2,025 research outputs found

    The Expectation Monad in Quantum Foundations

    Get PDF
    The expectation monad is introduced abstractly via two composable adjunctions, but concretely captures measures. It turns out to sit in between known monads: on the one hand the distribution and ultrafilter monad, and on the other hand the continuation monad. This expectation monad is used in two probabilistic analogues of fundamental results of Manes and Gelfand for the ultrafilter monad: algebras of the expectation monad are convex compact Hausdorff spaces, and are dually equivalent to so-called Banach effect algebras. These structures capture states and effects in quantum foundations, and also the duality between them. Moreover, the approach leads to a new re-formulation of Gleason's theorem, expressing that effects on a Hilbert space are free effect modules on projections, obtained via tensoring with the unit interval.Comment: In Proceedings QPL 2011, arXiv:1210.029

    Markarian 421's Unusual Satellite Galaxy

    Get PDF
    We present Hubble Space Telescope (HST) imagery and photometry of the active galaxy Markarian 421 and its companion galaxy 14 arcsec to the ENE. The HST images indicate that the companion is a morphological spiral rather than elliptical as previous ground--based imaging has concluded. The companion has a bright, compact nucleus, appearing unresolved in the HST images. This is suggestive of Seyfert activity, or possibly a highly luminous compact star cluster. We also report the results of high dynamic range long-slit spectroscopy with the slit placed to extend across both galaxies and nuclei. We detect no emission lines in the companion nucleus, though there is evidence for recent star formation. Velocities derived from a number of absorption lines visible in both galaxies indicate that the two systems are probably tidally bound and thus in close physical proximity. Using the measured relative velocities, we derive a lower limit on the MKN 421 mass within the companion orbit (R \sim 10 kpc) of 5.9 \times 10^{11} solar masses, and a mass-to-light ratio of >= 17. Our spectroscopy also shows for the first time the presence of H\alpha and [NII] emission lines from the nucleus of MKN 421, providing another example of the appearance of new emission features in the previously featureless spectrum of a classical BL Lac object. We see both broad and narrow line emission, with a velocity dispersion of several thousand km s^{-1} evident in the broad lines.Comment: LaTeX (aaspp4 style), 28 pages, 8 figures, to appear in AJ. Revised text from ref. comments; new & modified figures; new photometry included; minor corrections of typos. Color version of Fig. 1 to appear in Feb. 2000 Sky & Telescop

    Ripple-locked coactivity of stimulus-specific neurons and human associative memory

    Get PDF
    Associative memory enables the encoding and retrieval of relations between different stimuli. To better understand its neural basis, we investigated whether associative memory involves temporally correlated spiking of medial temporal lobe (MTL) neurons that exhibit stimulus-specific tuning. Using single-neuron recordings from patients with epilepsy performing an associative object–location memory task, we identified the object-specific and place-specific neurons that represented the separate elements of each memory. When patients encoded and retrieved particular memories, the relevant object-specific and place-specific neurons activated together during hippocampal ripples. This ripple-locked coactivity of stimulus-specific neurons emerged over time as the patients’ associative learning progressed. Between encoding and retrieval, the ripple-locked timing of coactivity shifted, suggesting flexibility in the interaction between MTL neurons and hippocampal ripples according to behavioral demands. Our results are consistent with a cellular account of associative memory, in which hippocampal ripples coordinate the activity of specialized cellular populations to facilitate links between stimuli

    International Guillain-Barré Syndrome Outcome Study (IGOS): protocol of a prospective observational cohort study on clinical and biological predictors of disease course and outcome in Guillain-Barré syndrome

    Get PDF
    Guillain-Barré syndrome (GBS) is an acute polyradiculoneuropathy with a highly variable clinical presentation, course, and outcome. The factors that determine the clinical variation of GBS are poorly understood which complicates the care and treatment of individual patients. The protocol of the ongoing International GBS Outcome Study (IGOS), a prospective, observational, multi-centre cohort study that aims to identify the clinical and biological determinants and predictors of disease onset, subtype, course and outcome of GBS is presented here. Patients fulfilling the diagnostic criteria for GBS, regardless of age, disease severity, variant forms, or treatment, can participate if included within two weeks after onset of weakness. Information about demography, preceding infections, clinical features, diagnostic findings, treatment, course and outcome is collected. In addition, cerebrospinal fluid and serial blood samples for serum and DNA is collected at standard time points. The original aim was to include at least 1000 patients with a follow-up of 1-3 years. Data are collected via a web-based data entry system and stored anonymously. IGOS started in May 2012 and by January 2017 included more than 1400 participants from 143 active centres in 19 countries across 5 continents. The IGOS data/biobank is available for research projects conducted by expertise groups focusing on specific topics including epidemiology, diagnostic criteria, clinimetrics, electrophysiology, antecedent events, antibodies, genetics, prognostic modelling, treatment effects and long-term outcome of GBS. The IGOS will help to standardize the international collection of data and biosamples for future research of GBS. ClinicalTrials.gov Identifier: NCT01582763

