1,045 research outputs found

    Flow of Binary and Tertiary Mixtures of Waxes

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66517/2/10.1177_00220345660450023101.pd

    Evaluation of black carbon estimations in global aerosol models

    Get PDF
    We evaluate black carbon (BC) model predictions from the AeroCom model intercomparison project by considering the diversity among year 2000 model simulations and comparing model predictions with available measurements. These model-measurement intercomparisons include BC surface and aircraft concentrations, aerosol absorption optical depth (AAOD) retrievals from AERONET and Ozone Monitoring Instrument (OMI) and BC column estimations based on AERONET. In regions other than Asia, most models are biased high compared to surface concentration measurements. However compared with (column) AAOD or BC burden retreivals, the models are generally biased low. The average ratio of model to retrieved AAOD is less than 0.7 in South American and 0.6 in African biomass burning regions; both of these regions lack surface concentration measurements. In Asia the average model to observed ratio is 0.7 for AAOD and 0.5 for BC surface concentrations. Compared with aircraft measurements over the Americas at latitudes between 0 and 50N, the average model is a factor of 8 larger than observed, and most models exceed the measured BC standard deviation in the mid to upper troposphere. At higher latitudes the average model to aircraft BC ratio is 0.4 and models underestimate the observed BC loading in the lower and middle troposphere associated with springtime Arctic haze. Low model bias for AAOD but overestimation of surface and upper atmospheric BC concentrations at lower latitudes suggests that most models are underestimating BC absorption and should improve estimates for refractive index, particle size, and optical effects of BC coating. Retrieval uncertainties and/or differences with model diagnostic treatment may also contribute to the model-measurement disparity. Largest AeroCom model diversity occurred in northern Eurasia and the remote Arctic, regions influenced by anthropogenic sources. Changing emissions, aging, removal, or optical properties within a single model generated a smaller change in model predictions than the range represented by the full set of AeroCom models. Upper tropospheric concentrations of BC mass from the aircraft measurements are suggested to provide a unique new benchmark to test scavenging and vertical dispersion of BC in global models

    Readiness to adopt a performance measurement system for substance abuse treatment: Findings from the Service Quality Measures initiative

    Get PDF
    Background. A performance measurement system – the Service Quality Measures (SQM) initiative – has been developed to monitor the quality of South Africa (SA)’s substance abuse treatment services. Identifying factors associated with readiness to adopt this system may inform strategies to facilitate its robust implementation.Objective. To examine factors associated with readiness to adopt a performance measurement system among SA substance abuse treatment providers.Methods. We surveyed 81 treatment providers from 13 treatment sites in the Western Cape, SA. The survey examined awareness, resources, organisational climate, leadership support and readiness to adopt the SQM system. Regression analysis was used to identify factors associated with readiness to adopt this system.Results. Readiness to adopt the SQM initiative was high (M=5.64, standard deviation 1.63). In bivariate analyses, caseload size (F=3.73 (degrees of freedom (df)=3.70), p=0.015), awareness (r=0.78, p<0.0001), leadership support (r=0.70, p<0.0001), resources (r=0.65, p<0.0001), openness to change (r=0.372, p=0.001), and external pressure to change were associated with readiness to adopt the SQM. In multivariate analyses, only awareness of the SQM initiative (B=0.34, standard error (SE) 0.08, t=4.4, p<0.0001) and leadership support (B=0.45, SE 0.11, t=4.0, p<0.0001) were significantly associated with readiness to adopt this system.Conclusion. While treatment providers report high levels of readiness to adopt the SQM system, findings show that the likelihood of adoption can be further increased through improved provider awareness and enhanced leadership support for this health innovation

    Pattern matching and pattern discovery algorithms for protein topologies

    Get PDF
    We describe algorithms for pattern matching and pattern learning in TOPS diagrams (formal descriptions of protein topologies). These problems can be reduced to checking for subgraph isomorphism and finding maximal common subgraphs in a restricted class of ordered graphs. We have developed a subgraph isomorphism algorithm for ordered graphs, which performs well on the given set of data. The maximal common subgraph problem then is solved by repeated subgraph extension and checking for isomorphisms. Despite the apparent inefficiency such approach gives an algorithm with time complexity proportional to the number of graphs in the input set and is still practical on the given set of data. As a result we obtain fast methods which can be used for building a database of protein topological motifs, and for the comparison of a given protein of known secondary structure against a motif database

    Ground-state properties of tubelike flexible polymers

    Full text link
    In this work we investigate structural properties of native states of a simple model for short flexible homopolymers, where the steric influence of monomeric side chains is effectively introduced by a thickness constraint. This geometric constraint is implemented through the concept of the global radius of curvature and affects the conformational topology of ground-state structures. A systematic analysis allows for a thickness-dependent classification of the dominant ground-state topologies. It turns out that helical structures, strands, rings, and coils are natural, intrinsic geometries of such tubelike objects

    Which patients benefit from model-informed precision dosing of beta-lactam antibiotics and ciprofloxacin at the ICU?

