23 research outputs found

    Right Turn Veteran-Specific Recovery Service: 5 site evaluation pilot : Interim report

    Get PDF
    The Right Turn project works with the ex-service personnel community in recovery from substance misuse. This report presents the interim findings from a two-year evaluation on the impact on health and wellbeing outcomes on military veterans engaging in this innovative peer-focussed recovery service. The evaluation is designed around a structured quantitative data collection process using an established repeat measure design and utilises qualitative methodologies to explore both the life experiences of this veteran cohort and to take account of their own perceptions of the model of services they feel they require. This report suggests that the military veteran community experience distinct barriers to accessing main stream health and wellbeing services. Alongside comorbidity issues, management of chronic physical conditions and social isolation, this report demonstrates that this cohort's own previous military conditioning forms a further barrier to accessing support services. This report contains recommendations to inform generic support staff when encountering veterans within health and wellbeing settings

    Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol.

    Get PDF
    INTRODUCTION: Closed-loop systems titrate insulin based on sensor glucose levels, providing novel means to reduce the risk of hypoglycaemia while improving glycaemic control. We will assess effectiveness of 6-month day-and-night closed-loop insulin delivery compared with usual care (conventional or sensor-augmented pump therapy) in children and adolescents with type 1 diabetes. METHODS AND ANALYSIS: The trial adopts an open-label, multicentre, multinational (UK and USA), randomised, single-period, parallel design. Participants (n=130) are children and adolescents (aged ≥6 and 16.7 mmol/L (300 mg/dL), area under the curve of glucose >10.0 mmol/L (180 mg/dL), total, basal and bolus insulin dose, body mass index z-score and blood pressure. Cognitive, emotional and behavioural characteristics of participants and caregivers and their responses to the closed-loop and clinical trial will be assessed. An incremental cost-effectiveness ratio for closed-loop will be estimated. ETHICS AND DISSEMINATION: Cambridge South Research Ethics Committee and Jaeb Center for Health Research Institutional Review Office approved the study. The findings will be disseminated by peer-review publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT02925299; Pre-results

    WormAssay: A Novel Computer Application for Whole-Plate Motion-based Screening of Macroscopic Parasites

    Get PDF
    Lymphatic filariasis is caused by filarial nematode parasites, including Brugia malayi. Adult worms live in the lymphatic system and cause a strong immune reaction that leads to the obstruction of lymph vessels and swelling of the extremities. Chronic disease leads to the painful and disfiguring condition known as elephantiasis. Current drug therapy is effective against the microfilariae (larval stage) of the parasite, but no drugs are effective against the adult worms. One of the major stumbling blocks toward developing effective macrofilaricides to kill the adult worms is the lack of a high throughput screening method for candidate drugs. Current methods utilize systems that measure one well at a time and are time consuming and often expensive. We have developed a low-cost and simple visual imaging system to automate and quantify screening entire plates based on parasite movement. This system can be applied to the study of many macroparasites as well as other macroscopic organisms

    Predictive Low-Glucose Insulin Suspension Reduces Duration of Nocturnal Hypoglycemia in Children Without Increasing Ketosis

    No full text
    OBJECTIVE: Nocturnal hypoglycemia can cause seizures and is a major impediment to tight glycemic control, especially in young children with type 1 diabetes. We conducted an in-home randomized trial to assess the efficacy and safety of a continuous glucose monitor–based overnight predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS: In two age-groups of children with type 1 diabetes (11–14 and 4–10 years of age), a 42-night trial for each child was conducted wherein each night was assigned randomly to either having the PLGS system active (intervention night) or inactive (control night). The primary outcome was percent time <70 mg/dL overnight. RESULTS: Median time at <70 mg/dL was reduced by 54% from 10.1% on control nights to 4.6% on intervention nights (P < 0.001) in 11–14-year-olds (n = 45) and by 50% from 6.2% to 3.1% (P < 0.001) in 4–10-year-olds (n = 36). Mean overnight glucose was lower on control versus intervention nights in both age-groups (144 ± 18 vs. 152 ± 19 mg/dL [P < 0.001] and 153 ± 14 vs. 160 ± 16 mg/dL [P = 0.004], respectively). Mean morning blood glucose was 159 ± 29 vs. 176 ± 28 mg/dL (P < 0.001) in the 11–14-year-olds and 154 ± 25 vs. 158 ± 22 mg/dL (P = 0.11) in the 4–10-year-olds, respectively. No differences were found between intervention and control in either age-group in morning blood ketosis. CONCLUSIONS: In 4–14-year-olds, use of a nocturnal PLGS system can substantially reduce overnight hypoglycemia without an increase in morning ketosis, although overnight mean glucose is slightly higher
    corecore