239 research outputs found

    Long-term performance of enhanced-zero valent iron for drinking water treatment: a lab-scale study

    Get PDF
    Former studies have shown that enhanced-zero valent iron (ZVI) could effectively remove various contaminants. The present study evaluates for the first time the long-term performance of enhanced-ZVI to remove natural organic matter (NOM), an important water quality parameter in drinking water. Lab-scale flow-through experiments showed that averagely 7–14% dissolved organic carbon (DOC) and 6–15% ultraviolet absorbance at 254\ua0nm (UV) reduction could be achieved by enhanced-ZVI in the first 10,000 bed volumes filtration when a 0.36 or 1.8\ua0mins empty bed contact time (EBCT) was applied. After 10,000-bed volumes, the enhanced-ZVI bed became passivated. However, sulphuric acid was able to regenerate the passivated enhanced-ZVI bed, recover the capacity of enhanced-ZVI in removing NOM, and hence make the best use of the available ZVI. The acidic rinsing solution containing dissolved iron was suitable as a supplemental source of iron for coagulation. In addition, during the long-term experiments, the biofilters following enhanced-ZVI (1.8\ua0min EBCT) removed more NOM than biofilters without any pre-treatment. This could be explained by the formation of biodegradable organic matter (BDOC) during the enhanced-ZVI process and the precipitation of iron in the biofilters. Based on these findings, a novel water treatment train, incorporating enhanced-ZVI with periodical regeneration, biofiltration, and coagulation, was proposed and evaluated

    Biodegradability of DBP precursors after drinking water ozonation

    Get PDF
    Ozonation is known to generate biodegradable organic matter, which is typically reduced by biological filtration to avoid bacterial regrowth in distribution systems. Post-chlorination generates halogenated disinfection byproducts (DBPs) but little is known about the biodegradability of their precursors. This study determined the effect of ozonation and biofiltration conditions, specifically ozone exposure and empty bed contact time (EBCT), on the control of DBP formation potentials in drinking water. Ozone exposure was varied through addition of H2O2 during ozonation at 1 mgO3/mgDOC followed by biological filtration using either activated carbon (BAC) or anthracite. Ozonation led to a 10% decrease in dissolved organic carbon (DOC), without further improvement from H2O2 addition. Raising H2O2 concentrations from 0 to 2 mmol/mmolO3 resulted in increased DBP formation potentials during post-chlorination of the ozonated water (target Cl2 residual after 24\ua0h\ua0=\ua01-2\ua0mg/L) as follows: 4 trihalomethanes (THM4, 37%), 8 haloacetic acids (HAA8, 44%), chloral hydrate (CH, 107%), 2 haloketones (HK2, 97%), 4 haloacetonitriles (HAN4, 33%), trichloroacetamide (TCAM, 43%), and adsorbable organic halogen (AOX, 27%), but a decrease in the concentrations of 2 trihalonitromethanes (THNM2, 43%). Coupling ozonation with biofiltration prior to chlorination effectively lowered the formation potentials of all DBPs including CH, HK2, and THNM2, all of which increased after ozonation. The dynamics of DBP formation potentials during BAC filtration at different EBCTs followed first-order reaction kinetics. Minimum steady-state concentrations were attained at an EBCT of about 10-20\ua0min, depending on the DBP species. The rate of reduction in DBP formation potentials varied among individual species before reaching their minimum concentrations. CH, HK2, and THNM2 had the highest rate constants of between 0.5 and 0.6 min(-1) followed by HAN4 (0.4 min(-1)), THM4 (0.3 min(-1)), HAA8 (0.2 min(-1)), and AOX (0.1 min(-1)). At an EBCT of 15\ua0min, the reduction in formation potential for most DBPs was less than 50% but was higher than 70% for CH, HK2, and THNM2. The formation of bromine-containing DBPs increased with increasing EBCT, most likely due to an increase in Br(-)/DOC ratio. Overall, this study demonstrated that the combination of ozonation and biofiltration is an effective approach to mitigate DBP formation during drinking water treatment

    Biological phosphorus removal from abattoir wastewater at very short sludge ages mediated by novel PAO clade Comamonadaceae

    Get PDF
    Recent increases in global phosphorus costs, together with the need to remove phosphorus from wastewater to comply with water discharge regulations, make phosphorus recovery from wastewater economically and environmentally attractive. Biological phosphorus (Bio-P) removal process can effectively capture the phosphorus from wastewater and concentrate it in a form that is easily amendable for recovery in contrast to traditional (chemical) phosphorus removal processes. However, Bio-P removal processes have historically been operated at medium to long solids retention times (SRTs, 10-20 days typically), which inherently increases the energy consumption while reducing the recoverable carbon fraction and hence makes it incompatible with the drive towards energy self-sufficient wastewater treatment plants. In this study, a novel high-rate Bio-P removal process has been developed as an energy efficient alternative for phosphorus removal from wastewater through operation at an SRT of less than 4 days. The process was most effective at an SRT of 2-2.5 days, achieving >90% phosphate removal. Further reducing the SRT to 1.7 days resulted in a loss of Bio-P activity. 16S pyrotag sequencing showed the community changed considerably with changes in the SRT, but that Comamonadaceae was consistently abundant when the Bio-P activity was evident. FISH analysis combined with DAPI staining confirmed that bacterial cells of Comamonadaceae arranged in tetrads contained polyphosphate, identifying them as the key polyphosphate accumulating organisms at these low SRT conditions. Overall, this paper demonstrates a novel, high-rate phosphorus removal process that can be effectively integrated with short SRT, energy-efficient carbon removal and recovery processes

