80 research outputs found
Cost-effectiveness analysis of 3-D computerized tomography colonography versus optical colonoscopy for imaging symptomatic gastroenterology patients.
BACKGROUND: When symptomatic gastroenterology patients have an indication for colonic imaging, clinicians have a choice between optical colonoscopy (OC) and computerized tomography colonography with three-dimensional reconstruction (3-D CTC). 3-D CTC provides a minimally invasive and rapid evaluation of the entire colon, and it can be an efficient modality for diagnosing symptoms. It allows for a more targeted use of OC, which is associated with a higher risk of major adverse events and higher procedural costs. A case can be made for 3-D CTC as a primary test for colonic imaging followed if necessary by targeted therapeutic OC; however, the relative long-term costs and benefits of introducing 3-D CTC as a first-line investigation are unknown. AIM: The aim of this study was to assess the cost effectiveness of 3-D CTC versus OC for colonic imaging of symptomatic gastroenterology patients in the UK NHS. METHODS: We used a Markov model to follow a cohort of 100,000 symptomatic gastroenterology patients, aged 50 years or older, and estimate the expected lifetime outcomes, life years (LYs) and quality-adjusted life years (QALYs), and costs (£, 2010-2011) associated with 3-D CTC and OC. Sensitivity analyses were performed to assess the robustness of the base-case cost-effectiveness results to variation in input parameters and methodological assumptions. RESULTS: 3D-CTC provided a similar number of LYs (7.737 vs 7.739) and QALYs (7.013 vs 7.018) per individual compared with OC, and it was associated with substantially lower mean costs per patient (£467 vs £583), leading to a positive incremental net benefit. After accounting for the overall uncertainty, the probability of 3-D CTC being cost effective was around 60 %, at typical willingness-to-pay values of £20,000-£30,000 per QALY gained. CONCLUSION: 3-D CTC is a cost-saving and cost-effective option for colonic imaging of symptomatic gastroenterology patients compared with OC
Screening for colorectal cancer: random comparison of guaiac and immunochemical faecal occult blood testing at different cut-off levels
Immunochemical faecal occult blood testing (FIT) provides quantitative test results, which allows optimisation of the cut-off value for follow-up colonoscopy. We conducted a randomised population-based trial to determine test characteristics of FIT (OC-Sensor micro, Eiken, Japan) screening at different cut-off levels and compare these with guaiac-based faecal occult blood test (gFOBT) screening in an average risk population. A representative sample of the Dutch population (n=10 011), aged 50–74 years, was 1 : 1 randomised before invitation to gFOBT and FIT screening. Colonoscopy was offered to screenees with a positive gFOBT or FIT (cut-off 50 ng haemoglobin/ml). When varying the cut-off level between 50 and 200 ng ml−1, the positivity rate of FIT ranged between 8.1% (95% CI: 7.2–9.1%) and 3.5% (95% CI: 2.9–4.2%), the detection rate of advanced neoplasia ranged between 3.2% (95% CI: 2.6–3.9%) and 2.1% (95% CI: 1.6–2.6%), and the specificity ranged between 95.5% (95% CI: 94.5–96.3%) and 98.8% (95% CI: 98.4–99.0%). At a cut-off value of 75 ng ml−1, the detection rate was two times higher than with gFOBT screening (gFOBT: 1.2%; FIT: 2.5%; P<0.001), whereas the number needed to scope (NNscope) to find one screenee with advanced neoplasia was similar (2.2 vs 1.9; P=0.69). Immunochemical faecal occult blood testing is considerably more effective than gFOBT screening within the range of tested cut-off values. From our experience, a cut-off value of 75 ng ml−1 provided an adequate positivity rate and an acceptable trade-off between detection rate and NNscope
Population screening for colorectal cancer: the implications of an ageing population
