2,577 research outputs found
Adverse Health Effects of Spousal Violence Among Women Attending Saudi Arabian Primary Health-Care Clinics
This study aimed to investigate the frequency of spousal violence among Saudi women and document the related health effects and injuries, as well as their attitudes to gender and violence. Structured interviews were conducted with 200 ever-married women recruited from primary-care centres in Jeddah. Nearly half of the surveyed women (44.5%) reported ever experiencing physical violence from their spouse. Although 37 women (18.5%) had received violence-related injuries, only 6.5% had reported these injuries to a health-care provider. Victims of spousal violence had poor perceptions of their overall health, and reported pain or discomfort, antidepressant use and suicidal thoughts. Women mostly disagreed with the presented justifications for wife beating. However, the association between gender attitudes and spousal violence was not significant. The results of this study support calls for integration of education about partner violence into health care curricula to enhance the access and quality of services
Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging
Recently CMOS Active Pixels Sensors (APSs) have become a valuable alternative to amorphous Silicon and Selenium Flat Panel Imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ≤ 1.9%. The uniformity of the image quality performance has been further investigated in a typical X-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practise. Finally, in order to compare the detection capability of this novel APS with the currently used technology (i.e. FPIs), theoretical evaluation of the Detection Quantum Efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, X-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications
Effects of 3-Weeks of High-Intensity Interval Training on Running Economy and Endurance
Please view abstract in the attached PDF fil
Valuing Ecosystem Services in Semi-arid Rangelands through Stochastic Simulation
Ecosystem services and economic returns from semi-arid rangelands are threatened by land degradation. Policies to improve ecosystem service delivery often fail to consider uncertainty in economic returns gained through different land uses and management practices. We apply an analytical framework using stochastic simulation to estimate the range of potential monetary outcomes of rangeland ecosystem services under different land uses, including consideration of the uncertainty and variability of model parameters. We assess monetary and non-monetary dimensions, including those ecosystem services with uncertain and missing information, for communal rangelands, commercial ranches, game farms and Wildlife Management Areas in southern Kgalagadi District, Botswana. Public land uses (communal grazing areas and protected conservation land in Wildlife Management Areas) provide higher economic value than private land uses (commercial ranches and game farms), despite private land uses being more profitable in their returns from meat production. Communal rangelands and protected areas are important for a broader range of ecosystem services (cultural/spiritual services, recreation, firewood, construction material and wild food), which play a key role in sustaining the livelihoods of the largest share of society. The full range of ecosystem services should therefore be considered in economic assessments, while policies targeting sustainable land management should value and support their provision and utilisation. By forecasting the range of plausible ecosystem values of different rangeland land uses in monetary terms, our analysis provides policymakers with a tool to assess outcomes of land use and management decisions and policies
Epidural Hematoma Following Cervical Spine Surgery.
STUDY DESIGN: A multicentered retrospective case series.
OBJECTIVE: To determine the incidence and circumstances surrounding the development of a symptomatic postoperative epidural hematoma in the cervical spine.
METHODS: Patients who underwent cervical spine surgery between January 1, 2005, and December 31, 2011, at 23 institutions were reviewed, and all patients who developed an epidural hematoma were identified.
RESULTS: A total of 16 582 cervical spine surgeries were identified, and 15 patients developed a postoperative epidural hematoma, for a total incidence of 0.090%. Substantial variation between institutions was noted, with 11 sites reporting no epidural hematomas, and 1 site reporting an incidence of 0.76%. All patients initially presented with a neurologic deficit. Nine patients had complete resolution of the neurologic deficit after hematoma evacuation; however 2 of the 3 patients (66%) who had a delay in the diagnosis of the epidural hematoma had residual neurologic deficits compared to only 4 of the 12 patients (33%) who had no delay in the diagnosis or treatment (P = .53). Additionally, the patients who experienced a postoperative epidural hematoma did not experience any significant improvement in health-related quality-of-life metrics as a result of the index procedure at final follow-up evaluation.
