51 research outputs found

    Immunomodulation Through Low-Dose Radiation for Severe COVID-19:Lessons From the Past and New Developments

    Get PDF
    Low-dose radiation therapy (LD-RT) has historically been a successful treatment for pneumonia and is clinically established as an immunomodulating therapy for inflammatory diseases. The ongoing COVID-19 pandemic has elicited renewed scientific interest in LD-RT and multiple small clinical trials have recently corroborated the historical LD-RT findings and demonstrated preliminary efficacy and immunomodulation for the treatment of severe COVID-19 pneumonia. The present review explicates archival medical research data of LD-RT and attempts to translate this into modernized evidence, relevant for the COVID-19 crisis. Additionally, we explore the putative mechanisms of LD-RT immunomodulation, revealing specific downregulation of proinflammatory cytokines that are integral to the development of the COVID-19 cytokine storm induced hyperinflammatory state. Radiation exposure in LD-RT is minimal compared to radiotherapy dosing standards in oncology care and direct toxicity and long-term risk for secondary disease are expected to be low. The recent clinical trials investigating LD-RT for COVID-19 confirm initial treatment safety. Based on our findings we conclude that LD-RT could be an important treatment option for COVID-19 patients that are likely to progress to severity. We advocate the further use of LD-RT in carefully monitored experimental environments to validate its effectiveness, risks and mechanisms of LD-RT

    The combined use of steroids and immune checkpoint inhibitors in brain metastasis patients:a systematic review and meta-analysis

    Get PDF
    BACKGROUND: Immune checkpoint inhibitors (ICI) have been a breakthrough for selected cancer patients, including those with brain metastases (BMs). Likewise, steroids have been an integral component of symptomatic management of BM patients. However, clinical evidence on the interaction between ICI and steroids in BM patients is conflicting and has not adequately been summarized thus far. Hence, the aim of this study was to perform a systematic literature review and meta-analysis on the association between steroid use and overall survival (OS) in BM patients receiving ICI. METHODS: A systematic literature search was performed. Pooled effect estimates were calculated using random-effects models across included studies. RESULTS: After screening 1145 abstracts, 15 observational studies were included. Fourteen studies reported sufficient data for meta-analysis, comprising 1102 BM patients of which 32.1% received steroids. In the steroid group, median OS ranged from 2.9 to 10.2 months. In the nonsteroid group, median OS ranged from 4.9 to 25.1 months. Pooled results demonstrated significantly worse OS (HR = 1.84, 95% CI 1.22-2.77) and systemic progression-free survival (PFS; HR = 2.00, 95% CI 1.37-2.91) in the steroid group. Stratified analysis showed a consistent effect across the melanoma subgroup; not in the lung cancer subgroup. No significant association was shown between steroid use and intracranial PFS (HR = 1.31, 95% CI 0.42-4.07). CONCLUSIONS: Administration of steroids was associated with significantly worse OS and PFS in BM patients receiving ICI. Further research on dose, timing, and duration of steroids is needed to elucidate the cause of this association and optimize outcomes in BM patients receiving ICI

    Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy

    Get PDF
    In brain/head-and-neck radiotherapy (RT), thermoplastic immobilization masks guarantee reproducible patient positioning in treatment position between MRI, CT, and irradiation. Since immobilization masks do not fit in the diagnostic MR head/head-and-neck coils, flexible surface coils are used for MRI imaging in clinical practice. These coils are placed around the head/neck, in contact with the immobilization masks. However, the positioning of these flexible coils is technician dependent, thus leading to poor image reproducibility. Additionally, flexible surface coils have an inferior signal-to-noise-ratio (SNR) compared to diagnostic coils. The aim of this work was to create a new immobilization setup which fits into the diagnostic MR coils in order to enhance MR image quality and reproducibility. For this purpose, a practical immobilization setup was constructed. The performances of the standard clinical and the proposed setups were compared with four tests: SNR, image quality, motion restriction, and reproducibility of inter-fraction subject positioning. The new immobilization setup resulted in 3.4 times higher SNR values on average than the standard setup, except directly below the flexible surface coils where similar SNR was observed. Overall, the image quality was superior for brain/head-and-neck images acquired with the proposed RT setup. Comparable motion restriction in feet-head/left-right directions (maximum motion ≈1 mm) and comparable inter-fraction repositioning accuracy (mean inter-fraction movement 1 ± 0.5 mm) were observed for the standard and the new setup

    Refining Critical Structure Contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark Results and Consensus Guidelines from the STOPSTORM.eu Consortium.

