258 research outputs found

    Benefit From Directional Microphone Hearing Aids: Objective and Subjective Evaluations

    Get PDF
    ObjectivesThe aims of this study were to find and compare the effect of directional (DIR) processing of two different hearing aids via both subjective and objective methods, to determine the association between the results of the subjective and objective evaluations, and to find out individual predictive factors influencing the DIR benefit.MethodsTwenty-six hearing aid users fitted unilaterally with each two different experimental hearing aid performed modified Korean Hearing in Noise Test (K-HINT) in three DIR conditions; omnidirectional (OMNI) mode, OMNI plus noise reduction feature, fixed DIR mode. In order to determine benefits from DIR benefit within a hearing aid and compare performance of the DIR processing between hearing aids, a subjective questionnaire was administrated on speech quality (SQ) and discomfort in noise (DN) domain. Correlation analysis of factors influencing DIR benefit was accomplished.ResultsBenefits from switching OMNI mode to DIR mode within both hearing aids in K-HINT were about 2.8 (standard deviation, 3.5) and 2.1 dB SNR (signal to ratio; SD, 2.5), but significant difference in K-HINT results between OMNI and OMNI plus noise reduction algorithm was not shown. The subjective evaluation resulted in the better SQ and DN scores in DIR mode than those in OMNI mode. However, the difference of scores on both SQ and DN between the two hearing aids with DIR mode was not statistically significant. Any individual factors did not significantly affect subjective and objective DIR benefits.ConclusionDIR benefit was found not only in the objective measurement performed in the laboratory but also in the subjective questionnaires, but the subjective results was failed to have significant correlation with the DIR benefit obtained in the K-HINT. Factors influencing individual variation in perceptual DIR benefit were still hard to explain

    Long-term outcome of vertebral artery origin stenosis in patients with acute ischemic stroke

    Get PDF
    BACKGROUND: Vertebral artery origin (VAO) stenosis is occasionally observed in patients who have acute ischemic stroke. We investigated the long-term outcomes and clinical significance of VAO stenosis in patients with acute ischemic stroke. METHODS: We performed a prospective observational study using a single stroke center registry to investigate the risk of recurrent stroke and vascular outcomes in patients with acute ischemic stroke and VAO stenosis. To relate the clinical significance of VAO stenosis to the vascular territory of the index stroke, patients were classified into an asymptomatic VAO stenosis group and a symptomatic VAO stenosis group. RESULTS: Of the 774 patients who had acute ischemic stroke, 149 (19.3%) of them had more than 50% stenosis of the VAO. During 309 patient-years of follow-up (mean, 2.3 years), there were 7 ischemic strokes, 6 hemorrhagic strokes, and 2 unknown strokes. The annual event rates were 0.97% for posterior circulation ischemic stroke, 4.86% for all stroke, and 6.80% for the composite cardiovascular outcome. The annual event rate for ischemic stroke in the posterior circulation was significantly higher in patients who had symptomatic VAO stenosis than in patients who had asymptomatic stenosis (1.88% vs. 0%, p = 0.046). In a multivariate analysis, the hazard ratio, per one point increase of the Essen Stroke Risk Score (ESRS) for the composite cardiovascular outcome, was 1.46 (95% CI, 1.02-2.08, p = 0.036). CONCLUSIONS: Long-term outcomes of more than 50% stenosis of the VAO in patients with acute ischemic stroke were generally favorable. Additionally, ESRS was a predictor for the composite cardiovascular outcome. Asymptomatic VAO stenosis may not be a specific risk factor for recurrent ischemic stroke in the posterior circulation. However, VAO stenosis may require more clinical attention as a potential source of recurrent stroke when VAO stenosis is observed in patients who have concurrent ischemic stroke in the posterior circulation