    Quantum teleportation on a photonic chip

    Full text link
    Quantum teleportation is a fundamental concept in quantum physics which now finds important applications at the heart of quantum technology including quantum relays, quantum repeaters and linear optics quantum computing (LOQC). Photonic implementations have largely focussed on achieving long distance teleportation due to its suitability for decoherence-free communication. Teleportation also plays a vital role in the scalability of photonic quantum computing, for which large linear optical networks will likely require an integrated architecture. Here we report the first demonstration of quantum teleportation in which all key parts - entanglement preparation, Bell-state analysis and quantum state tomography - are performed on a reconfigurable integrated photonic chip. We also show that a novel element-wise characterisation method is critical to mitigate component errors, a key technique which will become increasingly important as integrated circuits reach higher complexities necessary for quantum enhanced operation.Comment: Originally submitted version - refer to online journal for accepted manuscript; Nature Photonics (2014

    Hepatic angiotensin-converting enzyme 2 expression in metabolic dysfunction-associated steatotic liver disease and in patients with fatal COVID-19

    Get PDF
    BACKGROUND Metabolic dysfunction-associated steatotic liver disease (MASLD), characterised by hepatic lipid accumulation, causes inflammation and oxidative stress accompanied by cell damage and fibrosis. Liver injury (LI) is also frequently reported in patients hospitalised with coronavirus disease 2019 (COVID-19), while preexisting MASLD increases the risk of LI and the development of COVID-19associated cholangiopathy. Mechanisms of injury at the cellular level remain unclear, but it may be significant that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which causes COVID-19, uses angiotensin-converting expression enzyme 2 (ACE2), a key regulator of the ‘anti-inflammatory’ arm of the renin-angiotensin system, for viral attachment and host cell invasion. AIM To determine if hepatic ACE2 levels are altered during progression of MASLD and in patients who died with severe COVID-19. METHODS ACE2 protein levels and localisation, and histological fibrosis and lipid droplet accumulation as markers of MASLD were determined in formalin-fixed liver tissue sections across the MASLD pathological spectrum (isolated hepatocellular steatosis, metabolic dysfunction-associated steatohepatitis (MASH) +/- fibrosis, end-stage cirrhosis) and in post-mortem tissues from patients who had died with severe COVID-19, using ACE2 immunohistochemistry and haematoxylin and eosin and picrosirius red staining of total collagen and lipid droplet areas, followed by quantification using machine learning-based image pixel classifiers. RESULTS ACE2 staining is primarily intracellular and concentrated in the cytoplasm of centrilobular hepatocytes and apical membranes of bile duct cholangiocytes. Strikingly, ACE2 protein levels are elevated in non-fibrotic MASH compared to healthy controls but not in the progression to MASH with fibrosis and in cirrhosis. ACE2 protein levels and histological fibrosis are not associated, but ACE2 and liver lipid droplet content are significantly correlated across the MASLD spectrum. Hepatic ACE2 levels are also increased in COVID-19 patients, especially those showing evidence of LI, but are not correlated with the presence of SARS-CoV-2 virus in the liver. However, there is a clear association between the hepatic lipid droplet content and the presence of the virus, suggesting a possible functional link. CONCLUSION Hepatic ACE2 levels were elevated in nonfibrotic MASH and COVID-19 patients with LI, while lipid accumulation may promote intra-hepatic SARS-CoV-2 replication, accelerating MASLD progression and COVID-19-mediated liver damage.</p

    An improved quantitative measure of the tendency for volcanic ash plumes to form in water: implications for the deposition of marine ash beds

