648 research outputs found

    Inhibition of transforming growth factor-β restores endothelial thromboresistance in vein grafts

    Get PDF
    BackgroundThrombosis is a major cause of the early failure of vein grafts (VGs) implanted during peripheral and coronary arterial bypass surgeries. Endothelial expression of thrombomodulin (TM), a key constituent of the protein C anticoagulant pathway, is markedly suppressed in VGs after implantation and contributes to local thrombus formation. While stretch-induced paracrine release of transforming growth factor-β (TGF-β) is known to negatively regulate TM expression in heart tissue, its role in regulating TM expression in VGs remains unknown.MethodsChanges in relative mRNA expression of major TGF-β isoforms were measured by quantitative polymerase chain reaction (qPCR) in cultured human saphenous vein smooth muscle cells (HSVSMCs) subjected to cyclic stretch. To determine the effects of paracrine release of TGF-β on endothelial TM mRNA expression, human saphenous vein endothelial cells (HSVECs) were co-cultured with stretched HSVSMCs in the presence of 1D11, a pan-neutralizing TGF-β antibody, or 13C4, an isotype-control antibody. Groups of rabbits were then administered 1D11 or 13C4 and underwent interpositional grafting of jugular vein segments into the carotid circulation. The effect of TGF-β inhibition on TM gene expression was measured by qPCR; protein C activating capacity and local thrombus formation were measured by in situ chromogenic substrate assays; and VG remodeling was assessed by digital morphometry.ResultsCyclic stretch induced TGF-β1 expression in HSVSMCs by 1.9 ± 0.2-fold (P < .001) without significant change in the expressions of TGF-β2 and TGF-β3. Paracrine release of TGF-β1 by stretched HSVSMCs inhibited TM expression in stationary HSVECs placed in co-culture by 57 ± 12% (P = .03), an effect that was abolished in the presence of 1D11. Similarly, TGF-β1 was the predominant isoform induced in rabbit VGs 7 days after implantation (3.5 ± 0.4-fold induction; P < .001). TGF-β1 protein expression localized predominantly to the developing neointima and coincided with marked suppression of endothelial TM expression (16% ± 2% of vein controls; P < .03), a reduction in situ activated protein C (APC)-generating capacity (53% ± 9% of vein controls; P = .001) and increased local thrombus formation (3.7 ± 0.8-fold increase over vein controls; P < .01). External stenting of VGs to limit vessel distension significantly reduced TGF-β1 induction and TM downregulation. Systemic administration of 1D11 also effectively prevented TM downregulation, preserved APC-generating capacity, and reduced local thrombus in rabbit VGs without observable effect on neointima formation and other morphometric parameters 6 weeks after implantation.ConclusionTM downregulation in VGs is mediated by paracrine release of TGF-β1 caused by pressure-induced vessel stretch. Systemic administration of an anti-TGF-β antibody effectively prevented TM downregulation and preserved local thromboresistance without negative effect on VG remodeling.Clinical RelevanceVein grafts (VGs) are commonly used conduits for coronary and peripheral arterial bypass surgeries. Thrombosis is a major cause of early VG failure. Trombomodulin (TM), a key component of the anticoagulant protein C pathway, is downregulated early after VG implantation and facilitates local thrombus formation. We found that paracrine release of transforming growth factor-β1 (TGF-β1), caused by pressure-induced stretch, was a potent negative regulator of TM in rabbit VGs. Administration of a neutralizing anti-TGF-β antibody effectively prevented TM downregulation and reduced local thrombus generation without adversely affecting long-term VG remodeling. This may represent a novel strategy to improve patency in patients undergoing arterial bypass procedures

    Techno-economic analysis of decentralized biomass processing depots

    Get PDF
    AbstractDecentralized biomass processing facilities, known as biomass depots, may be necessary to achieve feedstock cost, quantity, and quality required to grow the future U.S. bioeconomy. In this paper, we assess three distinct depot configurations for technical difference and economic performance. The depot designs were chosen to compare and contrast a suite of capabilities that a depot could perform ranging from conventional pelleting to sophisticated pretreatment technologies. Our economic analyses indicate that depot processing costs are likely to range from ∼US30toUS30 to US63 per dry metric tonne (Mg), depending upon the specific technology implemented and the energy consumption for processing equipment such as grinders and dryers. We conclude that the benefits of integrating depots into the overall biomass feedstock supply chain will outweigh depot processing costs and that incorporation of this technology should be aggressively pursued

    Noncovalent Functionalization of Graphene and Graphene Oxide for Energy Materials, Biosensing, Catalytic, and Biomedical Applications

