322 research outputs found

    Test in a beam of large-area Micromegas chambers for sampling calorimetry

    Full text link
    Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1×\times1 m2^{2} were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility

    B3 : trop ou pas assez de chirurgie ?

    Get PDF

    Influence of clinical and gait analysis experience on reliability of observational gait analysis (Edinburgh Gait Score Reliability)

    Get PDF
    AbstractObjectivesTreatment complexity of cerebral palsy (CP) patients imposes outcome evaluation studies, which may include objective technical analysis and more subjective functional evaluation. The Edinburgh Gait Score (EGS) was proposed as an additive or alternative when complex instrumented three-dimensional gait analysis is not available. Our purposes were to apply a translated EGS to standard video recordings of independent walking spastic diplegic CP patients, to evaluate its intraobserver and interobserver reliability with respect to gait analysis familiar and not familiar observers.MethodsTen standard video recordings acquired during routine clinical gait analysis were examined by eight observers gait analysis interpretation experienced or not, out of various specialities, two times with a two weeks interval. Kappa statistics and intraclass correlation coefficient were calculated.ResultsBetter reliability was observed for foot and knee scores than in proximal segments with significant differences between stance and swing phase. Significantly better results in gait analysis trained observers underlines the importance to either be used to clinical gait analysis interpretation, or to benefit of video analysis training before observational scoring.ConclusionVisual evaluation may be used for outcome studies to explore clinical changes in CP patients over time and may be associated to other validated evaluation tools

    Resistive micromegas for sampling calorimetry

    Get PDF
    MicromegasInternational audienceMicromegas is an attractive option for a gaseous sampling calorimeter. It delivers proportional and fast signals, achieves high efficiency to minimum ionising particles with a compact design and shows well-uniform performance over meter-square areas. The current R&D focuses on large- size spark-protected Micromegas with integrated front-end electronics. It targets an application at future linear colliders (LC) and possible upgrades of LHC experiments for the running at high luminosity. In the later case, occasional sparking should be suppressed to avoid dead-time and technical solutions using resistive coatings are investigated. Small prototypes of resistive and non-resistive Micromegas were constructed and tested in a beam at DESY. Results are reported with emphasis on the impact of the resistive layer on the detector performance

    Breast tumors: an overview

    Get PDF
    Review on Breast tumors: an overview, with data on clinics, and the genes involved

    MICROMEGAS chambers for hadronic calorimetry at a future linear collider

    Full text link
    Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented
    • …
    corecore