Development of a novel diffuse correlation spectroscopy platform for monitoring cerebral blood flow and oxygen metabolism: from novel concepts and devices to preclinical live animal studies
New optical technologies were developed to continuously measure cerebral blood flow (CBF) and oxygen metabolism (CMRO2) non-invasively through the skull. Methods and devices were created to improve the performance of near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) for use in experimental animals and humans. These were employed to investigate cerebral metabolism and cerebrovascular reactivity under different states of anesthesia and during models of pathological states.
Burst suppression is a brain state arising naturally in pathological conditions or under deep general anesthesia, but its mechanism and consequences are not well understood. Electroencephalography (EEG) and cortical hemodynamics were simultaneously measured in rats to evaluate the coupling between cerebral oxygen metabolism and neuronal activity in the burst suppressed state. EEG bursts were used to deconvolve NIRS and DCS signals into the hemodynamic and metabolic response function for an individual burst. This response was found to be similar to the stereotypical functional hyperemia evoked by normal brain activation. Thus, spontaneous burst activity does not cause metabolic or hemodynamic dysfunction in the cortex. Furthermore, cortical metabolic activity was not associated with the initiation or termination of a burst.
A novel technique, time-domain DCS (TD-DCS), was introduced to significantly increase the sensitivity of transcranial CBF measurements to the brain. A new time-correlated single photon counting (TCSPC) instrument with a custom high coherence pulsed laser source was engineered for the first-ever simultaneous measurement of photon time of flight and DCS autocorrelation decays. In this new approach, photon time tags are exploited to determine path-length-dependent autocorrelation functions. By correlating photons according to time of flight, CBF is distinguished from superficial blood flow. Experiments in phantoms and animals demonstrate TD-DCS has significantly greater sensitivity to the brain than existing transcranial techniques.
Intracranial pressure (ICP) modulates both steady-state and pulsatile CBF, making CBF a potential marker for ICP. In particular, the critical closing pressure (CrCP) has been proposed as a surrogate measure of ICP. A new DCS device was developed to measure pulsatile CBF non-invasively. A novel method for estimating CrCP and ICP from DCS measurement of pulsatile microvascular blood flow in the cerebral cortex was demonstrated in rats.2018-03-08T00:00:00
Monomer–dimer dynamics and distribution of GPI-anchored uPAR are determined by cell surface protein assemblies
To search for functional links between glycosylphosphatidylinositol (GPI) protein monomer–oligomer exchange and membrane dynamics and confinement, we studied urokinase plasminogen activator (uPA) receptor (uPAR), a GPI receptor involved in the regulation of cell adhesion, migration, and proliferation. Using a functionally active fluorescent protein–uPAR in live cells, we analyzed the effect that extracellular matrix proteins and uPAR ligands have on uPAR dynamics and dimerization at the cell membrane. Vitronectin directs the recruitment of dimers and slows down the diffusion of the receptors at the basal membrane. The commitment to uPA–plasminogen activator inhibitor type 1–mediated endocytosis and recycling modifies uPAR diffusion and induces an exchange between uPAR monomers and dimers. This exchange is fully reversible. The data demonstrate that cell surface protein assemblies are important in regulating the dynamics and localization of uPAR at the cell membrane and the exchange of monomers and dimers. These results also provide a strong rationale for dynamic studies of GPI-anchored molecules in live cells at steady state and in the absence of cross-linker/clustering agents
Time-domain diffuse correlation spectroscopy
Physiological monitoring of oxygen delivery to the brain has great significance for improving the management of patients at risk for brain injury. Diffuse correlation spectroscopy (DCS) is a rapidly growing optical technology able to non-invasively assess the blood flow index (BFi) at the bedside. The current limitations of DCS are the contamination introduced by extracerebral tissue and the need to know the tissue's optical properties to correctly quantify the BFi. To overcome these limitations, we have developed a new technology for time-resolved diffuse correlation spectroscopy. By operating DCS in the time domain (TD-DCS), we are able to simultaneously acquire the temporal point-spread function to quantify tissue optical properties and the autocorrelation function to quantify the BFi. More importantly, by applying time-gated strategies to the DCS autocorrelation functions, we are able to differentiate between short and long photon paths through the tissue and determine the BFi for different depths. Here, we present the novel device and we report the first experiments in tissue-like phantoms and in rodents. The TD-DCS method opens many possibilities for improved non-invasive monitoring of oxygen delivery in humans
Capillary electrophoresis of ultrasmall carboxylate functionalized silicon nanoparticles
Capillary electrophoresis is used to separate ultrasmall ( approximately 1 nm) carboxylate functionalized Si nanoparticles (Si-np-COO(-)) prepared via hydrosilylation with an omega-ester 1-alkene. The electropherograms show a monodisperse Si core size with one or two carboxylate groups added to the surface. On-column detection of their laser-induced fluorescence demonstrates that the individual Si-np-COO(-) have narrow emissions (full width at half maximum = 30-40 nm) with a nearly symmetric lineshape. Preparative scale electrophoresis should be a viable route for purification of the Si-np-COO(-) for further study and future applications
Erratum: Prolonged monitoring of cerebral blood flow and autoregulation with diffuse correlation spectroscopy in neurocritical care patients
Corrected disclosures for the article “Prolonged monitoring of cerebral blood flow and autoregulation with diffuse correlation spectroscopy in neurocritical care patients.” DOI: 10.1117/1.NPh.5.4.045005.Published versio
BMI, Weight Discrimination, and Psychological, Behavioral, and Interpersonal Responses to the Coronavirus Pandemic.
ObjectiveThis study aimed to examine whether BMI and weight discrimination are associated with psychological, behavioral, and interpersonal responses to the coronavirus pandemic.MethodsUsing a prospective design, participants (N = 2,094) were first assessed in early February 2020 before the coronavirus crisis in the United States and again in mid-March 2020 during the President's "15 Days to Slow the Spread" guidelines. Weight, height, and weight discrimination were assessed in the February survey. Psychological, behavioral, and interpersonal responses to the coronavirus were assessed in the March survey.ResultsPrepandemic experiences with weight discrimination were associated with greater concerns about the virus, engaging in more preventive behaviors, less trust in people and institutions to manage the outbreak, and greater perceived declines in connection to one's community. BMI tended to be unrelated to these responses.ConclusionsDespite the risks of complications of coronavirus disease associated with obesity, individuals with higher BMI were neither more concerned about the virus nor taking more behavioral precautions than individuals in other weight categories. Weight discrimination, in contrast, may heighten vigilance to threat, which may have contributed to both positive (greater concern, more precautionary behavior) and negative (less trust, declines community connection) responses to the pandemic
Serial two-photon tomography for automated ex vivo mouse brain imaging
Here we describe an automated method, named serial two-photon (STP) tomography, that achieves high-throughput fluorescence imaging of mouse brains by integrating two-photon microscopy and tissue sectioning. STP tomography generates high-resolution datasets that are free of distortions and can be readily warped in three dimensions, for example, for comparing multiple anatomical tracings. This method opens the door to routine systematic studies of neuroanatomy in mouse models of human brain disorders