    Get PDF
    This Review focuses on noncovalent functionalization of graphene and graphene oxide with various species involving biomolecules, polymers, drugs, metals and metal oxide-based nanoparticles, quantum dots, magnetic nanostructures, other carbon allotropes (fullerenes, nanodiamonds, and carbon nanotubes), and graphene analogues (MoS2, WS2). A brief description of pi-pi interactions, van der Waals forces, ionic interactions, and hydrogen bonding allowing noncovalent modification of graphene and graphene oxide is first given. The main part of this Review is devoted, to tailored functionalization for applications in drug delivery, energy materials, solar cells, water splitting, biosensing, bioimaging, environmental, catalytic, photocatalytic, and biomedical technologies. A significant part of this Review explores the possibilities of graphene/graphene oxide-based 3D superstructures and their use in lithium-ion batteries. This Review ends with a look at challenges and future prospects of noncovalently modified graphene and graphene oxideope

    The Accuracy of the Electrocardiogram during Exercise Stress Test Based on Heart Size

    Get PDF
    BACKGROUND: Multiple studies have shown that the exercise electrocardiogram (ECG) is less accurate for predicting ischemia, especially in women, and there is additional evidence to suggest that heart size may affect its diagnostic accuracy. HYPOTHESIS: The purpose of this investigation was to assess the diagnostic accuracy of the exercise ECG based on heart size. METHODS: We evaluated 1,011 consecutive patients who were referred for an exercise nuclear stress test. Patients were divided into two groups: small heart size defined as left ventricular end diastolic volume (LVEDV) <65 mL (Group A) and normal heart size defined as LVEDV ≥65 mL (Group B) and associations between ECG outcome (false positive vs. no false positive) and heart size (small vs. normal) were analyzed using the Chi square test for independence, with a Yates continuity correction. LVEDV calculations were performed via a computer-processing algorithm. SPECT myocardial perfusion imaging was used as the gold standard for the presence of coronary artery disease (CAD). RESULTS: Small heart size was found in 142 patients, 123 female and 19 male patients. There was a significant association between ECG outcome and heart size (χ(2) = 4.7, p = 0.03), where smaller hearts were associated with a significantly greater number of false positives. CONCLUSIONS: This study suggests a possible explanation for the poor diagnostic accuracy of exercise stress testing, especially in women, as the overwhelming majority of patients with small heart size were women

    Predicting GP visits: A multinomial logistic regression investigating GP visits amongst a cohort of UK patients living with Myalgic encephalomyelitis

    Get PDF
    Background Myalgic Encephalomyelitis (ME) is a chronic condition whose status within medicine is the subject of on-going debate. Some medical professionals regard it as a contentious illness. Others report a lack of confidence with diagnosis and management of the condition. The genesis of this paper was a complaint, made by an ME patient, about their treatment by a general practitioner. In response to the complaint, Healthwatch Trafford ran a patient experience-gathering project. Method Data was collected from 476 participants (411 women and 65 men), living with ME from across the UK. Multinomial logistic regression investigated the predictive utility of length of time with ME; geographic location (i.e. Manchester vs. rest of UK); trust in GP; whether the patient had received a formal diagnosis; time taken to diagnosis; and gender. The outcome variable was number of GP visits per year. Results All variables, with the exception of whether the patient had received a formal diagnosis, were significant predictors. Conclusions Relationships between ME patients and their GPs are discussed and argued to be key to the effective delivery of care to this patient cohort. Identifying potential barriers to doctor patient interactions in the context of ME is crucial

    In Vivo Comparison of Two Human Norovirus Surrogates for Testing Ethanol-Based Handrubs: The Mouse Chasing the Cat!

    Get PDF
    Human noroviruses (HuNoV), a major cause of acute gastroenteritis worldwide, cannot be readily cultured in the lab. Therefore, a feline calicivirus (FCV) is often used as its surrogate to, among other things, test alcohol-based handrubs (ABHR). The more recent laboratory culture of a mouse norovirus (MNV) provides an alternative. While MNV is closer to HuNoV in several respects, to date, no comparative testing of FCV and MNV survival and inactivation on human hands has been performed. This study was designed to address the knowledge gap. The rates of loss in viability during drying on hands were −1.91 and −1.65% per minute for FCV and MNV, respectively. When the contaminated skin was exposed for 20 s to either a commercial ABHR with 62% (v/v) ethanol or to 75% (v/v) ethanol in water, FCV infectivity was reduced by <1 log10 while that of MNV by nearly 2.8 log10. Extending the contact time to 30 s reduced the FCV titer by almost 2 log10 by both test substances and that of MNV by >3.5 log10 by the commercial ABHR while 75% ethanol did not show any noticeable improvement in activity as compared to the 20 s contact. An 80% (v/v) aqueous solution of ethanol gave only a 1.75 log10 reduction in MNV activity after 20 s. The results show significant differences in the ethanol susceptibility of FCV and MNV in contact times relevant to field use of ABHR and also that 62% ethanol was a more effective virucide than either 75% or 80% ethanol. These findings indicate the need for a review of the continuing use of FCV as a surrogate for HuNoV
    corecore