients with T1 (n = 21) and T2 (n = 24) tongue cancer, who were mainly treated with 198Au grain implants between January 2005 and April 2019, were included in this study. 198Au grain implantations were carried out, and positioning of the implants was confirmed by IUS, to ensure that 198Au grains were appropriately placed for the deep border of the tongue lesion. The five-year local control rates of T1 and T2 tongue cancers were 95.2% and 95.5%, respectively. We propose that the use of IUS to identify the extent of lesions and the position of implanted grains is effective when performing brachytherapy with 198Au grains
Prognostic factors for lymph node metastasis from upper gingival carcinomas
This study sought to identify tumor characteristics that associate with regional lymph node metastases in squamous cell carcinomas originating in the upper gingiva
- …