    Get PDF
    Objectives: Antibiotic dosing is not optimal in the ICU. Our recent trial investigated the effect of model-informed precision dosing (MIPD) of beta-lactam antibiotics and ciprofloxacin and showed no significant differences in clinical outcomes in all patients. This study aimed to identify subgroups of patients in which the MIPD of these antibiotics could be beneficial for clinical outcomes. Methods: We analysed data from the DOLPHIN randomized controlled trial, which compared MIPD to standard dosing of beta-lactam antibiotics and ciprofloxacin in 388 ICU patients. We divided patients into subgroups based on baseline characteristics and assessed the effect of MIPD on 28-day mortality, 6-month mortality, change in sequential organ failure assessment (delta-SOFA), and ICU length of stay (LOS). Results: We found a lower 28-day mortality in patients with a SOFA below 8 randomized to MIPD (OR 0.40; 95% CI 0.17–0.88). However, patients with a higher SOFA show an increased 28-day mortality (OR 1.94; 95% CI 1.07–3.59) in the MIPD group. ICU LOS was increased in patients receiving MIPD with a SOFA below 8 (IRR 1.36; 95% CI 1.01–1.83) and those receiving MIPD for ceftriaxone (IRR 1.76; 95% CI 1.24–2.51). Patients receiving a dose recommendation within 24 hours show a trend towards decreased ICU LOS (IRR 0.77; 95% CI 0.52–1.16) and higher delta-SOFA (estimate -1.19; 95% CI -2.98–0.60). Conclusions: ICU patients with a SOFA below 8 using MIPD had an increased ICU LOS but a lower 28-day mortality. Fast dose recommendations using MIPD of beta-lactam antibiotics and ciprofloxacin needs to be investigated in ICU patients.</p

    Pursuing the Real Vancomycin Clearance during Continuous Renal Replacement Therapy in Intensive Care Unit Patients:Is There Adequate Target Attainment?

    Get PDF
    Introduction: Vancomycin is used in intensive care unit (ICU) patients for the treatment of infections caused by gram-positive bacteria. The vancomycin pharmacokinetic/pharmacodynamic index is a ratio of the area under the concentration to the minimum inhibitory concentration ≥400-600 h∗mg/L. This target can generally be achieved by a plasma concentration of 20-25 mg/L. Together with the pathophysiological alterations and pharmacokinetic variability associated with critical illness, the use of continuous renal replacement therapy (CRRT) may complicate the attainment of adequate vancomycin concentrations. The primary objective was the prevalence of attainment of vancomycin concentrations 20-25 mg/L after 24 h in adult ICU patients receiving CRRT. Secondary outcomes were to evaluate target attainment at days 2 and 3 and to calculate vancomycin clearance (CL) by CRRT and residual diuresis. Methods: We performed a prospective observational study in adult ICU patients on CRRT, which received at least 24 h continuous infusion of vancomycin. Between May 2020 and February 2021, daily vancomycin residual blood gas and dialysate samples were collected from 20 patients, every 6 h and if possible vancomycin urine samples. Vancomycin was analysed with an immunoassay method. The CL by CRRT was calculated by a different approach correcting for the downtime and providing insight into the degree of filter patency. Results: The proportion of patients with vancomycin concentrations &lt;20 mg/L was 50% 24 h after starting vancomycin (n = 10). No differences were observed in patient characteristics. The target vancomycin concentration 20-25 mg/L was only achieved in 30% of the patients. On days 2 and 3, despite the use of TDM and albeit in lower percentages, sub- and supratherapeutic levels were still observed. Taking downtime and filter patency into account resulted in lower vancomycin CL. Conclusions: 50% of the studied ICU patients on CRRT showed subtherapeutic vancomycin concentrations 24 h after starting therapy. The results reveal that optimization of vancomycin dosage during CRRT therapy is needed.</p

    Low Energy Analyzing Powers in Pion-Proton Elastic Scattering

    Full text link
    Analyzing powers of pion-proton elastic scattering have been measured at PSI with the Low Energy Pion Spectrometer LEPS as well as a novel polarized scintillator target. Angular distributions between 40 and 120 deg (c.m.) were taken at 45.2, 51.2, 57.2, 68.5, 77.2, and 87.2 MeV incoming pion kinetic energy for pi+ p scattering, and at 67.3 and 87.2 MeV for pi- p scattering. These new measurements constitute a substantial extension of the polarization data base at low energies. Predictions from phase shift analyses are compared with the experimental results, and deviations are observed at low energies.Comment: 15 pages, 4 figure

    On the pion-nucleon coupling constant

    Full text link
    In view of persisting misunderstanding about the determination of the pion-nucleon coupling constants in the Nijmegen multienergy partial-wave analyses of pp, np, and pbar-p scattering data, we present additional information which may clarify several points of discussion. We comment on several recent papers addressing the issue of the pion-nucleon coupling constant and criticizing the Nijmegen analyses.Comment: 19 pages, Nijmegen preprint THEF-NYM-92-0
    corecore