    Near Elimination of Ventricular Pacing in SafeR Mode Compared to DDD Modes: A Randomized Study of 422 Patients

    Get PDF
    Aims:SafeR performance versus DDD/automatic mode conversion (DDD/AMC) and DDD with a 250-ms atrioventricular (AV) delay (DDD/LD) modes was assessed toward ventricular pacing (Vp) reduction. Methods:After a 1-month run-in phase, recipients of dual-chamber pacemakers without persistent AV block and persistent atrial fibrillation (AF) were randomly assigned to SafeR, DDD/AMC, or DDD/LD in a 1:1:1 design. The main endpoint was the percentage of Vp (%Vp) at 2 months and 1 year after randomization, ascertained from device memories. Secondary endpoints include %Vp at 1 year according to pacing indication and 1-year AF incidence based on automatic mode switch device stored episodes. Results:Among 422 randomized patients (73.2 ± 10.6 years, 50% men, sinus node dysfunction 47.4%, paroxysmal AV block 30.3%, bradycardia-tachycardia syndrome 21.8%), 141 were assigned to SafeR versus 146 to DDD/AMC and 135 to DDD/LD modes. Mean %Vp at 2 months was 3.4 ± 12.6% in SafeR versus 33.6 ± 34.7% and 14.0 ± 26.0% in DDD/AMC and DDD/LD modes, respectively (P < 0.0001 for both). At 1 year, mean %Vp in SafeR was 4.5 ± 15.3% versus 37.9 ± 34.4% and 16.7 ± 28.0% in DDD/AMC and DDD/LD modes, respectively (P < 0.0001 for both). The proportion of patients in whom Vp was completely eliminated was significantly higher in SafeR (69%) versus DDD/AMC (15%) and DDD/LD (45%) modes (P < 0.0001 for both), regardless of pacing indication. The absolute risk of developing permanent AF or of remaining in AF for >30% of the time was 5.4% lower in SafeR than in the DDD pacing group (ns). Conclusions:In this selected patient population, SafeR markedly suppressed unnecessary Vp compared with DDD modes. PACE 2012; 35:392–402

    Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study

    Get PDF
    Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.Peer reviewe

    Atrial fibrillation in recipients of cardiac resynchronization therapy device: 1-year results of the randomized MASCOT trial

    No full text
    Background: Atrial fibrillation (AF) is associated with increased morbidity and mortality in patients suffering from heart failure (HF). Patients in New York Heart Association HF classes III or IV, with systolic dysfunction and a wide QRS, are candidates for cardiac resynchronization therapy (CRT), and might benefit from atrial overdrive pacing (AOP). Methods: The Management of Atrial fibrillation Suppression in AF-HF COmorbidity Therapy (MASCOT) trial enrolled 409 CRT device recipients (79% men), who were randomly assigned to AOP ON (n = 197), versus AOP OFF (n = 197) and followed up for 1 year. Their mean age was 68 ± 10 years, left ventricular ejection fraction 25 ± 6%, QRS duration 163 ± 29 milliseconds. New York Heart Association class III was present in 86% of patients and 19% had a history of paroxysmal AF. The primary study end point was incidence of permanent AF at 1 year. Results: Atrial overdrive pacing increased the percentage of atrial pacing from 30% to 80% (P < .0001), was well tolerated, and did not interfere with (a) delivery of CRT (95% mean ventricular pacing in both groups), (b) response to CRT (70% responders in the control vs 67% in the treatment group), or (c) cardiac function (left ventricular ejection fraction increased from 24.5% ± 6.2% to 32.7% ± 10.9% in the control and from 25.8% ± 6.8% to 33.1% ± 12.6% in the treatment group). The incidence of permanent AF was 3.3% in both groups. By logistic regression analysis, a history of AF (P < .001) and absence of antiarrhythmic drugs (P = .002) were associated with permanent AF. Conclusions: In this first trial of a specific AF prevention algorithm in CRT recipients, AOP was safe and did not worsen HF. The prevention algorithm did not lower the 1-year incidence of AF. © 2008 Mosby, Inc. All rights reserved

    Directed assembly of living Pseudomonas aeruginosa on PEI patterns fabricated by nanoxerography for statistical AFM bio-experiments

    No full text
    International audienceImmobilization of living micro-organisms on predefined areas of substrates is a prerequisite for their characterizations by atomic force microscopy (AFM) in culture media. It remains challenging since micro-organisms should not be denatured but attached strongly enough to be scanned with an AFM tip, in a liquid phase. In this work, a novel approach is proposed to electrostatically assemble biological objects of interest on 2 nm thick polyethylenimine (PEI) patterns fabricated by nanoxerography. This nanoxerography process involves electrostatic trapping of PEI chains on negatively charged patterns written on electret thin films by AFM or electrical microcontact printing. The capability of this approach is demonstrated using a common biological system, Pseudomonas aeruginosa bacteria. These negatively charged bacteria are selectively assembled on large scale arrays of PEI patterns. In contrast to other PEI continuous films commonly used for cell anchoring, these ultrathin PEI patterns strongly attached on the surface do not cause any denaturation of the assembled Pseudomonas aeruginosa bacteria. AFM characterizations of large populations of individual living bacteria in culture media can thus be easily performed through this approach, providing the opportunity to perform representative statistical data analysis. Interestingly, this process may be extended to any negatively charged micro-organism in solution

    Use of atomic force microscopy (AFM) to explore cell wall properties and response to stress in the yeast Saccharomyces cerevisiae

    No full text
    Over the past 20 years, the yeast cell wall has been thoroughly investigated by genetic and biochemical methods, leading to remarkable advances in the understanding of its biogenesis and molecular architecture as well as to the mechanisms by which this organelle is remodeled in response to environmental stresses. Being a dynamic structure that constitutes the frontier between the cell interior and its immediate surroundings, imaging cell surface, measuring mechanical properties of cell wall or probing cell surface proteins for localization or interaction with external biomolecules are among the most burning questions that biologists wished to address in order to better understand the structure-function relationships of yeast cell wall in adhesion, flocculation, aggregation, biofilm formation, interaction with antifungal drugs or toxins, as well as response to environmental stresses, such as temperature changes, osmotic pressure, shearing stress, etc. The atomic force microscopy (AFM) is nowadays the most qualified and developed technique that offers the possibilities to address these questions since it allows working directly on living cells to explore and manipulate cell surface properties at nanometer resolution and to analyze cell wall proteins at the single molecule level. In this minireview, we will summarize the most recent contributions made by AFM in the analysis of the biomechanical and biochemical properties of the yeast cell wall and illustrate the power of this tool to unravel unexpected effects caused by environmental stresses and antifungal agents on the surface of living yeast cells