2,860 research outputs found

    Sialylation of campylobacter jejuni lipo-oligosaccharides: impact on phagocytosis and cytokine production in mice

    Get PDF
    <p>Background: Guillain-Barré syndrome (GBS) is a post-infectious polyradiculoneuropathy, frequently associated with antecedent Campylobacter jejuni (C. jejuni) infection. The presence of sialic acid on C. jejuni lipo-oligosaccharide (LOS) is considered a risk factor for development of GBS as it crucially determines the structural homology between LOS and gangliosides, explaining the induction of cross-reactive neurotoxic antibodies. Sialylated C. jejuni are recognised by TLR4 and sialoadhesin; however, the functional implications of these interactions in vivo are unknown.</p> <p>Methodology/Principal Findings: In this study we investigated the effects of bacterial sialylation on phagocytosis and cytokine secretion by mouse myeloid cells in vitro and in vivo. Using fluorescently labelled GM1a/GD1a ganglioside-mimicking C. jejuni strains and corresponding (Cst-II-mutant) control strains lacking sialic acid, we show that sialylated C. jejuni was more efficiently phagocytosed in vitro by BM-MΦ, but not by BM-DC. In addition, LOS sialylation increased the production of IL-10, IL-6 and IFN-β by both BM-MΦ and BM-DC. Subsequent in vivo experiments revealed that sialylation augmented the deposition of fluorescent bacteria in splenic DC, but not macrophages. In addition, sialylation significantly amplified the production of type I interferons, which was independent of pDC.</p> <p>Conclusions/Significance: These results identify novel immune stimulatory effects of C. jejuni sialylation, which may be important in inducing cross-reactive humoral responses that cause GBS</p&gt

    Influence of Anaesthesia on Mobilisation Following Hip Fracture Surgery : An Observational Study: 麻醉技術對髖部骨折病人術後活動能力的影響:一項觀察性研究

    Get PDF
    Background Anaesthetic technique can influence mortality and morbidity following hip fracture surgery. However, its influence on postoperative mobilisation is not clear. In this study, we evaluated the influence of anaesthetic technique on postoperative mobilisation. Methods In this prospective observational study, we included all consecutive patients who underwent surgery for hip fracture between 1 January 2012 and 31 December 2013 at our institution. Any patients who died prior to mobilisation or who could not be followed up after surgery were excluded. Data was collected on demographics, clinical characteristics, anaesthesia technique and surgical factors, and date and time of admission, operation, first mobilisation and discharge. Results Of the 1040 patients included in the analysis, 264 received general anaesthesia only (Group GA), 322 received general anaesthesia with regional anaesthesia (Group GARA), and 454 received central neuraxial blockade anaesthesia with or without sedation (Group CNB). There was no significant difference in age (p = 0.56), sex (p = 0.23), number of comorbidities (p = 0.06), residential status (p = 0.18), time to surgery (p = 0.10) and length of hospital stay (p = 0.30) between the three groups. There was a statistically significant difference in ASA grade (p = 0.01), implant type used (p = 0.04), grade of operating surgeon (p = 0.02) and grade of anaesthetist during surgery (p = 0.004) among the three groups. Patients in Group GARA had a median time-to-first mobilisation of 23.8 hours after surgery, compared to 24.1 hours in Group GA and 24.3 hours in Group CNB. This difference was not statistically significant after controlling for confounding factors (p = 0.45). Conclusion Our results show that anaesthetic technique does not influence time-to-first mobilisation after hip fracture surgery

    Facile and inexpensive fabrication of zinc oxide based bio-surfaces for C-reactive protein detection

    Get PDF
    © 2018, The Author(s). The paper reports a biosensor formed from antibody coated ZnO nano-crystals which has been prepared using a rapid and inexpensive fabrication method which utilises colloidal dispersion enhanced using sonication. This technique was used to prepare highly ordered and uniform nano-crystalline sensor surfaces on polyethylene terephthalate (PET) using 0.5%, 1% and 5% concentrations of zinc oxide nano-crystal suspensions. Impedance spectroscopy was employed to interrogate the sensor surfaces and confirmed high reproducibility of the fabrication process. Changes in impedance values, at a frequency of 138 Hz, were used to establish dose dependent responses for C-reactive protein (CRP) antigen. A limit of detection of less than 1 ng/ml was demonstrated fornano-surfaces fabricated from concentrations of 1% ZnO

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components

    Changes in Lysozyme Flexibility upon Mutation Are Frequent, Large and Long-Ranged

    Get PDF
    We investigate changes in human c-type lysozyme flexibility upon mutation via a Distance Constraint Model, which gives a statistical mechanical treatment of network rigidity. Specifically, two dynamical metrics are tracked. Changes in flexibility index quantify differences within backbone flexibility, whereas changes in the cooperativity correlation quantify differences within pairwise mechanical couplings. Regardless of metric, the same general conclusions are drawn. That is, small structural perturbations introduced by single point mutations have a frequent and pronounced affect on lysozyme flexibility that can extend over long distances. Specifically, an appreciable change occurs in backbone flexibility for 48% of the residues, and a change in cooperativity occurs in 42% of residue pairs. The average distance from mutation to a site with a change in flexibility is 17–20 Å. Interestingly, the frequency and scale of the changes within single point mutant structures are generally larger than those observed in the hen egg white lysozyme (HEWL) ortholog, which shares 61% sequence identity with human lysozyme. For example, point mutations often lead to substantial flexibility increases within the β-subdomain, which is consistent with experimental results indicating that it is the nucleation site for amyloid formation. However, β-subdomain flexibility within the human and HEWL orthologs is more similar despite the lowered sequence identity. These results suggest compensating mutations in HEWL reestablish desired properties

    Vitamin D supplementation and breast cancer prevention : a systematic review and meta-analysis of randomized clinical trials

    Get PDF
    In recent years, the scientific evidence linking vitamin D status or supplementation to breast cancer has grown notably. To investigate the role of vitamin D supplementation on breast cancer incidence, we conducted a systematic review and meta-analysis of randomized controlled trials comparing vitamin D with placebo or no treatment. We used OVID to search MEDLINE (R), EMBASE and CENTRAL until April 2012. We screened the reference lists of included studies and used the “Related Article” feature in PubMed to identify additional articles. No language restrictions were applied. Two reviewers independently extracted data on methodological quality, participants, intervention, comparison and outcomes. Risk Ratios and 95% Confident Intervals for breast cancer were pooled using a random-effects model. Heterogeneity was assessed using the I2 test. In sensitivity analysis, we assessed the impact of vitamin D dosage and mode of administration on treatment effects. Only two randomized controlled trials fulfilled the pre-set inclusion criteria. The pooled analysis included 5372 postmenopausal women. Overall, Risk Ratios and 95% Confident Intervals were 1.11 and 0.74–1.68. We found no evidence of heterogeneity. Neither vitamin D dosage nor mode of administration significantly affected breast cancer risk. However, treatment efficacy was somewhat greater when vitamin D was administered at the highest dosage and in combination with calcium (Risk Ratio 0.58, 95% Confident Interval 0.23–1.47 and Risk Ratio 0.93, 95% Confident Interval 0.54–1.60, respectively). In conclusions, vitamin D use seems not to be associated with a reduced risk of breast cancer development in postmenopausal women. However, the available evidence is still limited and inadequate to draw firm conclusions. Study protocol code: FARM8L2B5L
    corecore