3,297 research outputs found

    PMH1 The Economic Burden of Schizophrenia: Acute General Hospital Costs

    Get PDF

    Overdose risk perceptions and experience of overdose among heroin users in Cork, Ireland. Preliminary results from a pilot overdose prevention study

    Get PDF
    Background. Opioid overdose is the primary cause of death among injecting drug users (IDU). Overdose is generally not sudden, occurs over one to three hours, and often in the presence of bystanders. This presents a unique window of opportunity to intervene. Aim. Successful overdose prevention training includes appropriate clinical and non-clinical responses. The study aimed to investigate Irish IDU experience of overdose, and need for education and resuscitation skills programming. We report on pilot findings. Methods. Phase One assessed service user experience of overdose, substances used, setting for overdose, and awareness of appropriate non-clinical responses (n=52). Phase two implemented an educational intervention at two Cork addiction service sites. This involved assessing service user awareness of appropriate non-clinical methods to manage overdose and their interest in receiving resuscitation training (n=26). Phase three piloted a resuscitation skills training intervention for staff, family and IDU consisting of instruction on how to recognise and prevent overdose, appropriate response techniques; rescue breathing, and calling emergency services (n=26). Results. The findings illustrated the majority had experienced overdose, described the main substances involved, the settings, the responses employed, and the perceptions of risk. The need for education equipping IDU with overdose prevention and management skills was identified. Awareness of appropriate responses (correct emergency numbers, recovery and resuscitation skills) improved following the educational and skills training interventions Conclusions. Continued efforts in Ireland to integrate culturally specific overdose prevention into agonist opioid treatment services, prison discharge, homeless primary health and needle and syringe exchange are warranted

    Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.

    Get PDF
    Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters

    Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.

    Get PDF
    Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters

    Failure of a non-authorized copy product to maintain response achieved with imatinib in a patient with chronic phase chronic myeloid leukemia: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Due to high rates of response and durable remissions, imatinib (Glivec<sup>®</sup>, or Gleevec<sup>®</sup> in the USA; Novartis Pharma AG) is the standard of care in patients with chronic myeloid leukemia. Recently, a non-authorized product which claims comparability to imatinib has become available.</p> <p>Case presentation</p> <p>This report describes the loss of response in a 36-year-old male patient with chronic-phase chronic myeloid leukemia who had previously been in full hematologic and cytogenetic remission and partial molecular remission for three years, under treatment with brand-name imatinib of 400 mg per day. Before the initiation of treatment with a copy product, imatib (CIPLA-India), the patient had negative BCR-ABL status. Within three months of initiation of treatment with the copy product, the patient's BCR-ABL status became positive, with substantial decreases noted in white blood cell counts, red blood cell counts and platelet counts. Conversion of the BCR-ABL status to negative and improvements in hematologic parameters were achieved when the brand medication, imatinib, was resumed at a dose of 600 mg per day.</p> <p>Conclusion</p> <p>In our patient, the substitution of a copy product for imatinib resulted in the rapid loss of a previously stable response, with the risk of progression to life-threatening accelerated phase or blast crisis phase of the disease. Without supportive clinical evidence of efficacy and safety of imatib (or any other copy product) caution should be used when substituting imatinib in the treatment of any patient with chronic myeloid leukemia.</p

    Genomic insights into the population history and adaptive traits of Latin American Criollo cattle.

    Get PDF
    Criollo cattle, the descendants of animals brought by Iberian colonists to the Americas, have been the subject of natural and human-mediated selection in novel tropical agroecological zones for centuries. Consequently, these breeds have evolved distinct characteristics such as resistance to diseases and exceptional heat tolerance. In addition to European taurine (Bos taurus) ancestry, it has been proposed that gene flow from African taurine and Asian indicine (Bos indicus) cattle has shaped the ancestry of Criollo cattle. In this study, we analysed Criollo breeds from Colombia and Venezuela using whole-genome sequencing (WGS) and single-nucleotide polymorphism (SNP) array data to examine population structure and admixture at high resolution. Analysis of genetic structure and ancestry components provided evidence for African taurine and Asian indicine admixture in Criollo cattle. In addition, using WGS data, we detected selection signatures associated with a myriad of adaptive traits, revealing genes linked to thermotolerance, reproduction, fertility, immunity and distinct coat and skin coloration traits. This study underscores the remarkable adaptability of Criollo cattle and highlights the genetic richness and potential of these breeds in the face of climate change, habitat flux and disease challenges. Further research is warranted to leverage these findings for more effective and sustainable cattle breeding programmes

    Regeneration of the Semitendinosus Tendon Harvested for Anterior Cruciate Ligament Reconstruction. Evaluation Using Ultrasonography

