15 research outputs found

    Outcome-Affecting Parameters of Hip Arthroscopy for Femoroacetabular Impingement with Concomitant Cartilage Damage—Data Analysis from the German Cartilage Registry

    Get PDF
    This study aims to report on a prospectively collected, multicenter database of patients undergoing hip arthroscopy for femoroacetabular impingement syndrome (FAI) and concomitant cartilage damage (according to the International Cartilage Repair Society) and to assess the outcomeaffecting parameters. In the study, 353 hips with up to 24 months’ follow-up were assessed by iHOT-33 scoring and achievement of the minimal clinically important difference (MCID) and patient acceptable symptom state (PASS) levels. Multiple and binary regression analyses were performed to identify factors related to (un-) favorable outcomes and to assess their clinical relevance with regard to achieving the MCID and PASS. Multiple regression yielded the parameters of male sex (p = 0.022) and lower body mass index (BMI) (p = 0.019) at 6 months, lower BMI (p = 0.022) and younger age (p = 0.022) at 12 months, and younger age at 24 months (p = 0.039) to be significantly associated with higher iHOT scoring. Male sex (p = 0.019) and lower BMI (p = 0.018) were significantly correlated with achievement of the PASS in binary regression at 6 months, whereas at 12 (p = 0.010) and at 24 (p = 0.003) only younger age was shown to be significantly correlated. None of the parameters was statistically associated with achievement of the MCID. As the parameters of younger age, male sex, and lower BMI were identified as temporarily correlated with a preferable outcome in general and with achievement of the PASS in particular, these findings help to preoperatively identify factors associated with (un-) favorable therapy results

    Patients with Small Acetabular Cartilage Defects Caused by Femoroacetabular Impingement Do Not Benefit from Microfracture

    Get PDF
    Objective: According to current recommendations, large cartilage defects of the hip over 2 cm2 are suggested to undergo autologous chondrocyte transplantation (ACT), while small defects should be treated with microfracture. We investigated if patients with small chondral defects of the hip joint (≀100 mm2 ) actually benefit from microfracture. Design: In this retrospective multicenter cohort study 40 patients with focal acetabular cartilage defects smaller than 100 mm2 and of ICRS grade ≄2 caused by femoroacetabular impingement were included. Twenty-six unrandomized patients underwent microfracture besides treatment of the underlying pathology; in 14 patients cartilage lesions were left untreated during arthroscopy. Over a mean follow-up of 28.8 months patient-reported outcome was determined using the iHOT33 (international hip outcome tool) and the VAS (visual analog scale) for pain. Results: The untreated group showed a statistically significant improvement of the iHOT33 after 12 (p = 0.005), 24 (p = 0.019), and 36 months (p = 0.002) compared to the preoperative score, whereas iHOT33 in the microfracture group did not reveal statistically significant changes over time. There was no significant difference between both groups on any time point. Regarding pain both groups did not show a significant improvement over time in the VAS. Conclusion: The subjective outcome of patients with small cartilage defects of the hip (≀100 mm2 ) improves 12 months after arthroscopic FAIS surgery without any cartilage treatment. However, no improvement could be seen after microfracture. Therefore, a reserved surgical treatment for small cartilage defects of the hip under preservation of the subchondral bone is recommended especially if a simultaneous impingement correction is performed

    Patients with Small Acetabular Cartilage Defects Caused by Femoroacetabular Impingement Do Not Benefit from Microfracture

    Get PDF
    Objective: According to current recommendations, large cartilage defects of the hip over 2 cm2 are suggested to undergo autologous chondrocyte transplantation (ACT), while small defects should be treated with microfracture. We investigated if patients with small chondral defects of the hip joint (≀100 mm2) actually benefit from microfracture. Design: In this retrospective multicenter cohort study 40 patients with focal acetabular cartilage defects smaller than 100 mm2 and of ICRS grade ≄2 caused by femoroacetabular impingement were included. Twenty-six unrandomized patients underwent microfracture besides treatment of the underlying pathology; in 14 patients cartilage lesions were left untreated during arthroscopy. Over a mean follow-up of 28.8 months patient-reported outcome was determined using the iHOT33 (international hip outcome tool) and the VAS (visual analog scale) for pain. Results: The untreated group showed a statistically significant improvement of the iHOT33 after 12 (p = 0.005), 24 (p = 0.019), and 36 months (p = 0.002) compared to the preoperative score, whereas iHOT33 in the microfracture group did not reveal statistically significant changes over time. There was no significant difference between both groups on any time point. Regarding pain both groups did not show a significant improvement over time in the VAS. Conclusion: The subjective outcome of patients with small cartilage defects of the hip (≀100 mm2) improves 12 months after arthroscopic FAIS surgery without any cartilage treatment. However, no improvement could be seen after microfracture. Therefore, a reserved surgical treatment for small cartilage defects of the hip under preservation of the subchondral bone is recommended especially if a simultaneous impingement correction is performed

