227 research outputs found

    The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    Get PDF
    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume < 70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution.Vascular Biology and Interventio

    Impact of disaster-related mortality on gross domestic product in the WHO African Region

    Get PDF
    BACKGROUND: Disaster-related mortality is a growing public health concern in the African Region. These deaths are hypothesized to have a significantly negative effect on per capita gross domestic product (GDP). The objective of this study was to estimate the loss in GDP attributable to natural and technological disaster-related mortality in the WHO African Region. METHODS: The impact of disaster-related mortality on GDP was estimated using double-log econometric model and cross-sectional data on various Member States in the WHO African Region. The analysis was based on 45 of the 46 countries in the Region. The data was obtained from various UNDP and World Bank publications. RESULTS: The coefficients for capital (K), educational enrolment (EN), life expectancy (LE) and exports (X) had a positive sign; while imports (M) and disaster mortality (DS) were found to impact negatively on GDP. The above-mentioned explanatory variables were found to have a statistically significant effect on GDP at 5% level in a t-distribution test. Disaster mortality of a single person was found to reduce GDP by US$0.01828. CONCLUSIONS: We have demonstrated that disaster-related mortality has a significant negative effect on GDP. Thus, as policy-makers strive to increase GDP through capital investment, export promotion and increased educational enrolment, they should always keep in mind that investments made in the strengthening of national capacity to mitigate the effects of national disasters expeditiously and effectively will yield significant economic returns

    Small average differences in attenuation corrected images between men and women in myocardial perfusion scintigraphy: a novel normal stress database

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy. However, commonly used software packages for MPS usually include normal stress databases for non-attenuation corrected (NC) images but not for attenuation-corrected (AC) images. The aim of the study was to develop and compare different normal stress databases for MPS in relation to NC vs. AC images, male vs. female gender, and presence vs. absence of obesity. The principal hypothesis was that differences in mean count values between men and women would be smaller with AC than NC images, thereby allowing for construction and use of gender-independent AC stress database.</p> <p>Methods</p> <p>Normal stress perfusion databases were developed with data from 126 male and 205 female patients with normal MPS. The following comparisons were performed for all patients and separately for normal weight vs. obese patients: men vs. women for AC; men vs. women for NC; AC vs. NC for men; and AC vs. NC for women.</p> <p>Results</p> <p>When comparing AC for men vs. women, only minor differences in mean count values were observed, and there were no differences for normal weight vs. obese patients. For all other analyses major differences were found, particularly for the inferior wall.</p> <p>Conclusions</p> <p>The results support the hypothesis that it is possible to use not only gender independent but also weight independent AC stress databases.</p

    Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages

    Get PDF
    Abstract Background We sought to compare quantification of left ventricular volumes and ejection fraction by different gated myocardial perfusion SPECT (MPS) programs with each other and to magnetic resonance (MR) imaging. Methods N = 100 patients with known or suspected coronary artery disease were examined at rest with 99 mTc-tetrofosmin gated MPS and cardiac MR imaging. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were obtained by analysing gated MPS data with four different programs: Quantitative Gated SPECT (QGS), GE MyoMetrix, Emory Cardiac Toolbox (ECTb) and Exini heart. Results All programs showed a mean bias compared to MR imaging of approximately -30% for EDV (-22 to -34%, p Conclusions Gated MPS, systematically underestimates left ventricular volumes by approximately 30% and shows a high variability, especially for ESV. For EF, accuracy was better, with a mean bias between -15 and 6% of EF. It may be of value to take this into consideration when determining absolute values of LV volumes and EF in a clinical setting.</p

    Triple-gated motion and blood pool clearance corrections improve reproducibility of coronary 18F-NaF PET

    Get PDF
    PurposeTo improve the test-retest reproducibility of coronary plaque 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) uptake measurements.MethodsWe recruited 20 patients with coronary artery disease who underwent repeated hybrid PET/CT angiography (CTA) imaging within 3&nbsp;weeks. All patients had 30-min PET acquisition and CTA during a single imaging session. Five PET image-sets with progressive motion correction were reconstructed: (i) a static dataset (no-MC), (ii) end-diastolic PET (standard), (iii) cardiac motion corrected (MC), (iv) combined cardiac and gross patient motion corrected (2 × MC) and, (v) cardiorespiratory and gross patient motion corrected (3 × MC). In addition to motion correction, all datasets were corrected for variations in the background activities which are introduced by variations in the injection-to-scan delays (background blood pool clearance correction, BC). Test-retest reproducibility of PET target-to-background ratio (TBR) was assessed by Bland-Altman analysis and coefficient of reproducibility.ResultsA total of 47 unique coronary lesions were identified on CTA. Motion correction in combination with BC improved the PET TBR test-retest reproducibility for all lesions (coefficient of reproducibility: standard = 0.437, no-MC = 0.345 (27% improvement), standard&nbsp;+&nbsp;BC = 0.365 (20% improvement), no-MC + BC = 0.341 (27% improvement), MC + BC = 0.288 (52% improvement), 2 × MC + BC = 0.278 (57% improvement) and 3 × C + BC = 0.254 (72% improvement), all p &lt; 0.001). Importantly, in a sub-analysis of 18F-NaF-avid lesions with gross patient motion &gt;&nbsp;10&nbsp;mm following corrections, reproducibility was improved by 133% (coefficient of reproducibility: standard = 0.745, 3 × MC = 0.320).ConclusionJoint corrections for cardiac, respiratory, and gross patient motion in combination with background blood pool corrections markedly improve test-retest reproducibility of coronary 18F-NaF PET

    Usefulness of real time PCR for the differentiation and quantification of 652 and JP2 Actinobacillus actinomycetemcomitans genotypes in dental plaque and saliva

    Get PDF
    BACKGROUND: The aim of our study is to describe a fast molecular method, able to distinguish and quantize the two different genotypes (652 and JP2) of an important periodontal pathogen: Actinobacillus actinomycetemcomitans. The two genotypes show differences in the expression of an important pathogenic factor: the leukotoxin (ltx). In order to evidence this, we performed a real time PCR procedure on the ltx operon, able to recognize Aa clinical isolates with different leukotoxic potentials. METHODS: The specificity of the method was confirmed in subgingival plaque and saliva specimens collected from eighty-one Italian (Sardinian) subjects with a mean age of 43.9, fifty five (68 %) of whom had various clinical forms of periodontal disease. RESULTS: This procedure showed a good sensitivity and a high linear dynamic range of quantization (10(7)-10(2 )cells/ml) for all genotypes and a good correlation factor (R2 = 0.97–0.98). Compared with traditional cultural methods, this real time PCR procedure is more sensitive; in fact in two subgingival plaque and two positive saliva specimens Aa was only detected with the molecular method. CONCLUSION: A low number of Sardinian patients was found positive for Aa infections in the oral cavity, (just 10 positive periodontal cases out of 81 and two of these were also saliva positive). The highly leukotoxic JP2 strain was the most representative (60 % of the positive specimens); the samples from periodontal pockets and from saliva showed some ltx genotype for the same patient. Our experience suggests that this approach is suitable for a rapid and complete laboratory diagnosis for Aa infection
    corecore