CONCLUSION: This is the largest series to date to analyze the incidence of an epidural hematoma following cervical spine surgery, and this study suggest that an epidural hematoma occurs in approximately 1 out of 1000 cervical spine surgeries. Prompt diagnosis and treatment may improve the chance of making a complete neurologic recovery, but patients who develop this complication do not show improvements in the health-related quality-of-life measurements
Nonequilibrium effects in DNA microarrays: a multiplatform study
It has recently been shown that in some DNA microarrays the time needed to
reach thermal equilibrium may largely exceed the typical experimental time,
which is about 15h in standard protocols (Hooyberghs et al. Phys. Rev. E 81,
012901 (2010)). In this paper we discuss how this breakdown of thermodynamic
equilibrium could be detected in microarray experiments without resorting to
real time hybridization data, which are difficult to implement in standard
experimental conditions. The method is based on the analysis of the
distribution of fluorescence intensities I from different spots for probes
carrying base mismatches. In thermal equilibrium and at sufficiently low
concentrations, log I is expected to be linearly related to the hybridization
free energy with a slope equal to , where is
the experimental temperature and R is the gas constant. The breakdown of
equilibrium results in the deviation from this law. A model for hybridization
kinetics explaining the observed experimental behavior is discussed, the
so-called 3-state model. It predicts that deviations from equilibrium yield a
proportionality of to . Here, is an
effective temperature, higher than the experimental one. This behavior is
indeed observed in some experiments on Agilent arrays. We analyze experimental
data from two other microarray platforms and discuss, on the basis of the
results, the attainment of equilibrium in these cases. Interestingly, the same
3-state model predicts a (dynamical) saturation of the signal at values below
the expected one at equilibrium.Comment: 27 pages, 9 figures, 1 tabl
An mRNA processing pathway suppresses metastasis by governing translational control from the nucleus
Cancer cells often co-opt post-transcriptional regulatory mechanisms to achieve pathologic expression of gene networks that drive metastasis. Translational control is a major regulatory hub in oncogenesis; however, its effects on cancer progression remain poorly understood. Here, to address this, we used ribosome profiling to compare genome-wide translation efficiencies of poorly and highly metastatic breast cancer cells and patient-derived xenografts. We developed dedicated regression-based methods to analyse ribosome profiling and alternative polyadenylation data, and identified heterogeneous nuclear ribonucleoprotein C (HNRNPC) as a translational controller of a specific mRNA regulon. We found that HNRNPC is downregulated in highly metastatic cells, which causes HNRNPC-bound mRNAs to undergo 3′ untranslated region lengthening and, subsequently, translational repression. We showed that modulating HNRNPC expression impacts the metastatic capacity of breast cancer cells in xenograft mouse models. In addition, the reduced expression of HNRNPC and its regulon is associated with the worse prognosis in breast cancer patient cohorts
Observations of the 6 Centimeter Lines of OH in Evolved (OH/IR) Stars
Recent observational and theoretical advances have called into question
traditional OH maser pumping models in evolved (OH/IR) stars. The detection of
excited-state OH lines would provide additional constraints to discriminate
amongst these theoretical models. In this Letter, we report on VLA observations
of the 4750 MHz and 4765 MHz lines of OH toward 45 sources, mostly evolved
stars. We detect 4765 MHz emission in the star forming regions Mon R2 and LDN
1084, but we do not detect excited-state emission in any evolved stars. The
flux density and velocity of the 4765 MHz detection in Mon R2 suggests that a
new flaring event has begun.Comment: 4 pages, to appear in ApJ
C5 Palsy After Cervical Spine Surgery: A Multicenter Retrospective Review of 59 Cases.
STUDY DESIGN: A multicenter, retrospective review of C5 palsy after cervical spine surgery.
OBJECTIVE: Postoperative C5 palsy is a known complication of cervical decompressive spinal surgery. The goal of this study was to review the incidence, patient characteristics, and outcome of C5 palsy in patients undergoing cervical spine surgery.
METHODS: We conducted a multicenter, retrospective review of 13 946 patients across 21 centers who received cervical spine surgery (levels C2 to C7) between January 1, 2005, and December 31, 2011, inclusive. P values were calculated using 2-sample t test for continuous variables and χ(2) tests or Fisher exact tests for categorical variables.
RESULTS: Of the 13 946 cases reviewed, 59 patients experienced a postoperative C5 palsy. The incidence rate across the 21 sites ranged from 0% to 2.5%. At most recent follow-up, 32 patients reported complete resolution of symptoms (54.2%), 15 had symptoms resolve with residual effects (25.4%), 10 patients did not recover (17.0%), and 2 were lost to follow-up (3.4%).
CONCLUSION: C5 palsy occurred in all surgical approaches and across a variety of diagnoses. The majority of patients had full recovery or recovery with residual effects. This study represents the largest series of North American patients reviewed to date
Radiometer Calibration Using Colocated GPS Radio Occultation Measurements
We present a new high-fidelity method of calibrating a cross-track scanning microwave radiometer using Global Positioning System (GPS) radio occultation (GPSRO) measurements. The radiometer and GPSRO receiver periodically observe the same volume of atmosphere near the Earth's limb, and these overlapping measurements are used to calibrate the radiometer. Performance analyses show that absolute calibration accuracy better than 0.25 K is achievable for temperature sounding channels in the 50-60-GHz band for a total-power radiometer using a weakly coupled noise diode for frequent calibration and proximal GPSRO measurements for infrequent (approximately daily) calibration. The method requires GPSRO penetration depth only down to the stratosphere, thus permitting the use of a relatively small GPS antenna. Furthermore, only coarse spacecraft angular knowledge (approximately one degree rms) is required for the technique, as more precise angular knowledge can be retrieved directly from the combined radiometer and GPSRO data, assuming that the radiometer angular sampling is uniform. These features make the technique particularly well suited for implementation on a low-cost CubeSat hosting both radiometer and GPSRO receiver systems on the same spacecraft. We describe a validation platform for this calibration method, the Microwave Radiometer Technology Acceleration (MiRaTA) CubeSat, currently in development for the National Aeronautics and Space Administration (NASA) Earth Science Technology Office. MiRaTA will fly a multiband radiometer and the Compact TEC/Atmosphere GPS Sensor in 2015
- …