    Nano-ilmenite FeTiO3 : synthesis and characterization

    Get PDF
    In general, ilmenite FeTiO3 is synthesized by solid-state reaction at very high pressure and high temperature. Synthesis of FeTiO3 is not an easy task as the Fe2+ ions are not stable. Therefore, it is really challenging to prepare this material. In this work nano-ilmenite FeTiO3 was synthesized by the sol-gel method. Structural, optical and magnetic characterizations were performed. The bandgap of FeTiO3 was determined to be 2.8 eV showing FeTiO3 as suitable wide bandgap material for technological applications. The FeTiO3 nanoparticles exhibit weak ferromagnetic properties at and below room temperature. The Neel temperature was observed to be around 52 K.Fundação para a Ciência e a Tecnologia (FCT

    Effects of Electrode Position on Spatiotemporal Auditory Nerve Fiber Responses: A 3D Computational Model Study

    Get PDF
    A cochlear implant (CI) is an auditory prosthesis that enables hearing by providing electrical stimuli through an electrode array. It has been previously established that the electrode position can influence CI performance. Thus, electrode position should be considered in order to achieve better CI results. This paper describes how the electrode position influences the auditory nerve fiber (ANF) response to either a single pulse or low- (250 pulses/s) and high-rate (5,000 pulses/s) pulse-trains using a computational model. The field potential in the cochlea was calculated using a three-dimensional finite-element model, and the ANF response was simulated using a biophysical ANF model. The effects were evaluated in terms of the dynamic range, stochasticity, and spike excitation pattern. The relative spread, threshold, jitter, and initiated node were analyzed for single-pulse response; and the dynamic range, threshold, initiated node, and interspike interval were analyzed for pulse-train stimuli responses. Electrode position was found to significantly affect the spatiotemporal pattern of the ANF response, and this effect was significantly dependent on the stimulus rate. We believe that these modeling results can provide guidance regarding perimodiolar and lateral insertion of CIs in clinical settings and help understand CI performance

    Effects of Early Surgical Exploration in Suspected Barotraumatic Perilymph Fistulas

    Get PDF
    ObjectivesTreatment of traumatic perilymph fistula (PLF) remains controversial between surgical repair and conservative therapy. The aim of this study is to analyze the outcomes of early surgical exploration in suspected barotraumatic PLF.MethodsNine patients (10 cases) who developed sudden sensorineural hearing loss and dizziness following barotrauma and underwent surgical exploration with the clinical impression of PLF were enrolled. Types of antecedent trauma, operative findings, control of dizziness after surgery, postoperative hearing outcomes, and relations to the time interval between traumatic event and surgery were assessed retrospectively.ResultsAll patients had sudden or progressive hearing loss and dizziness following trauma. Types of barotrauma were classified by the origin of the trauma: 4 external (car accident, slap injury) and 6 internal traumas (lifting, nasal blowing, straining). Surgical exploration was performed whenever PLF was suspected with the time interval of 2 to 47 days after the trauma. The possible evidence of PLF was found during surgery in 9 cases: a fibrous web around the oval window (n=3), fluid collection in the round window (RW; n=6) and bulging of the RW pseudomembrane (n=1). In every patient, vestibular symptoms disappeared immediately after surgery. The hearing was improved with a mean gain of 27.0±14.9 dB. When the surgical exploration was performed as early as less than 10 days after the trauma, serviceable hearing (≤40 dB) was obtained in 4 out of 7 cases (57.1%).ConclusionSudden or progressive sensorineural hearing loss accompanied by dizziness following barotrauma should prompt consideration of PLF. Early surgical exploration is recommended to improve hearing and vestibular symptoms

    Comparison of Clinico-Radiological Features between Congenital Cystic Neuroblastoma and Neonatal Adrenal Hemorrhagic Pseudocyst

