10 research outputs found

    Signal to noise ratio of upgraded imaging bolometer for KSTAR

    Get PDF
    An InfraRed imaging Video Bolometer (IRVB) was installed on KSTAR in 2012 having a ∼2 μm × 7 cm × 9 cm Pt foil blackened with graphite and a 5 mm × 5 mm aperture located 7.65 cm from the foil with 16 × 12 channels and a time resolution of 10 ms. The IR camera was an Indigo Phoenix (InSb, 320 × 256 pixels, 435 fps, <25 mK). In 2017, the IRVB was upgraded by replacing the IR camera with a FLIR SC7600 (InSb, 640 × 512 pixels, 105 fps, <25 mK). The aperture area was reduced by approximately half to 3.5 mm × 3.5 mm, and the number of channels was quadrupled to 32 × 24. A synthetic image derived using the projection matrix for the upgraded IRVB from a Scrape Off Layer Plasma Simulator (SOLPS) model with 146 kW of total radiated power had a maximum signal of 7.6 W/m2 and a signal to noise ratio (SNR) of 11. Experimental data for a plasma with parameters similar to the SOLPS model (total radiated power of 158 kW) had a maximum signal of 12.6 W/m2 and noise equivalent power density (SNR) of 0.9 W/m2 (14)

    Modification of argon impurity transport by electron cyclotron heating in KSTAR H-mode plasmas

    Get PDF
    Experiments with a small amount of Ar gas injection as a trace impurity were conducted in the Korea Superconducting Tokamak Advanced Research (KSTAR) H-mode plasma (BT  = 2.8 T, IP = 0.6 MA, and PNBI = 4.0 MW). 170 GHz electron cyclotron resonance heating (ECH) at 600 and 800 kW was focused along the mid-plane with a fixed major radial position of R  =  1.66 m. The emissivity of the Ar16+ (3.949 Å) and Ar15+ (353.860 Å) spectral lines were measured by x-ray imaging crystal spectroscopy (XICS) and a vacuum UV (VUV) spectrometer, respectively. ECH reduces the peak Ar15+ emission and increases the Ar16+ emission, an effect largest with 800 kW. The ADAS-SANCO impurity transport code was used to evaluate the Ar transport coefficients. It was found that the inward convective velocity found in the plasma core without ECH was decreased with ECH, while diffusion remained approximately constant resulting in a less-peaked Ar density profile. Theoretical results from the NEO code suggest that neoclassical transport is not responsible for the change in transport, while the microstability analysis using GKW predicts a dominant ITG mode during both ECH and non-ECH plasmas

    PAFモデルのサービス業への適用に関する研究 : 新たなフレームワークの提案と宿泊業を対象とした定量的検証

    Get PDF
    博士(商学)12613甲第874号[1], iii, 101p一橋大

    Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

    No full text
    Design and development of the ITER divertor VUV spectrometer have been performed from the year 1998, and it is planned to be installed in the year 2027. Currently, the design of the ITER divertor VUV spectrometer is in the phase of detail design. It is optimized for monitoring of chord-integrated VUV signals from divertor plasmas, chosen to contain representative lines emission from the tungsten as the divertor material, and other impurities. Impurity emission from overall divertor plasmas is collimated through the relay optics onto the entrance slit of a VUV spectrometer with working wavelength range of 14.6–32 nm. To validate the design of the ITER divertor VUV spectrometer, two sets of VUV spectrometers have been developed and tested at KSTAR tokamak. One set of spectrometer without the field mirror employs a survey spectrometer with the wavelength ranging from 14.6 nm to 32 nm, and it provides the same optical specification as the spectrometer part of the ITER divertor VUV spectrometer system. The other spectrometer with the wavelength range of 5–25 nm consists of a commercial spectrometer with a concave grating, and the relay mirrors with the same geometry as the relay mirrors of the ITER divertor VUV spectrometer. From test of these prototypes, alignment method using backward laser illumination could be verified. To validate the feasibility of tungsten emission measurement, furthermore, the tungsten powder was injected in KSTAR plasmas, and the preliminary result could be obtained successfully with regard to the evaluation of photon throughpu

    Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

    No full text
    Design and development of the ITER divertor VUV spectrometer have been performed from the year 1998, and it is planned to be installed in the year 2027. Currently, the design of the ITER divertor VUV spectrometer is in the phase of detail design. It is optimized for monitoring of chord-integrated VUV signals from divertor plasmas, chosen to contain representative lines emission from the tungsten as the divertor material, and other impurities. Impurity emission from overall divertor plasmas is collimated through the relay optics onto the entrance slit of a VUV spectrometer with working wavelength range of 14.6–32 nm. To validate the design of the ITER divertor VUV spectrometer, two sets of VUV spectrometers have been developed and tested at KSTAR tokamak. One set of spectrometer without the field mirror employs a survey spectrometer with the wavelength ranging from 14.6 nm to 32 nm, and it provides the same optical specification as the spectrometer part of the ITER divertor VUV spectrometer system. The other spectrometer with the wavelength range of 5–25 nm consists of a commercial spectrometer with a concave grating, and the relay mirrors with the same geometry as the relay mirrors of the ITER divertor VUV spectrometer. From test of these prototypes, alignment method using backward laser illumination could be verified. To validate the feasibility of tungsten emission measurement, furthermore, the tungsten powder was injected in KSTAR plasmas, and the preliminary result could be obtained successfully with regard to the evaluation of photon throughpu
    corecore