179 research outputs found

    A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope.

    Get PDF
    BACKGROUND: MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. OBJECTIVE: To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). DESIGN: Prospective, multicenter, comparative study. SETTING: Six academic hospitals. PATIENTS: A total of 105 patients with OGIB. INTERVENTION: Patients ingested both the MC and PC capsules sequentially in a randomized fashion. MAIN OUTCOME MEASUREMENTS: Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. RESULTS: Data analysis resulted in 43 (48%) abnormal cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P \u3c .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). LIMITATIONS: Readers were not blinded to the particular capsule they were reading. CONCLUSION: A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. (Clinical trial registration number: NCT00878982.)

    On Distant Speech Recognition for Home Automation

    No full text
    The official version of this draft is available at Springer via http://dx.doi.org/10.1007/978-3-319-16226-3_7International audienceIn the framework of Ambient Assisted Living, home automation may be a solution for helping elderly people living alone at home. This study is part of the Sweet-Home project which aims at developing a new home automation system based on voice command to improve support and well-being of people in loss of autonomy. The goal of the study is vocal order recognition with a focus on two aspects: distance speech recognition and sentence spotting. Several ASR techniques were evaluated on a realistic corpus acquired in a 4-room flat equipped with microphones set in the ceiling. This distant speech French corpus was recorded with 21 speakers who acted scenarios of activities of daily living. Techniques acting at the decoding stage, such as our novel approach called Driven Decoding Algorithm (DDA), gave better speech recognition results than the baseline and other approaches. This solution which uses the two best SNR channels and a priori knowledge (voice commands and distress sentences) has demonstrated an increase in recognition rate without introducing false alarms

    Precision of the PET activity range during irradiation with <sup>10</sup>C, <sup>11</sup>C, and <sup>12</sup>C beams

    Get PDF
    Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable 12C ions, the positron emitters 10,11C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes 11C and 10C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 107 ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for 10C, 11C and 12C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from 11C to 10C than when going from 12C to 11C. The much better precision for 10C is due to its much shorter half-life, which, contrary to the case of 11C, also enables to include the in-spill data in the image formation. Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.</p

    A concept for trial institutions focussing on randomised controlled trials in surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although considered the reference standard for generating valid scientific evidence of a treatment's benefits and harms, the number of Randomised Controlled Trials (RCT) comparing surgical techniques remains low. Much effort has been made in order to overcome methodological issues and improve quality of RCTs in surgery. To the present there has been, however, only little emphasis on development and maintenance of institutions for implementation of adequately designed and conducted surgical RCTs.</p> <p>Mehods/Design</p> <p>Description of the developments in surgical RCT infrastructure in Germany between 2001 and 2006. Cross sectional evaluation of completed and ongoing surgical RCTs within the German Surgical Society and the Clinical Study Centre, Department of Surgery, University of Heidelberg.</p> <p>Results</p> <p>Foundation of a national Clinical Trial Centre (CTC) for the organisation of multi-centre RCTs in the surgical setting (Study Center of the German Surgical Society, SDGC). Establishment of a network of CTCs with affiliated Clinical Sites (CSs) to enhance patient recruitment and shorten the duration of RCTs. Since its foundation four surgical RCTs with a total sample size of 1650 patients (1006 of these randomised) have been supervised by the SDGC with 35 CSs involved in patient recruitment. Five further CTCs were set up in 2006. Together with their affiliated CSs a network has been organised providing improved conditions for the conduction of surgical RCTs.</p> <p>Conclusion</p> <p>Improvement of infrastructure substantially facilitates integration of RCTs into routine surgical practice. A network of collaborating CTCs and CSs can provide an adequate infrastructure for the conduction of multi-centre RCTs.</p

    Pilot study of an interactive voice response system to improve medication refill compliance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sub-optimal adherence to prescribed medications is well documented. Barriers to medication adherence include medication side effects, cost, and forgetting to take or refill medications. Interactive Voice Response (IVR) systems show promise as a tool for reminding individuals to take or refill medications. This pilot study evaluated the feasibility and acceptability of using an IVR system for prescription refill and daily medication reminders. We tested two novel features: personalized, medication-specific reminder messages and communication via voice recognition.</p> <p>Methods</p> <p>Patients enrolled in a study of electronic prescribing and medication management in Quebec, Canada who were taking chronic disease-related drugs were eligible to participate. Consenting patients had their demographic, telephone, and medication information transferred to an IVR system, which telephoned patients to remind them to take mediations and/or refill their prescriptions. Facilitators and barriers of the IVR system use and acceptability of the IVR system were assessed through a structured survey and open-ended questions administered by telephone interview.</p> <p>Results</p> <p>Of the 528 eligible patients who were contacted, 237 refused and 291 consented; 99 participants had started the pilot study when it was terminated because of physician and participant complaints. Thirty-eight participants completed the follow-up interview. The majority found the IVR system's voice acceptable, and did not have problems setting up the time and location of reminder calls. However, many participants experienced technical problems when called for reminders, such as incorrect time of calls and voice recognition difficulties. In addition, most participants had already refilled their prescriptions when they received the reminder calls, reporting that they did not have difficulties remembering to refill prescriptions on their own. Also, participants were not receptive to speaking to an automated voice system.</p> <p>Conclusion</p> <p>IVR systems designed to improve medication compliance must address key technical and performance issues and target those individuals with reported memory difficulties or complex medication regimens in order to improve the utility of the system. Future research should also identify characteristics of medication users who are more likely to be receptive to IVR technology.</p

    Organotypic Culture of Physiologically Functional Adult Mammalian Retinas

    Get PDF
    BACKGROUND: The adult mammalian retina is an important model in research on the central nervous system. Many experiments require the combined use of genetic manipulation, imaging, and electrophysiological recording, which make it desirable to use an in vitro preparation. Unfortunately, the tissue culture of the adult mammalian retina is difficult, mainly because of the high energy consumption of photoreceptors. METHODS AND FINDINGS: We describe an interphase culture system for adult mammalian retina that allows for the expression of genes delivered to retinal neurons by particle-mediated transfer. The retinas retain their morphology and function for up to six days— long enough for the expression of many genes of interest—so that effects upon responses to light and receptive fields could be measured by patch recording or multielectrode array recording. We show that a variety of genes encoding pre- and post-synaptic marker proteins are localized correctly in ganglion and amacrine cells. CONCLUSIONS: In this system the effects on neuronal function of one or several introduced exogenous genes can be studied within intact neural circuitry of adult mammalian retina. This system is flexible enough to be compatible with genetic manipulation, imaging, cell transfection, pharmacological assay, and electrophysiological recordings
    corecore