    Get PDF
    In a prospective study, 40 consecutive patients who underwent anterior cruciate ligament reconstruction with doubled semitendinosus and gracilis tendon autografts were examined pre- and postoperatively by ultrasound to investigate the anatomy of the donor site before and after the harvest of the tendons. The patients underwent ultrasonography at 2 weeks and 1, 2, 3, 6, 12, 18, and 24 months postoperatively. A total of 298 postoperative sonographic evaluations were performed. The semitendinosus tendon was imaged in the sagittal and axial planes: structure and margins were evaluated with the sagittal views; thickness and width were measured with the axial views. In all cases the following sequence of healing was documented: 2 weeks after surgery the semitendinosus tendon site was occupied by an area of increased thickness and decreased echogenicity, suggesting the presence of traumatic edema of the soft tissue surrounding the tenotomy. At 1 month, an irregular hypoechoic structure appeared in a near-anatomic position; at 2 months after surgery, thickness, width, and cross-sectional area of this structure were significantly greater than preoperatively. The amount of regenerated tissue increased up to that seen in the tissue of the 6-month examinations, which also showed a more uniform echostructure. The scans performed at 1 year showed distinct edges and reduction in thickness and width. At 18 and 24 months the echogenicity of the structure occupying the donor site was very similar to that of the normal semitendinosus tendon. However, this structure was clearly identified about 4 cm proximal to the pes anserinus, revealing a more proximal insertion of the regenerated semitendinosus tendon

    Favorable patient acceptance of ambulatory blood pressure monitoring in a primary care setting in the United States: a cross-sectional survey

    Get PDF
    BACKGROUND: The use of ambulatory blood pressure monitoring (ABPM) in the diagnosis and management of hypertension in primary care settings in the United States is increasing. Insufficient information is available describing patients' experiences and acceptance of this technology in the United States, where medical insurance coverage of the procedure is often limited. The objective of this study was to describe patient satisfaction with ABPM performed in a primary care office in the United States, using modern ABPM technology. METHODS: Cross-sectional survey performed on consecutive patients referred to the ABPM service of the Family Care Center, University of Iowa Hospitals and Clinics, Iowa City, Iowa from January 2001 to July 2003. Measures of patient satisfaction and acceptance with the device, comfort, and overall session were assessed via a 9-question, Likert-scale response survey. RESULTS: Since its inception two and a half years ago, 245 total ABPM sessions have been conducted in 235 unique patients. Of the 235 eligible respondents, 177 returned completed surveys, yielding a 75% response rate. Three-fourths (75%) of patients believed that undergoing the test was worthwhile considering the time and monetary cost involved, while most (90%) reported they thought the information provided by the test would be helpful to their physician in making treatment decisions. Patients reporting that their physician had clearly explained the benefit of undergoing the testing were more likely to report that they thought the results of the test would be more helpful in making treatment decisions. Few patients (20%) found that wearing the monitor was uncomfortable. CONCLUSIONS: When clinically indicated, clinicians should not hesitate to order ABPM testing for fear of subjecting patients to an uncomfortable test, or an uncovered insurance benefit. When ordering ABPM, they should be sure to educate the patient about the potential benefits of undergoing the testing. Most patients believe the test will provide useful information in making treatment decisions, despite probable lack of insurance coverage, and appear willing to experience some discomfort for the overall gain of the results obtained from undergoing the session

    An international internet survey of the experiences of 1,714 mothers with a late stillbirth: The STARS cohort study

    Get PDF
    Background: Stillbirth occurring after 28 weeks gestation affects between 1.5-4.5 per 1,000 births in high-income countries. The majority of stillbirths in this setting occur in women without risk factors. In addition, many established risk factors such as nulliparity and maternal age are not amenable to modification during pregnancy. Identification of other risk factors which could be amenable to change in pregnancy should be a priority in stillbirth prevention research. Therefore, this study aimed to utilise an online survey asking women who had a stillbirth about their pregnancy in order to identify any common symptoms and experiences. Methods: A web-based survey. Results: A total of 1,714 women who had experienced a stillbirth >3 weeks prior to enrolment completed the survey. Common experiences identified were: perception of changes in fetal movement (63 % of respondents), reports of a "gut instinct" that something was wrong (68 %), and perceived time of death occurring overnight (56 %). A quarter of participants believed that their baby's death was due to a cord issue and another 18 % indicated that they did not know the reason why their baby died. In many cases (55 %) the mother believed the cause of death was different to that told by clinicians. Conclusions: This study confirms the association between altered fetal movements and stillbirth and highlights novel associations that merit closer scrutiny including a maternal gut instinct that something was wrong. The potential importance of maternal sleep is highlighted by the finding of more than half the mothers believing their baby died during the night. This study supports the importance of listening to mothers' concerns and symptoms during pregnancy and highlights the need for thorough investigation of stillbirth and appropriate explanation being given to parents
    corecore