    Impact of fluctuations in gaseous H2S concentrations on sulfide uptake by sewer concrete: The effect of high H2S loads

    Get PDF
    The acid production from the oxidation of hydrogen sulfide (H2S) in sewer air results in serious corrosion of exposed concrete surfaces in sewers. Large fluctuations of gaseous H2S concentrations occur in sewers due to the diurnal profiles of sewage flow and retention times and the necessity of intermittent pumping of sewage from pressure pipes into gravity pipes. How the high concentrations of H2S due to these events may affect H2S uptake and subsequent corrosion by concrete sewers is largely unknown. This study determined the effect of short- and long-term increases in H2S levels on the sulfide uptake rate (SUR) of concrete surfaces with an active corrosion layer. The results showed that during the high load situation the SUR increased significantly but then decreased (compared to the baseline SUR) by about 7-14% and 41-50% immediately after short- and long-term H2S high-load periods, respectively. For both exposure conditions, the SUR gradually (over several hours) recovered to approximately 90% of the baseline SUR. Further tests suggest multiple factors may contribute to the observed decrease of SUR directly after the high H2S load. This includes the temporary storage of elemental sulfur in the corrosion layer and inhibition of sulfide oxidizing bacteria (SOB) due to high H2S level and temporary acid surge. Additionally, the delay of the corrosion layer to fully recover the SUR after the high H2S load suggests that there is a longer-term inhibitive effect of the high H2S levels on the activity of the SOB in the corrosion layer. Due to the observed activity reductions, concrete exposed to occasional short-term high H2S load periods had an overall lower H2S uptake compared to concrete exposed to constant H2S levels at the same average concentration. To accurately predict H2S uptake by sewer concrete and hence the likely maximum corrosion rates, a correction factor should be adopted for the H2S fluctuations when average H2S levels are used in the prediction. (C) 2015 Elsevier Ltd. All rights reserved

    Identification of controlling factors for the initiation of corrosion of fresh concrete sewers

    Get PDF
    The development of concrete corrosion in new sewer pipes undergoes an initiation process before reaching an active corrosion stage. This initiation period is assumed to last several months to years but the key factors affecting the process, and its duration, are not well understood. This study is therefore focused on this initial stage of the corrosion process and the effect of key environmental factors. Such knowledge is important for the effective management of corrosion in new sewers, as every year of life extension of such systems has a very high financial benefit. This long-term (4.5 year) study has been conducted in purpose-built corrosion chambers that closely simulated the sewer environment, but with control of three key environmental factors being hydrogen sulfide (H2S) gas phase concentration, relative humidity and air temperature. Fresh concrete coupons, cut from an industry-standard sewer pipe, were exposed to the corrosive conditions in the chambers, both in the gas phase and partially submerged in wastewater. A total of 36 exposure conditions were investigated to determine the controlling factors by regular retrieval of concrete coupons for detailed analysis of surface pH, sulfur compounds (elemental sulfur and sulfate) and concrete mass loss. Corrosion initiation times were thus determined for different exposure conditions. It was found that the corrosion initiation time of both gas-phase and partially-submerged coupons was positively correlated with the gas phase H2S concentration, but only at levels of 10 ppm or below, indicating that sulfide oxidation rate rather than the H2S concentration was the limiting factor during the initiation stage. Relative humidity also played a role for the corrosion initiation of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as these coupons were in direct contact with the sewage and hence did have sufficient moisture to enable the microbial processes to proceed. The corrosion initiation time was also shortened by higher gas temperature due to its positive impact on reaction kinetics. These findings provide real opportunities for pro-active sewer asset management with the aim to delay the on-set of the corrosion processes, and hence extend the service life of sewers, through improved prediction and optimization capacity. (C) 2015 Elsevier Ltd. All rights reserved

    A novel carbon nanotube modified scaffold as an efficient biocathode material for improved microbial electrosynthesis

    Get PDF
    We report on a novel biocompatible, highly conductive three-dimensional cathode manufactured by direct growth of flexible multiwalled carbon nanotubes on reticulated vitreous carbon (NanoWeb-RVC) for the improvement of microbial bioelectrosynthesis (MES). NanoWeb-RVC allows for an enhanced bacterial attachment and biofilm development within its hierarchical porous structure. 1.7 and 2.6 fold higher current density and acetate bioproduction rate normalized to total surface area were reached on NanoWeb-RVC versus a carbon plate control for the microbial reduction of carbon dioxide by mixed cultures. This is the first study showing better intrinsic efficiency as biocathode material of a three-dimensional electrode versus a flat electrode: this comparison has been made considering the total surface area of the porous electrode, and not just the projected surface area. Therefore, the improved performance is attributed to the nanostructure of the electrode and not to an increase in surface area. Unmodified reticulated vitreous carbon electrodes lacking the nanostructure were found unsuitable for MES, with no biofilm development and no acetate production detected. The high surface area to volume ratio of the macroporous RVC maximizes the available biofilm area while ensuring effective mass transfer to and from the biofilm. The nanostructure enhances the bacteria-electrode interaction and microbial extracellular electron transfer. When normalized to projected surface area, current densities and acetate production rates of 3.7 mA cm-2 and 1.3 mM cm-2 d-1, respectively, were reached, making the NanoWeb-RVC an extremely efficient material from an engineering perspective as well. These values are the highest reported for any MES system to date
    • …
    corecore