29 research outputs found

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6路9 per cent) from low-HDI, 254 (15路5 per cent) from middle-HDI and 1268 (77路6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57路5, 40路9 and 35路4 per cent; P < 0路001) and subsequent use of end colostomy (52路2, 24路8 and 18路9 per cent; P < 0路001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3路20, 95 per cent c.i. 1路35 to 7路57; P = 0路008) after risk adjustment for malignant disease (OR 2路34, 1路65 to 3路32; P < 0路001), emergency surgery (OR 4路08, 2路73 to 6路10; P < 0路001), time to operation at least 48 h (OR 1路99, 1路28 to 3路09; P = 0路002) and disease perforation (OR 4路00, 2路81 to 5路69; P < 0路001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Externe versie

    No full text

    Accuracy of fibronectin tests for the prediction of pre-eclampsia: a systematic review

    No full text
    The purpose of this study was to review systematically all studies that assessed the accuracy of maternal plasma fibronectin as a serum marker for early prediction of pre-eclampsia. We therefore assessed studies that reported on fibronectin as serum marker for pre-eclampsia before the 25th gestational week. For the selected studies, sensitivity and specificity were calculated and plotted in ROC-space. We included 12 studies, of which only 5 studies reported sufficient data to calculate accuracy estimates, such as sensitivity and specificity. These five studies reported on 573 pregnant women of whom 109 developed pre-eclampsia. At a sensitivity of at least 50%, specificities ranged between 72 and 96% for cellular fibronectin. For total fibronectin, these numbers were 42-94%. Fibronectin seems to be a promising marker for the prediction of pre-eclampsia, however, further studies are needed to determine whether the accuracy of this test is sufficient to be clinically relevan

    Transvaginal sonographic assessment of cervical length and wedging for predicting outcome of labor induction at tem : a systematic review and meta-analysis

    No full text
    Methods We searched MEDLINE, EMBASE and the Cochrane Library, and manually searched reference lists of review articles and eligible primary articles. Studies in all languages were eligible if published in full. Two reviewers independently selected studies and extracted data on study characteristics, quality and test accuracy. We then calculated pooled sensitivities and specificities (with 95% CIs) and summary receiver鈥搊perating characteristics (sROC) curves. Outcome measures were test accuracy of sonographically measured cervical length and cervical wedging for Cesarean section, not achieving vaginal delivery within 24驴h and not achieving active labor. Results We included 31 studies reporting on both cervical length and outcome of delivery. The quality of the included studies was mediocre. Sensitivity of cervical length in the prediction of Cesarean delivery ranged from 0.14 to 0.92 and specificity ranged from 0.35 to 1.00. The estimated sROC curve for cervical length indicated a limited predictive capacity in the prediction of Cesarean delivery. Summary estimates of sensitivity/specificity combinations of cervical length at different cut-offs for Cesarean delivery were 0.82/0.34, 0.64/0.74 and 0.13/0.95 for 20, 30 and 40驴mm, respectively. For cervical wedging in the prediction of failed induction of labor summary point estimates of sensitivity/specificity were 0.37/0.80. Conclusions Cervical length and cervical wedging as measured sonographically at or near term have moderate capacity to predict the outcome of delivery after induction of labo
    corecore