44 research outputs found

    Higher socioeconomic status is related to healthier levels of fatness and fitness already at 3 to 5 years of age: The PREFIT project: Relation between socioeconomic status, fatness and fitness in preschoolers

    Get PDF
    This study aimed to analyse the association between socioeconomic status (SES) and fatness and fitness in preschoolers. 2, 638 preschoolers (3–5 years old; 47.2% girls) participated. SES was estimated from the parental educational and occupational levels, and the marital status. Fatness was assessed by body mass index (BMI), waist circumference (WC), and waist-to-height ratio (WHtR). Physical fitness components were assessed using the PREFIT battery. Preschoolers whose parents had higher educational levels had lower fatness (P < 0.05). BMI significantly differed across occupational levels of each parent (P < 0.05) and WHtR across paternal levels (P = 0.004). Musculoskeletal fitness was different across any SES factor (P < 0.05), except handgrip across paternal occupational levels (P = 0.05). Preschoolers with high paternal occupation had higher speed/agility (P = 0.005), and those with high or low maternal education had higher VO2max (P = 0.046). Odds of being obese and having low musculoskeletal fitness was lower as SES was higher (P < 0.05). Those with married parents had higher cardiorespiratory fitness than single-parent ones (P = 0.010). School-based interventions should be aware of that children with low SES are at a higher risk of obesity and low fitness already in the first years of life

    Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

    Full text link
    [EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. Finally, we thank Brendon Bullard, Paolo Giromini and Neeraj Tata for helpful discussions and assistance with preliminary measurements.Ghosh, S.; Haefner, J.; Martín-Albo, J.; Guenette, R.; Li, X.; Loya Villalpando, A.; Burch, C.... (2020). Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air. Journal of Instrumentation. 15(11):1-17. https://doi.org/10.1088/1748-0221/15/11/P11031S1171511Auger, M., Auty, D. J., Barbeau, P. S., Bartoszek, L., Baussan, E., Beauchamp, E., … Cleveland, B. (2012). The EXO-200 detector, part I: detector design and construction. Journal of Instrumentation, 7(05), P05010-P05010. doi:10.1088/1748-0221/7/05/p05010Martín-Albo, J., Muñoz Vidal, J., Ferrario, P., Nebot-Guinot, M., Gómez-Cadenas, J. J., … Cárcel, S. (2016). Sensitivity of NEXT-100 to neutrinoless double beta decay. Journal of High Energy Physics, 2016(5). doi:10.1007/jhep05(2016)159Rogers, L., Clark, R. A., Jones, B. J. P., McDonald, A. D., Nygren, D. R., Psihas, F., … Azevedo, C. D. . (2018). High voltage insulation and gas absorption of polymers in high pressure argon and xenon gases. Journal of Instrumentation, 13(10), P10002-P10002. doi:10.1088/1748-0221/13/10/p10002Silva, C., Pinto da Cunha, J., Pereira, A., Chepel, V., Lopes, M. I., Solovov, V., & Neves, F. (2010). Reflectance of polytetrafluoroethylene for xenon scintillation light. Journal of Applied Physics, 107(6), 064902. doi:10.1063/1.3318681Haefner, J., Neff, A., Arthurs, M., Batista, E., Morton, D., Okunawo, M., … Lorenzon, W. (2017). Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 856, 86-91. doi:10.1016/j.nima.2017.01.057Kravitz, S., Smith, R. J., Hagaman, L., Bernard, E. P., McKinsey, D. N., Rudd, L., … Sakai, M. (2020). Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX. The European Physical Journal C, 80(3). doi:10.1140/epjc/s10052-020-7800-6Geis, C., Grignon, C., Oberlack, U., García, D. R., & Weitzel, Q. (2017). Optical response of highly reflective film used in the water Cherenkov muon veto of the XENON1T dark matter experiment. Journal of Instrumentation, 12(06), P06017-P06017. doi:10.1088/1748-0221/12/06/p06017Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., … Barrand, G. (2016). Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 835, 186-225. doi:10.1016/j.nima.2016.06.12

    Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector

    Full text link
    [EN] New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.This work was supported by the European Research Council under grant ID 757829 and by Ministerio de Economia y Competitividad for grant FPA2016-78595-C3-1-R.Renner, J.; Romo-Luque, C.; Aliaga, RJ.; Álvarez-Puerta, V.; Ballester Merelo, FJ.; Benlloch-Rodríguez, J.; Carrión, J.... (2022). Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector. Journal of Instrumentation. 17(5):1-14. https://doi.org/10.1088/1748-0221/17/05/P0504411417

    Development and Validation of Hepamet Fibrosis Scoring System-a Simple, Non-invasive Test to Identify Patients With Nonalcoholic Fatty liver Disease With Advanced Fibrosis