Population screening for colorectal cancer (CRC) has recently commenced in the United Kingdom supported by the evidence of a number of randomised trials and pilot studies. Certain factors are known to influence screening cost-effectiveness (e.g. compliance), but it remains unclear whether an ageing population (i.e. demographic change) might also have an effect. The aim of this study was to simulate a population-based screening setting using a Markov model and assess the effect of increasing life expectancy on CRC screening cost-effectiveness. A Markov model was constructed that aimed, using a cohort simulation, to estimate the cost-effectiveness of CRC screening in an England and Wales population for two timescales: 2003 (early cohort) and 2033 (late cohort). Four model outcomes were calculated; screened and non-screened cohorts in 2003 and 2033. The screened cohort of men and women aged 60 years were offered biennial unhydrated faecal occult blood testing until the age of 69 years. Life expectancy was assumed to increase by 2.5 years per decade. There were 407 552 fewer people entering the model in the 2033 model due to a lower birth cohort, and population screening saw 30 345 fewer CRC-related deaths over the 50 years of the model. Screening the 2033 cohort cost £96 million with cost savings of £43 million in terms of detection and treatment and £28 million in palliative care costs. After 30 years of follow-up, the cost per life year saved was £1544. An identical screening programme in an early cohort (2003) saw a cost per life year saved of £1651. Population screening for CRC is costly but enables cost savings in certain areas and a considerable reduction in mortality from CRC. This Markov simulation suggests that the cost-effectiveness of population screening for CRC in the United Kingdom may actually be improved by rising life expectancies
Colon cancer in Luxembourg: a national population-based data report, 1988–1998
BACKGROUND: Over the last two decades time trends in incidence rates of colorectal cancer, changes in the proportions of stage at diagnosis and changes in the anatomic sub-site distribution of colon cancers have been reported in some European countries. In order to determine a strategy for early detection of colon cancer in the Grand-Duchy of Luxembourg, all consecutive colon adenocarcinomas diagnosed during the period 1988–1998 at a nation-wide level were reviewed. METHODS: The population-based data of the national Morphologic Tumour Registry report all new high-grade adenomas (i.e. high-grade intraepithelial adenomatous neoplasias) and all consecutive new invasive adenocarcinomas of the colon diagnosed in the central department of pathology. Attention has been focused on variations in incidence, stage, anatomical site distribution and survival rates. Rectal cancers were excluded. RESULTS: Over the study period, 254 new colonic high-grade adenomas and 1379 new invasive adenocarcinomas were found; the crude incidence rates of colon adenocarcinomas grew steadily by 30%. Comparing the two 5-year periods 1988–1992 and 1994–1998, the crude incidence rates of high-grade adenomas (stage 0) rose by 190%, that of stage I cases by 14.3%, stage II cases 12.9% and stage III cases 38.5%, whereas the crude incidence rates of stage IV cases decreased by 11.8%. The high-grade adenoma/adenocarcinoma ratio increased. The right-sided colonic adenocarcinomas in elderly patients (>69 years) increased by 76%. The observed survival rates correlated with tumour stages. The overall observed 5-year survival rate (stage I-IV) was 51 ± 3% (95% confidence interval). CONCLUSION: The increasing incidence rates of colon adenocarcinomas, the persistence of advanced tumour stages (stage III), the mortality rates which remain stable, and the changing trends in the age- and sub-site distribution underline the need for preventive measures at the age of 50 in asymptomatic patients to reduce mortality from colo(rectal) cancer
Serum CD26 is related to histopathological polyp traits and behaves as a marker for colorectal cancer and advanced adenomas
<p>Abstract</p> <p>Background</p> <p>Serum CD26 (sCD26) levels were previously found diminished in colorectal cancer (CRC) patients compared to healthy donors, suggesting its potential utility for early diagnosis. Therefore we aimed to estimate the utility of the sCD26 as a biomarker for CRC and advanced adenomas in a high-risk group of patients. The relationship of this molecule with polyp characteristics was also addressed.</p> <p>Methods</p> <p>sCD26 levels were measured by ELISA in 299 symptomatic and asymptomatic patients who had undergone a colonoscopy. Patients were diagnosed as having no colorectal pathology, non-inflammatory or inflammatory bowel disease, polyps (hyperplastic, non-advanced and advanced adenomas) or CRC.