    Systematic Improvements in Transmon Qubit Coherence Enabled by Niobium Surface Encapsulation

    Full text link
    We present a novel transmon qubit fabrication technique that yields systematic improvements in T1_1 coherence times. We fabricate devices using an encapsulation strategy that involves passivating the surface of niobium and thereby preventing the formation of its lossy surface oxide. By maintaining the same superconducting metal and only varying the surface structure, this comparative investigation examining different capping materials and film substrates across different qubit foundries definitively demonstrates the detrimental impact that niobium oxides have on the coherence times of superconducting qubits, compared to native oxides of tantalum, aluminum or titanium nitride. Our surface-encapsulated niobium qubit devices exhibit T1_1 coherence times 2 to 5 times longer than baseline niobium qubit devices with native niobium oxides. When capping niobium with tantalum, we obtain median qubit lifetimes above 200 microseconds. Our comparative structural and chemical analysis suggests that amorphous niobium suboxides may induce higher losses. These results are in line with high-accuracy measurements of the niobium oxide loss tangent obtained with ultra-high Q superconducting radiofrequency (SRF) cavities. This new surface encapsulation strategy enables further reduction of dielectric losses via passivation with ambient-stable materials, while preserving fabrication and scalable manufacturability thanks to the compatibility with silicon processes

    Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical study

    Get PDF
    Background: The clinical outcome of hip resurfacing (HR) as a demanding surgical technique associated with a substantial learning curve depends on the position of the femoral component. The aim of the study was to investigate the effects of the level of surgical experience on computer-assisted imageless navigation concerning precision of femoral component positioning, notching, and oversizing rate, as well as operative time. Methods: Three surgeons with different levels of experience in both HR and computer-assisted surgery (CAS) prepared the femoral heads of 54 synthetic femurs using the Durom TM Hip Resurfacing (Zimmer, Warsaw, IN, USA) system. Each surgeon prepared a total of 18 proximal femurs using the NavitrackÂź system (ORTHOsoft Inc., Montreal, Canada) or the conventional free-hand Durom TM K-wire positioning jig. The differences between planned and postoperative stem shaft angle (SSA) and anteversion angle in standardized x-rays were measured and the operative time, not including the time for calibrating the CAS-system, was documented. Notching was evaluated by the three surgeons in a randomized manner. Oversizing was determined by the difference of the preoperative determined cap and the cap size advised by the CAS-system. Results: CAS significantly reduced the overall mean deviation between planned and postoperative SSA in comparison with the conventional procedure (mean ± SD, 1 ± 1.7° vs. 7.4 ± 4.4°, P <0.01) regardless of the surgeon’s level of experience. The incidence of either varus or valgus SSA deviations exceeding 5° were 1/27 for CAS and 15/27 for the conventional method, respectively (P<0.001), corresponding to a reduction by 97%. Using CAS, the rate of notching was reduced by 100%. Conclusions: The accuracy of femoral HR component orientation is significantly increased by use of CAS regardless of the surgeon’s level of experience in our preclinical study. Thus, imageless computer-assisted navigation can be a valuable tool to improve implant positioning in HR for surgeons at any stage of their learning curve

    Acetabular- and femoral orientation after periacetabular osteotomy as a predictor for outcome and osteoarthritis

    No full text
    Background!#!Periacetabular osteotomy is a successful treatment for hip dysplasia. The results are influenced, however, by optimal positioning of the acetabular fragment, femoral head morphology and maybe even femoral version as well as combined anteversion have an impact. In order to obtain better insight on fragment placement, postoperative acetabular orientation and femoral morphology were evaluated in a midterm follow-up in regard to functional outcome and osteoarthritis progression.!##!Methods!#!A follow-up examination with 49 prospectively documented patients (66 hips) after periacetabular osteotomy (PAO) was performed after 62.2 ± 18.6 months. Mean age of patients undergoing surgery was 26.7 ± 9.6 years, 40 (82%) of these patients were female. All patients were evaluated with an a.p. pelvic x-ray and an isotropic MRI in order to assess acetabular version, femoral head cover, alpha angle, femoral torsion and combined anteversion. The acetabular version was measured at the femoral head center as well as 0.5 cm below and 0.5 and 1 cm above the femoral head center and in addition seven modified acetabular sector angles were determined. Femoral torsion was assessed in an oblique view of the femoral neck. The combined acetabular and femoral version was calculated as well. To evaluate the clinical outcome the pre- and postoperative WOMAC score as well as postoperative Oxford Hip Score and Global Treatment Outcome were analyzed.!##!Results!#!After PAO acetabular version at the femoral head center (31.4 ± 9.6°) was increased, the anterior cover at the 15 o'clock position (34.7 ± 15.4°) was reduced and both correlated significantly with progression of osteoarthritis, although not with the functional outcome. Combined acetabular and femoral torsion had no influence on the progression of osteoarthritis or outcome scores.!##!Conclusion!#!Long-term results after PAO are dependent on good positioning of the acetabular fragment in all 3 planes. Next to a good lateral coverage a balanced horizontal alignment without iatrogenic pincer impingement due to acetabular retroversion, or insufficient coverage of the anterior femoral head is important