    Get PDF
    BACKGROUND & AIMS: Fibrosis affects prognoses for patients with nonalcoholic fatty liver disease (NAFLD). Several non-invasive scoring systems have aimed to identify patients at risk for advanced fibrosis, but inconclusive results and variations in features of patients (diabetes, obesity and older age) reduce their diagnostic accuracy. We sought to develop a scoring system based on serum markers to identify patients with NAFLD at risk for advanced fibrosis. METHODS: We collected data from 2452 patients with NAFLD at medical centers in Italy, France, Cuba, and China. We developed the Hepamet fibrosis scoring system using demographic, anthropometric, and laboratory test data, collected at time of liver biopsy, from a training cohort of patients from Spain (n=768) and validated the system using patients from Cuba (n=344), Italy (n=288), France (n=830), and China (n=232). Hepamet fibrosis score (HFS) were compared with those of previously developed fibrosis scoring systems (the NAFLD fibrosis score [NFS] and FIB-4). The diagnostic accuracy of the Hepamet fibrosis scoring system was assessed based on area under the receiver operating characteristic (AUROC) curve, sensitivity, specificity, diagnostic odds ratio, and positive and negative predictive values and likelihood ratios. RESULTS: Variables used to determine HFS were patient sex, age, homeostatic model assessment score, presence of diabetes, levels of aspartate aminotransferase, and albumin, and platelet counts; these were independently associated with advanced fibrosis. HFS discriminated between patients with and without advanced fibrosis with an AUROC curve value of 0.85 whereas NFS or FIB-4 did so with AUROC values of 0.80 (P=.0001). In the validation set, cut-off HFS of 0.12 and 0.47 identified patients with and without advanced fibrosis with 97.2% specificity, 74% sensitivity, a 92% negative predictive value, a 76.3% positive predictive value, a 13.22 positive likelihood ratio, and a 0.31 negative likelihood ratio. HFS were not affected by patient age, body mass index, hypertransaminasemia, or diabetes. The Hepamet fibrosis scoring system had the greatest net benefit in identifying patients who should undergo liver biopsy analysis and led to significant improvements in reclassification, reducing the number of patients with undetermined results to 20% from 30% for the FIB-4 and NFS systems (P<.05). CONCLUSIONS: Using clinical and laboratory data from patients with NAFLD, we developed and validated the Hepamet fibrosis scoring system, which identified patients with advanced fibrosis with greater accuracy than the FIB-4 and NFS systems. the Hepamet system provides a greater net benefit for the decision-making process to identify patients who should undergo liver biopsy analysis

    Eliminación de la hepatitis C. Documento de posicionamiento de la Asociación Española para el Estudio del Hígado (AEEH)

    Get PDF
    La Asociación Española para el Estudio del Hígado (AEEH) está convencida de que la eliminación de la hepatitis C en España es posible siempre y cuando seamos capaces de emplear los recursos y las herramientas necesarias para la misma. Este documento refleja la posición de la AEEH respecto a la eliminación del virus de la hepatitis C (VHC), estableciendo una amplia serie de recomendaciones que se pueden agrupar en cinco categorías: 1) cribado del VHC en función de la edad, de la existencia de factores de riesgo clásicos de adquisición de la infección, búsqueda activa de pacientes diagnosticados con anterioridad y desarrollo de estrategias de microeliminación en poblaciones vulnerables; 2) simplificación del diagnóstico del VHC (diagnóstico en un solo paso y diagnóstico en el punto de atención del paciente); 3) simplificación del tratamiento de los pacientes y mejora de los circuitos asistenciales; 4) medidas de política sanitaria, y, finalmente, 5) establecimiento de indicadores de eliminación del VHC. The Spanish Association for the Study of the Liver (AEEH) is convinced that the elimination of hepatitis C virus (HCV) in Spain is possible as long as we are able to use the resources and tools necessary for it. This document reflects the position of the AEEH regarding the elimination of HCV, establishing a wide range of recommendations that can be grouped into five categories: 1) Screening of HCV according to age, of the existence of classic acquisition risk factors of infection, active search of previously diagnosed patients and development of microelimination strategies in vulnerable populations; 2) Simplification of HCV diagnosis (one-step diagnosis and diagnosis at the point of patient care); 3) Simplification of patient treatment and improvement of care circuits; 4) Health policy measures, and, finally, 5) Establishment of HCV elimination indicators

    Evolution of the use of corticosteroids for the treatment of hospitalised COVID-19 patients in Spain between March and November 2020: SEMI-COVID national registry

    Get PDF
    Objectives: Since the results of the RECOVERY trial, WHO recommendations about the use of corticosteroids (CTs) in COVID-19 have changed. The aim of the study is to analyse the evolutive use of CTs in Spain during the pandemic to assess the potential influence of new recommendations. Material and methods: A retrospective, descriptive, and observational study was conducted on adults hospitalised due to COVID-19 in Spain who were included in the SEMI-COVID- 19 Registry from March to November 2020. Results: CTs were used in 6053 (36.21%) of the included patients. The patients were older (mean (SD)) (69.6 (14.6) vs. 66.0 (16.8) years; p < 0.001), with hypertension (57.0% vs. 47.7%; p < 0.001), obesity (26.4% vs. 19.3%; p < 0.0001), and multimorbidity prevalence (20.6% vs. 16.1%; p < 0.001). These patients had higher values (mean (95% CI)) of C-reactive protein (CRP) (86 (32.7-160) vs. 49.3 (16-109) mg/dL; p < 0.001), ferritin (791 (393-1534) vs. 470 (236- 996) µg/dL; p < 0.001), D dimer (750 (430-1400) vs. 617 (345-1180) µg/dL; p < 0.001), and lower Sp02/Fi02 (266 (91.1) vs. 301 (101); p < 0.001). Since June 2020, there was an increment in the use of CTs (March vs. September; p < 0.001). Overall, 20% did not receive steroids, and 40% received less than 200 mg accumulated prednisone equivalent dose (APED). Severe patients are treated with higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%. Conclusions: Patients with greater comorbidity, severity, and inflammatory markers were those treated with CTs. In severe patients, there is a trend towards the use of higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%

    A Compact Dication Source for Ba2+^{2+} Tagging and Heavy Metal Ion Sensor Development

    Full text link
    We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba2+\mathrm{Ba^{2+}} ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb2+^{2+} and Cd2+^{2+} also demonstrated for this purpose
    corecore