8 research outputs found

    The endogenous thrombin potential in patients with left ventricular assist device or heart transplant

    Get PDF
    BackgroundThe Heartmate 3 (HM 3) is a left ventricular assist device featuring less shear stress, milder acquired von Willebrand syndrome, and fewer bleeding incidences than its predecessor the Heartmate II (HM II). The novel surface coating of the HM 3 suggests less contact activation of plasmatic coagulation. We hypothesized that patients with HM 3 exhibit fewer aberrations in their thrombin potential than patients with HM II. We compared these results with the thrombin potential of patients with heart transplantation (HTX).MethodsThrombin generation in plasma samples of patients with HM II (n = 16), HM 3 (n = 20), and HTX (n = 13) was analyzed 3 days after implantation/transplantation and after long-term support (3–24 months) with HM II (n = 16) or HM 3 (n = 12) using calibrated automated thrombography. Heparin in postoperative samples was antagonized with polybrene.ResultsThree days postoperatively HM II patients exhibited a lower endogenous thrombin potential (ETP) than HM 3 and HTX patients (HM II: 947 ± 291 nM*min; HM 3: 1231 ± 176 nM*min; HTX: 1376 ± 162 nM*min, p < 0.001) and a lower velocity index of thrombin generation (HM II: 18.74 ± 10.90 nM/min; HM 3: 32.41 ± 9.51 nM/min; HTX: 37.65 ± 9.41 nM/min, p < 0.01). Subtle differences in the thrombin generation profiles remained in HM II and HM 3 patients under long-term support (Velocity Index: HM II: 38.70 ± 28.46 nM/min; HM 3: 73.32 ± 32.83 nM/min, p < 0.05). Prothrombin fragments 1 + 2 were higher in HM II than in HM 3 patients (HM II: 377.7 ± 208.4 pM; HM 3: 202.1 ± 87.7 pM, p < 0.05) and correlated inversely with the ETP (r = −0.584, p < 0.05).ConclusionWe observed a more aberrant thrombin generation in HM II than in HM 3 despite comparable anticoagulation and routine parameters. A trend toward lower values was still observable in HM 3 compared to HTX patients. Calibrated automated thrombography may be a good tool to monitor the coagulation state of these patients and guide anticoagulation in the future

    Experimental validation of granular flow kinetic theory under turbulent flow conditions

    No full text
    The mixed classical and extended kinetic theory of granular ows is used for modeling the characteristics of particles-water turbulent sheet ow. The open-source solver sedFoam v3.1 is used for the 1-D and 2-D ow simulations. The simulation results are compared to the experimental data measured in the open channel. After that, the simulation parameters are optimized to achieve the best possible agreement between the simulation and the experimental results. The unsatisfactory performance of the KT models and the observed simulation instabilities are discussed

    Cardiopulmonary resuscitation (CPR) during spaceflight - a guideline for CPR in microgravity from the German Society of Aerospace Medicine (DGLRM) and the European Society of Aerospace Medicine Space Medicine Group (ESAM-SMG).

    No full text
    BACKGROUND With the "Artemis"-mission mankind will return to the Moon by 2024. Prolonged periods in space will not only present physical and psychological challenges to the astronauts, but also pose risks concerning the medical treatment capabilities of the crew. So far, no guideline exists for the treatment of severe medical emergencies in microgravity. We, as a international group of researchers related to the field of aerospace medicine and critical care, took on the challenge and developed a an evidence-based guideline for the arguably most severe medical emergency - cardiac arrest. METHODS After the creation of said international group, PICO questions regarding the topic cardiopulmonary resuscitation in microgravity were developed to guide the systematic literature research. Afterwards a precise search strategy was compiled which was then applied to "MEDLINE". Four thousand one hundred sixty-five findings were retrieved and consecutively screened by at least 2 reviewers. This led to 88 original publications that were acquired in full-text version and then critically appraised using the GRADE methodology. Those studies formed to basis for the guideline recommendations that were designed by at least 2 experts on the given field. Afterwards those recommendations were subject to a consensus finding process according to the DELPHI-methodology. RESULTS We recommend a differentiated approach to CPR in microgravity with a division into basic life support (BLS) and advanced life support (ALS) similar to the Earth-based guidelines. In immediate BLS, the chest compression method of choice is the Evetts-Russomano method (ER), whereas in an ALS scenario, with the patient being restrained on the Crew Medical Restraint System, the handstand method (HS) should be applied. Airway management should only be performed if at least two rescuers are present and the patient has been restrained. A supraglottic airway device should be used for airway management where crew members untrained in tracheal intubation (TI) are involved. DISCUSSION CPR in microgravity is feasible and should be applied according to the Earth-based guidelines of the AHA/ERC in relation to fundamental statements, like urgent recognition and action, focus on high-quality chest compressions, compression depth and compression-ventilation ratio. However, the special circumstances presented by microgravity and spaceflight must be considered concerning central points such as rescuer position and methods for the performance of chest compressions, airway management and defibrillation
    corecore