    No full text
    Laboratory experiments and numerical simulations have shown that volcanic ash particles immersed in water can either settle slowly and individually, or rapidly and collectively as particle-laden plumes. The ratio of timescales for individual and collective settling, in the form of analytical expressions, provides a dimensionless quantitative measure of the tendency for such plumes to grow and persist which has important implications for determining particle residence times and deposition rates. However, existing measures in the literature assume that collective settling obeys Stokes' law and is therefore controlled by the balance between gravitational forces and viscous drag, despite plume development actually being controlled by the balance between gravitational forces and inertial drag even in the absence of turbulence during early times. This paper presents a new measure for plume onset which takes into account the inertial drag-controlled (rather than viscous drag-controlled) nature of plume growth and descent. A parameter study comprising a set of numerical simulations of small-scale volcanic ash particle settling experiments highlights the effectiveness of the new measure and, by comparison with an existing measure in the literature, also demonstrates that the timescale of collective settling is grossly under-estimated when assuming that plume development is slowed by viscous drag. Furthermore, the formulation of the new measure means that the tendency for plumes to form can be estimated from the thickness and concentration of the final deposit; the magnitude and duration of particle flux across the water's surface do not need to be known. The measure therefore permits the residence times of particles in a large body of water to be more accurately and practically determined, and allows the improved interpretation of layers of volcaniclastic material deposited at the seabed

    Prediction of Cardiovascular Events by Using Non-Vascular Findings on Routine Chest CT

    Get PDF
    Background: Routine computed tomography (CT) examinations contain an abundance of findings unrelated to the diagnostic question. Those with prognostic significance may contribute to early detection and treatment of disease, irrelevant findings can be ignored. We aimed to assess the association between unrequested chest CT findings in lungs, mediastinum and pleura and future cardiovascular events. Methods: Multi-center case-cohort study in 5 tertiary and 3 secondary care hospitals involving 10410 subjects who underwent routine chest CT for non-cardiovascular reasons. 493 cardiovascular hospitalizations or deaths were recorded during an average follow-up time of 17.8 months. 1191 patients were randomly sampled to serve as a control subcohort. Hazard ratios and annualized event rates were calculated. Results: Abnormalities in the lung (26–44%), pleura (14–15%) and mediastinum (20%) were common. Hazard ratios after adjustment for age and sex were for airway wall thickening 2.26 (1.59–3.22), ground glass opacities 2.50 (1.72–3.62), consolidations 1.97 (1.12–3.47), pleural effusions 2.77 (1.81–4.25) and lymph-nodes 2.04 (1.40–2.96). Corresponding annual event rates were 5.5%, 6.0%, 3.8%, 10.2 % and 4.4%. Conclusions: We have identified several common chest CT findings that are predictive for future risk of cardiovascular events and found that other findings have little utility for this. The added value of the non-vascular predictors to establishe

    Quantitative, Simultaneous PET/MRI for Intratumoral Imaging with an MRI-Compatible PET Scanner

    Get PDF
    Noninvasive methods are needed to explore the heterogeneous tumor microenvironment and its modulation by therapy. Hybrid PET/MRI systems are being developed for small-animal and clinical use. The advantage of these integrated systems depends on their ability to provide MR images that are spatially coincident with simultaneously acquired PET images, allowing combined functional MRI and PET studies of intratissue heterogeneity. Although much effort has been devoted to developing this new technology, the issue of quantitative and spatial fidelity of PET images from hybrid PET/MRI systems to the tissues imaged has received little attention. Here, we evaluated the ability of a first-generation, small-animal MRI-compatible PET scanner to accurately depict heterogeneous patterns of radiotracer uptake in tumors. Methods: Quantitative imaging characteristics of the MRI-compatible PET (PET/MRI) scanner were evaluated with phantoms using calibration coefficients derived from a mouse-sized linearity phantom. PET performance was compared with a commercial small-animal PET system and autoradiography in tumor-bearing mice. Pixel and structure-based similarity metrics were used to evaluate image concordance among modalities. Feasibility of simultaneous PET/MRI functional imaging of tumors was explored by following ^(64)Cu-labeled antibody uptake in relation to diffusion MRI using cooccurrence matrix analysis. Results: The PET/MRI scanner showed stable and linear response. Activity concentration recovery values (measured and true activity concentration) calculated for 4-mm-diameter rods within linearity and uniform activity rod phantoms were near unity (0.97 ± 0.06 and 1.03 ± 0.03, respectively). Intratumoral uptake patterns for both ^(18)F-FDG and a ^(64)Cu-antibody acquired using the PET/MRI scanner and small-animal PET were highly correlated with autoradiography (r > 0.99) and with each other (r = 0.97 ± 0.01). On the basis of these data, we performed a preliminary study comparing diffusion MRI and radiolabeled antibody uptake patterns over time and visualized movement of antibodies from the vascular space into the tumor mass. Conclusion: The MRI-compatible PET scanner provided tumor images that were quantitatively accurate and spatially concordant with autoradiography and the small-animal PET examination. Cooccurrence matrix approaches enabled effective analysis of multimodal image sets. These observations confirm the ability of the current simultaneous PET/MRI system to provide accurate observations of intratumoral function and serve as a benchmark for future evaluations of hybrid instrumentation
    corecore