    Get PDF
    OBJECTIVE: To evaluate the radiological and clinical findings of congenital cystic neuroblastomas as compared with those of the cystic presentation of neonatal adrenal hemorrhage. MATERIALS AND METHODS: We analyzed the US (n = 52), CT (n = 24), and MR (n = 4) images as well as the medical records of 28 patients harboring congenital cystic neuroblastomas (n = 16) and neonatal adrenal hemorrhagic pseudocysts (n = 14). The history of prenatal detection, location, size, presence of outer wall enhancement, internal septations, solid portion, calcification, turbidity, vascular flow on a Doppler examination, and evolution patterns were compared in two groups of cystic lesions, by Fischer's exact test. RESULTS: All (100%) neuroblastomas and three (21%) of the 14 hemorrhagic pseudocysts were detected prenatally. Both groups of cystic lesions occurred more frequently on the right side; 11 of 16 (69%) for neuroblastomas and 11 of 14 (79%) for hemorrhagic pseudocysts. The size, presence of solid portion, septum, enhancement, and turbidity did not differ significantly (p > 0.05) between the two groups of cystic lesions. However, tiny calcifications (n = 3) and vascular flow on color Doppler US (n = 3) were noted in only neuroblastomas. The cystic neuroblastomas became complex solid and cystic masses, and did not disappear for up to 90 days in the three following cases, whereas 11 of the 14 (79%) hemorrhagic pseudocysts disappeared completely and the three remaining (27%) evolved to calcifications only. CONCLUSION: Although the imaging findings of two groups of cystic lesions were similar, prenatal detection, the presence of calcification on initial images, vascularity on color Doppler US, and evolution to a more complex mass may all favor neuroblastomasope

    Comparison of Endoscopic Tympanoplasty to Microscopic Tympanoplasty

    Get PDF
    Objectives This study aimed to compare the outcome of endoscopic and microscopic tympanoplasty. Methods This was a retrospective comparative study of 73 patients (35 males and 38 females) who underwent type I tympanoplasty at Samsung Medical Center from April to December 2014. The subjects were classified into two groups; endoscopic tympanoplasty (ET, n=25), microscopic tympanoplasty (MT, n=48). Demographic data, perforation size of tympanic membrane at preoperative state, pure tone audiometric results preoperatively and 3 months postoperatively, operation time, sequential postoperative pain scale (NRS-11), and graft success rate were evaluated. Results The perforation size of the tympanic membrane in ET and MT group was 25.3%±11.7% and 20.1%±11.9%, respectively (P=0.074). Mean operation time of MT (88.9±28.5 minutes) was longer than that of the ET (68.2±22.1 minutes) with a statistical significance (P=0.002). External auditory canal (EAC) width was shorter in the ET group than in the MT group (P=0.011). However, EAC widening was not necessary in the ET group and was performed in 33.3% of patients in the MT group. Graft success rate in the ET and MT group were 100% and 95.8%, respectively; the values were not significantly different (P=0.304). Pre- and postoperative audiometric results including bone and air conduction thresholds and air-bone gap were not significantly different between the groups. In all groups, the postoperative air-bone gap was significantly improved compared to the preoperative air-bone gap. Immediate postoperative pain was similar between the groups. However, pain of 1 day after surgery was significantly less in the ET group. Conclusion With endoscopic system, minimal invasive tympanoplasty can be possible with similar graft success rate and less pain

    The C677 Mutation in Methylene Tetrahydrofolate Reductase Gene: Correlation with Uric Acid and Cardiovascular Risk Factors in Elderly Korean men

    Get PDF
    The C677T mutation in the methylene tetrahydrofolate reductase (MTHFR) gene results in elevated homocysteine levels and, presumably, in increased cardiovascular risk. Moreover, elevated homocysteine levels are reportedly associated with high serum uric acid levels. We evaluated the MTHFR genotype and a panel of biochemical, hematological variables, and lifestyle characteristics in 327 elderly Korean men (age range 40-81 yr; mean, 51.87). This study shows that mutation of the MTHFR gene may be a risk for hyperuricemia. The mean uric acid levels for the C/C, C/T and T/T genotypes were 5.54, 5.91 and 6.33 mg/dL, respectively (p=0.000). The T/T genotype was significantly more frequent in subjects with high uric acid levels (p=0.003). Thus, this mutation of the MTHFR gene is implied by the study results to be a risk factor of hyperuricemia in elderly Korean men. However, the relationship between the MTHFR mutation and uric acid metabolism remains unclear. Therefore, further studies are necessary to explain the associated between the MTHFR mutation and elevated uric acid levels, and to examine potential relationships between it and conventional cardiovascular risk factors
    corecore