</p> <p>Results</p> <p>At a 460 ng/mL cut-off, the sCD26 has a sensitivity and specificity of 81.8% (95% CI, 64.5-93.0%) and 72.3% (95% CI, 65.0-77.2%) for CRC regarding no or benign colorectal pathology. Clinicopathological analysis of polyps showed a relationship between the sCD26 and the grade of dysplasia and the presence of advanced adenomas. Hence, a 58.0% (95% CI, 46.5-68.9%) sensitivity detecting CRC and advanced adenomas was obtained, with a specificity of 75.5% (95% CI, 68.5-81.0%).</p> <p>Conclusions</p> <p>Our preliminary results show that measurement of the sCD26 is a non-invasive and reasonably sensitive assay, which could be combined with others such as the faecal occult blood test for the early diagnosis and screening of CRC and advanced adenomas. Additional comparative studies in average-risk populations are necessary.</p
Recommended from our members
Low-level mediation of directionally specific motion after-effects: motion perception is not necessary
Previous psychophysical experiments with normal human observers have shown that adaptation to a moving dot stream causes directionally specific repulsion in the perceived angle of a subsequently viewed, moving probe. In this paper, we used a 2AFC task with roving pedestals to determine the conditions necessary and sufficient for producing directionally specific repulsion with compound adaptors, each ofwhich contains two oppositely moving, differently colored, component streams. Experiment 1 provides a demonstration of repulsion between single-component adaptors and probes moving at approximately 90° or 270°. In Experiment 2 oppositely moving dots in the adaptor were paired to preclude the appearance of motion. Nonetheless, repulsion remained strong when the angle betweeneach probe stream and one component was approximately 30°. In Experiment 3 adapting dot-pairs were kept stationary during their limited lifetimes. Their orientation content alone proved insufficient for producing repulsion. In Experiments 4-6 the angle between probe and both adapting components was approximately 90°or 270°. Directional repulsion was found when observers were asked to visually track one of the adapting components (Experiment 6), but not when observers were asked to attentionally track it (Experiment 5), nor while passively viewing the adaptor (Experiment 4). Our results are consistent with a low-level mechanism for motion adaptation. It is not selective for stimulus color and it is not susceptible to attentional modulation.The most likely cortical locus of adaptation is area V1
Making the Invisible Visible: Verbal but Not Visual Cues Enhance Visual Detection
Background: Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. Methodology/Principal Findings: Participants completed an object detection task in which they made an object-presence or-absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d9). A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. Conclusions/Significance: Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affect
Does CT colonography have a role for population-based colorectal cancer screening?
Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. CRC screening has been proven to reduce disease-specific mortality and several European countries employ national screening programmes. These almost exclusively rely on stool tests, with endoscopy used as an adjunct in some countries. Computed tomographic colonography (CTC) is a potential screening test, with an estimated sensitivity of 88 % for advanced neoplasia ≥10 mm. Recent randomised studies have shown that CTC and colonoscopy have similar yields of advanced neoplasia per screened invitee, indicating that CTC is potentially viable as a primary screening test. However, the evidence is not fully elaborated. It is unclear whether CTC screening is cost-effective and the impact of extracolonic findings, both medical and economic, remains unknown. Furthermore, the effect of CTC screening on CRC-related mortality is unknown, as it is also unknown for colonoscopy. It is plausible that both techniques could lead to decreased mortality, as for sigmoidoscopy and gFOBT. Although radiation exposure is a drawback, this disadvantage may be over-emphasised. In conclusion, the detection characteristics and acceptability of CTC suggest it is a viable screening investigation. Implementation will depend on detection of extracolonic disease and health-economic impact
- …