2 research outputs found

    Adherence with ethinylestradiol 20 µg/drospirenone 3 mg in a flexible extended regimen supported by the use of a digital tablet dispenser with or without acoustic alarm: an open-label, randomized, multicenter study

    No full text
    Objective: To evaluate the effect of a digital dispenser’s acoustic alarm function on adherence to ethinylestradiol (EE) 20 μg/drospirenone 3 mg in a flexible extended regimen (EE/drospirenoneFlex) among women in five European countries (France, Germany, Italy, Spain, UK) seeking oral contraception. Study design: Randomized, parallel-group open-label study. Methods: Women aged 18–35 years received EE/drospirenoneFlex administered in a regimen with cycle lengths of their choice with the aid of a digital pill dispenser over 1 year. In group A (N=250), the dispenser’s acoustic alarm was activated (ie, acoustic alarm + visual reminder). In group B (N=249), the acoustic alarm was deactivated (ie, visual reminder only). In addition, the women recorded pill intake daily in diary cards. The primary efficacy variable was the mean delay of daily pill release after the dispenser reminded the woman to take a pill (reference time). Secondary efficacy variables included number of missed pills, contraceptive efficacy, bleeding pattern, tolerability, and user satisfaction. Results: Dispenser data showed a mean (standard deviation [SD]) daily delay in pill release of 88 (126) minutes in group A vs 178 (140) minutes in group B (P,0.0001). Median (lower quartile, Q1; upper quartile, Q3) number of missed pills was 0 (0; 1) in group A vs 4 (1; 9) in group B (P,0.0001). Diary card results revealed similar trends; however, underreporting of missed pills was evident in both groups. No pregnancies were reported during 424 women-years of exposure. Across the two groups, the mean (SD) EE/drospirenoneFlex cycle length was 51.0 (31.8) days with strong regional differences, and the mean (SD) number of bleeding/spotting days was 50.4 (33.0) days. EE/drospirenoneFlex was well tolerated, and 80% of women were satisfied with treatment. Conclusion: The dispenser’s activated acoustic alarm improved adherence with daily tablet intake of EE/drospirenoneFlex, reducing missed pills. EE/drospirenoneFlex provided effective contraception and a good tolerability profile. Keywords

    Male hormonal contraception: a double-blind, placebo-controlled study.

    No full text
    Item does not contain fulltextBACKGROUND: This study was performed to assess spermatogenesis suppression and safety of a new combination of an etonogestrel (ENG) implant combined with testosterone undecanoate (TU) injections for male contraception. This is the first large placebo-controlled study for male hormonal contraception. DESIGN AND STUDY SUBJECTS: In this double-blind, multicenter study, we randomly assigned 354 healthy men to receive either a low- or high-release ENG implant sc combined with im TU injections (750 mg every 10 or 12 wk or 1000 mg every 12 wk) or placebo implant and injections. Treatment duration was 42 or 44 wk and posttreatment follow-up at least 24 wk. RESULTS: Overall, spermatogenesis was suppressed to 1 million/ml or less at wk 16 in 89% of men, with approximately 94% in two high-release ENG groups. Suppression was maintained up to the end of the treatment period in 91% of men. For all men who completed the treatment period, 3% never achieved 1 million/ml or less. Median recovery time to a sperm concentration above 20 million/ml was 15 wk (mean 17 wk, 95% confidence interval 16-18 wk). Treatment was well tolerated. As compared with the placebo group, more men in the active treatment groups reported adverse events such as weight gain, mood changes, acne, sweating, or libido change. For both spermatogenesis suppression and safety, differences were small between the active treatment groups. CONCLUSIONS: The combination of an ENG implant with TU injections is a well-tolerated male hormonal method, providing effective and reversible suppression of spermatogenesis. Although the results are good, there is still room for improvement, possibly by adjusting the dose regimen or changing the mode of application
    corecore