99 research outputs found

    Comprehending the Aura between the hands

    Get PDF
    494-501This paper aimed to gain an understanding of aura between the hands and analyse the varied responses. Qualitative method, content analysis was used to analyse the written comments made by the participants, regarding aura between the hands, in a survey of students (N=47) from a college of complementary therapy. The results were analysed and 11 themes were identified. To name a few, a set of bioplasmic experiences, aura around the hand is an observable phenomenon, the aura has elastic property, aura experienced as a vibrational force. The themes have been analysed and discussed in detail. We conclude that viewing of the aura between the hands is a simple phenomenon and can be learned by almost anyone. Experimentation has led us to infer that, aura between the hands can be felt and seen

    Comprehending the Aura between the hands

    Get PDF
    This paper aimed to gain an understanding of aura between the hands and analyse the varied responses. Qualitative method, content analysis was used to analyse the written comments made by the participants, regarding aura between the hands, in a survey of students (N=47) from a college of complementary therapy. The results were analysed and 11 themes were identified. To name a few, a set of bioplasmic experiences, aura around the hand is an observable phenomenon, the aura has elastic property, aura experienced as a vibrational force. The themes have been analysed and discussed in detail. We conclude that viewing of the aura between the hands is a simple phenomenon and can be learned by almost anyone. Experimentation has led us to infer that, aura between the hands can be felt and seen

    Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

    Full text link
    The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 {\mu}eV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence

    Extended search for the invisible axion with the axion dark matter experiment

    Get PDF
    This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range 2.81–3.31μeV. This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics

    Search for invisible axion dark matter with the Axion Dark Matter Experiment

    Get PDF
    This Letter reports the results from a haloscope search for dark matter axions with masses between 2.66 and 2.81μeV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at subkelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultralow-noise superconducting quantum interference device amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses

    Study of cosmogenic activation above ground for the DarkSide-20k experiment

    Get PDF
    The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Despite the outstanding capability of discriminating / background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37Ar and 3H are shown not to be relevant due to short half-life and assumed purification methods

    Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

    Get PDF
    The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: 36Ar , 38Ar , and 40Ar . We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019

    An Embodied Approach in a Cognitive Discipline

    Get PDF
    Academia can be an uncomfortable place to work. Academics are examples of professionals who have multiple stresses and pressures. Being an academic is often a fundamental part of someone’s identity. Academia can be a cerebral, critical, competitive and judgmental environment. This chapter draws from a study using creative research methods with academics who self-identified as having an embodied practice. There are different definitions of embodiment. I use embodiment to mean both a state of being and a process of learning about the self, and so embodied practices are ways of bringing conscious self-awareness to and about the body. The academics reflected on the meanings they attributed to these embodied practices, tensions with their embodied identity, and how they used them to impact on their wellbeing

    Directionality of nuclear recoils in a liquid argon time projection chamber

    Full text link
    The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence levelComment: 20 pages, 10 figures, submitted to Eur. Phys. J.
    corecore