34,688 research outputs found

    Modification to the Automatic Ionization Chamber

    Get PDF
    The automatic ionization chamber has been described previously [1,2]. It has proven quite reliable in service and has many desirable features, especially for balloon-borne equipment. A disadvantage has been that the time of discharge was dependent upon the potential applied to the quartz fiber. Thus, during the comparison of the instrument to be used with the standards, careful measurement of the potential used on the standards was required. Furthermore, care was required to make sure that the battery used during the flight remained constant in potential. It has now been found that the time between rechargings can be made nearly independent of the potential of the fiber by inserting a metal conductor inside and insulating it from the outer conductor surrounding the quartz fiber, and making the potential of this inner conductor the same as that of the fiber

    A tough high performance composite matrix

    Get PDF
    This invention is a semi-interpenetrating polymer network which includes a high performance thermosetting polyimide having a nadic end group acting as a crosslinking site and a high performance linear thermoplastic polyimide. An improved high temperature matrix resin is provided which is capable of performing in the 200 to 300 C range. This resin has significantly improved toughness and microcracking resistance, excellent processability, mechanical performance and moisture and solvent resistances

    Pneumatic inflatable end effector

    Get PDF
    The invention relates to an end effector device for robot or teleoperated type space vehicle which includes an inflatable balloon member carried on the end of tubular member which has a hollow center or conduit through which a suitable pressurized fluid is supplied. The device may be inserted into a variety of shaped openings or truss-type structures for handling in space

    Laser net - A concept for monitoring wingtip vortices on runways

    Get PDF
    Network of laser beams passes over runway to photodetectors on opposite side, magnitude of beam deflection indicates magnitude of density gradient encountered. Visual display of beam deflections affects go, no-go decision for takeoff and landing

    Techniques Useful in Evacuating and Pressurizing Metal Chambers

    Get PDF
    The aforementioned problems arose in connection with the automatic ionization chamber described previously (1). It was fund that the functioning of these instruments was more consistent if the ion chamber was baked at 350°C for several hours and then filled with pure argon. This procedure resulted in the elimination of organic impurities from the inner surfaces. The impurities, settling on the gold-coated quartz fiber and the collector, apparently altered the contact, resulting in some uncertainty in the recharging. The baking procedure has completely curved this difficulty

    Manual and automatic flight control during severe turbulence penetration

    Get PDF
    An analytical and experimental investigation of possible contributing factors in jet aircraft turbulence upsets was conducted. Major contributing factors identified included autopilot and display deficiencies, the large aircraft inertia and associated long response time, and excessive pilot workload. An integrated flight and thrust energy management director system was synthesized. The system was incorporated in a moving-base simulation and evaluated using highly experienced airline pilots. The evaluation included comparison of pilot workload and flight performance during severe turbulence penetration utilizing four control/display concepts: manual control with conventional full panel display, conventional autopilot (A/P-A) with conventional full panel display, improved autopilot (A/P-B) with conventional full panel display plus thrust director display, and longitudinal flight director with conventional full panel display plus thrust director display. Simulation results show improved performance, reduced pilot workload, and a pilot preference for the autopilot system controlling to the flight director command and manual control of thrust following the trim thrust director

    The 2007-2008 World Food Crisis: Focusing on the Structural Causes

    Get PDF

    Distribution automation applications of fiber optics

    Get PDF
    Motivations for interest and research in distribution automation are discussed. The communication requirements of distribution automation are examined and shown to exceed the capabilities of power line carrier, radio, and telephone systems. A fiber optic based communication system is described that is co-located with the distribution system and that could satisfy the data rate and reliability requirements. A cost comparison shows that it could be constructed at a cost that is similar to that of a power line carrier system. The requirements for fiber optic sensors for distribution automation are discussed. The design of a data link suitable for optically-powered electronic sensing is presented. Empirical results are given. A modeling technique that was used to understand the reflections of guided light from a variety of surfaces is described. An optical position-indicator design is discussed. Systems aspects of distribution automation are discussed, in particular, the lack of interface, communications, and data standards. The economics of distribution automation are examined

    Effect of exposure cycle on hot salt stress corrosion of a titanium alloy

    Get PDF
    The influence of exposure cycle on the hot-salt stress-corrosion cracking resistance of the Ti-8Al-1Mo-1V alloy was determined. Both temperature and stress were cycled simultaneously to simulate turbine-powered aircraft service cycles. Temperature and stress were also cycled independently to determine their individual effects. Substantial increases in crack threshold stresses were observed for cycles in which both temperature and stress or temperature alone were applied for 1 hour and removed for 3 hours. The crack threshold stresses for these cyclic exposures were twice those determined for continuous exposure for the same total time of 96 hours

    Impaired Dendritic Expression and Plasticity Of H-Channels in the fmr1(-/Y) Mouse Model of Fragile X Syndrome

    Get PDF
    Despite extensive research into both synaptic and morphological changes, surprisingly little is known about dendritic function in fragile X syndrome (FXS). We found that the dendritic input resistance of CA1 neurons was significantly lower in fmr1(-/y) versus wild-type mice. Consistent with elevated dendritic I-h, voltage sag, rebound, and resonance frequency were significantly higher and temporal summation was lower in the dendrites of fmr1(-/y) mice. Dendritic expression of the h-channel subunit HCN1, but not HCN2, was higher in the CA1 region of fmr1(-/y) mice. Interestingly, whereas mGluR-mediated persistent decreases in Ih occurred in both wildtype and fmr1(-/y) mice, persistent increases in Ih that occurred after LTP induction in wild-type mice were absent in fmr1(-/y) mice. Thus, chronic upregulation of dendritic Ih in conjunction with impairment of homeostatic h-channel plasticity represents a dendritic channelopathy in this model of mental retardation and may provide a mechanism for the cognitive impairment associated with FXS.FRAXAUniversity of Texas Austin Undergraduate Research FellowshipNational Institutes of Health Grant MH048432Center for Learning and Memor
    corecore