    MRI-based static and functional assessment of complex hip deformities in comparison with CT: a validation study

    No full text
    Objective!#!This study aimed at investigating the agreement between predefined quantitative parameters of hip morphology derived from magnetic resonance imaging (MRI) and virtual range of motion (ROM) analysis using computed tomography (CT) as standard of reference.!##!Methods!#!Twenty patients (13 females, 7 males, 16-59 years) with hip deformities underwent MRI prior to surgery. Clockwise alpha angle, femoral head and neck diameter, collum caput diaphysis angle, femoral torsion, center-edge angles, acetabular coverage of the femoral head, sourcil angle, and acetabular anteversion were measured. Additionally, tern single and combined movements were simulated using a motion analysis program. The MRI findings were compared with the corresponding results obtained by CT. Correlation of MRI with CT was assessed using different statistical methods (intraclass correlation coefficient, Bland-Altmann plot, two one-sided t test), and linear regression analysis was performed.!##!Results!#!The results showed near-perfect intraclass correlation coefficients (ICCs) for anteversion (0.95), acetabular sector angles (0.98-0.99), sourcil angle (0.95), and acetabular coverage (anterior 0.96, posterior 0.99). Intermethod correlation for femoral parameters showed almost perfect agreement except for the alpha angle (0.73-0.97). No significant proportional bias was detected for traditional acetabular and femoral parameters. ROM analysis was performed for 370 movements in 37 hips. For 78.4% (290/370) of the movements analysed, neither CT nor MRI detected impingement across the physiological ROM. For 18.6% (69/370) of the movements, impingement was detected by both CT and MRI, while 2.2% (8/370) of the movements with impingement in CT showed no impingement in MRI, and 0.8% (3/370) of the movements with impingement in MRI had no corresponding result in CT.!##!Conclusion!#!Finally, it was concluded that MRI-based assessment of hip morphology and virtual ROM analysis is feasible and can be performed with good intermethod agreement in comparison to the gold standard (CT). Therefore, MRI appears to be substantially equivalent to CT for use in virtual ROM analysis and so may reasonably be used in place of CT for this purpose

    Ultrasonic bone cement removal efficiency in total joint arthroplasty revision: A computer tomographic‐based cadaver study

    No full text
    Polymethylmethacrylate (PMMA) removal during septic total joint arthroplasty revision is associated with a high fracture and perforation risk. Ultrasonic cement removal is considered a bone-preserving technique. Currently, there is still a lack of sound data on efficacy as it is difficult to detect smaller residues with reasonable technical effort. However, incomplete removal is associated with the risk of biofilm coverage of the residue. Therefore, the study aimed to investigate the efficiency of ultrasonic-based PMMA removal in a human cadaver model. The femoral components of a total hip and a total knee prosthesis were implanted in two cadaver femoral canals by 3rd generation cement fixation technique. Implants were then removed. Cement mantle extraction was performed with the OSCAR-3-System ultrasonic system (OrthofixÂź). Quantitative analysis of cement residues was carried out with dual-energy and microcomputer tomography. With a 20 ”m resolution, in vitro microcomputer tomography visualized tiniest PMMA residues. For clinical use, dual-energy computer tomography tissue decomposition with 0.75 mm resolution is suitable. With ultrasound, more than 99% of PMMA was removed. Seven hundred thirty-four residues with a mean volume of 0.40 ± 4.95 mm3 were identified with only 4 exceeding 1 cm in length in at least one axis. Ultrasonic cement removal of PMMA was almost complete and can therefore be considered a highly effective technique. For the first time, PMMA residues in the sub-millimetre range were detected by computer tomography. Clinical implications of the small remaining PMMA fraction on the eradication rate of periprosthetic joint infection warrants further investigations
    corecore