    Get PDF
    BACKGROUND AND PURPOSE In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS Centres within the STOPSTORM consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC=0.96, median MDA=0.1mm and median HD95=1.1mm) and aorta (median DSC=0.90, median MDA=0.1mm and median HD95=1.5mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC=0.83, median MDA=0.2mm and median HD95=0.5mm), valves (median DSC=0.16, median MDA=4.6mm and median HD95=16.0mm), coronary arteries (median DSC=0.4, median MDA=0.7mm and median HD95=8.3mm) and the sinoatrial and atrioventricular nodes (median DSC=0.29, median MDA=4.4mm and median HD95=11.4mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established

    Expression of the progenitor marker NG2/CSPG4 predicts poor survival and resistance to ionising radiation in glioblastoma

    Get PDF
    Glioblastoma (GBM) is a highly aggressive brain tumour, where patients respond poorly to radiotherapy and exhibit dismal survival outcomes. The mechanisms of radioresistance are not completely understood. However, cancer cells with an immature stem-like phenotype are hypothesised to play a role in radioresistance. Since the progenitor marker neuron-glial-2 (NG2) has been shown to regulate several aspects of GBM progression in experimental systems, we hypothesised that its expression would influence the survival of GBM patients. Quantification of NG2 expression in 74 GBM biopsies from newly diagnosed and untreated patients revealed that 50% express high NG2 levels on tumour cells and associated vessels, being associated with significantly shorter survival. This effect was independent of age at diagnosis, treatment received and hypermethylation of the O6-methylguanine methyltransferase (MGMT) DNA repair gene promoter. NG2 was frequently co-expressed with nestin and vimentin but rarely with CD133 and the NG2 positive tumour cells harboured genetic aberrations typical for GBM. 2D proteomics of 11 randomly selected biopsies revealed upregulation of an antioxidant, peroxiredoxin-1 (PRDX-1), in the shortest surviving patients. Expression of PRDX-1 was associated with significantly reduced products of oxidative stress. Furthermore, NG2 expressing GBM cells showed resistance to ionising radiation (IR), rapidly recognised DNA damage and effectuated cell cycle checkpoint signalling. PRDX-1 knockdown transiently slowed tumour growth rates and sensitised them to IR in vivo. Our data establish NG2 as an important prognostic factor for GBM patient survival, by mediating resistance to radiotherapy through induction of ROS scavenging enzymes and preferential DNA damage signalling

    Interobserver variability in target definition for stereotactic arrhythmia radioablation

    Get PDF
    BackgroundStereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR.MethodsDelineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient.ResultsTen electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02–0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52–1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51–1.55 cm, Dice-coefficient mean: 0.31 ± 0.21).ConclusionsInterobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation

    Imaging standardization in metastatic colorectal cancer : a joint EORTC-ESOI-ESGAR expert consensus recommendation

    Get PDF
    Background: Treatment monitoring in metastatic colorectal cancer (mCRC) relies on imaging to evaluate the tumor burden. Response Evaluation Criteria in Solid Tumors (RECIST) provide a framework on reporting and interpretation of imaging findings yet offer no guidance on a standardized imaging protocol tailored to mCRC patients. Imaging protocol heterogeneity remains a challenge for the reproducibility of conventional imaging endpoints and is an obstacle for research on novel imaging endpoints. Patients and methods: Acknowledging the recently highlighted potential of radiomics and artificial intelligence (AI) tools as decision support for patient care in mCRC, a multidisciplinary, international, and expert panel of imaging specialists was formed to find consensus on mCRC imaging protocols using the Delphi method. Results: Under the guidance of the European Organisation for Research and Treatment of Cancer (EORTC) Imaging and Gastrointestinal Tract Cancer Groups, the European Society of Oncologic Imaging (ESOI) and the European Society of Gastrointestinal and Abdominal Radiology (ESGAR), the EORTC-ESOI-ESGAR core imaging protocol was identified. Conclusion: This consensus protocol attempts to promote standardization and to diminish variations in patient preparation, scan acquisition and scan reconstruction. We anticipate that this standardization will increase reproducibility of radiomics and AI studies and serve as a catalyst for future research on imaging endpoints. For ongoing and future mCRC trials, we encourage principal investigators to support the dissemination of these imaging standards across recruiting centers.peer-reviewe

    Reproducibility of the gadolinium concentration measurements and of the fitting parameters of the vascular input function in the superior sagittal sinus in a patient population

    No full text
    It is widely recognised that the measurement of the arterial input function (AIF) is a key issue and a major source of errors in the pharmacokinetic modelling of dynamic, contrast-enhanced magnetic resonance imaging (DCE-MRI) data, and the modality of the AIF determination is still a matter of debate. In this study we addressed the problem of the intrinsic variability of the AIF within the imaged volume of a DCE-MRI scan by systematically investigating the change in the concentration of contrast agent over time and the fit parameters of the derived vascular input function (VIF) obtained from the superior sagittal sinus (SSS) of a patient population that was scanned longitudinally during treatment for high grade glioma. From a total of 82 scanning sessions, we compared the results obtained with three different DCE-MRI protocols and between two different fitting functions. We applied a correction algorithm to the measured concentration-time curves to minimize the effect of the low temporal resolution on the VIF, and investigated the effect of this algorithm on the reproducibility. Finally, where possible, we compared the signal obtained in the SSS to the signal obtained in the middle cerebral artery. We found a good intrapatient reproducibility of both the measured gadolinium concentrations and VIF parameters, and that the variation of the parameters due to slice location within a patient was significantly lower than the intra patient variation. Intrapatient, interscan differences were significantly less marked than inter-patient differences showing a good intraclass correlation coefficient. We did encounter a MRI protocol dependence of the VIF fitting parameters. The correction algorithm significantly improved the reproducibility of the fitting parameters. These results support the idea that the use of a patient specific measured AIF, not necessarily averaged over a large volume, offers a significant benefit with respect to an external AIF or a measured cohort average AIF. (C) 2010 Elsevier Inc. All rights reserve
    corecore