381 research outputs found

    Polymer-Grafted Mesoporous Silica Nanoparticles as Ultrasound-Responsive Drug Carriers

    Get PDF
    A new ultrasound-responsive system based on mesoporous silica nanoparticles was developed for biomedical applications, grafting a copolymer on their surface that acts as gatekeeper of the pores. The nanoparticles can be loaded with a cargo at low temperature (4 degrees C), taking advantage of the open conformation that the polymer presents under these conditions. Then, at 37 degrees C the copolymer collapses closing the pore entrances and allowing the nanoparticles to carry the drugs at physiological temperature without premature release, which is of great importance when dealing with cytotoxic drugs in cancer treatments. Upon ultrasound irradiation, the sensitive polymer changes its hydrophobicity and, therefore, its conformation toward coil-like opening the gates and releasing the cargo. These hybrid nanoparticles have been shown to be noncytotoxic and can be internalized into LNCaP cells retaining their ultrasound-responsive capability in the cytoplasm of the cells. Moreover, doxorubicin-loaded hybrid MSNs were incubated with LNCaP cells to show their capacity to induce cell death only when the nanoparticles had been exposed to ultrasound. This work demonstrates that our hybrid-MSNs can be triggered by remote stimuli, which is of capital importance for future applications in drug delivery and cancer therapy

    Tuning mesoporous silica dissolution in physiological environments: a review

    Get PDF
    Matrix degradation has a major impact on the release kinetics of drug delivery systems. Regarding ordered mesoporous silica materials for biomedical applications, their dissolution is an important parameter that should be taken into consideration. In this paper, we review the main factors that govern the mesoporous silica dissolution in physiological environments. We also provide the necessary knowledge to researchers in the area for tuning the dissolution rate of those matrices, so the degradation could be controlled and the material behaviour optimised

    Vectorization of ultrasound-responsive nanoparticles in placental mesenchymal stem cells for cancer therapy

    Get PDF
    A new platform constituted by engineered responsive nanoparticles transported by human mesenchymal stem cells is here presented as a proof of concept. Ultrasound-responsive mesoporous silica nanoparticles are coated with polyethylenimine to favor their effective uptake by decidua-derived mesenchymal stem cells. The responsive-release ability of the designed nanoparticles is confirmed, both in vial and in vivo. In addition, this capability is maintained inside the cells used as carriers. The migration capacity of the nanoparticle-cell platform towards mammary tumors is assessed in vitro. The efficacy of this platform for anticancer therapy is shown against mammary tumor cells by inducing the release of doxorubicin only when the cell vehicles are exposed to ultrasound

    Atomistic simulations of geopolymer models: the impact of disorder on structure and mechanics

    Get PDF
    Geopolymers are hydrated aluminosilicates with excellent binding properties. Geopolymers appeal to the construction sector as a more sustainable alternative to traditional cements, but their exploitation is limited by a poor understanding of the linkage between chemical composition and macroscopic properties. Molecular simulations can help clarify this linkage, but existing models based on amorphous or crystalline aluminosilicate structures provide only a partial explanation of experimental data on the nanoscale. This paper presents a new model for the molecular structure of geopolymers, in particular for nanoscale interfacial zones between crystalline and amorphous nanodomains, which are crucial for the overall mechanical properties of the material. For a range of Si–Al molar ratios and water contents, the proposed structures are analyzed in terms of skeletal density, ring structure, pore structure, bond-angle distribution, bond length distribution, X-ray diffraction, X-ray pair distribution function, elastic moduli, and large-strain mechanics. Results are compared with experimental data and with other simulation results for amorphous and crystalline molecular models, showing that the newly proposed structures better capture important structural features with an impact on mechanical properties. This offers a new starting point for the multiscale modeling of geopolymers

    Mesoporous Silica Nanoparticles Engineered for Ultrasound-Induced Uptake by Cancer Cells

    Get PDF
    A novel smart hierarchical ultrasound-responsive mesoporous silica nanocarrier for cancer therapy is here presented. This dynamic nanosystem has been designed to display different surface characteristics during its journey towards tumor cells. Initially, the anticancer-loaded nanocarriers are shielded with a polyethylene glycol layer. Upon exposure to high frequency ultrasound, the polymer shell detaches from the nanoparticles, exposing a positively-charged surface. That favors the internalization in human osteosarcoma cells, where release of topotecan takes place, drastically enhancing the cytotoxic effect

    From Proof-of-Concept Material to PEGylated and Modularly Targeted Ultrasound-Responsive Mesoporous Silica Nanoparticles

    Get PDF
    In this work we present the synthesis, characterization and in vitro biological evaluation of PEGylated and actively-targeted ultrasound-responsive hybrid mesoporous silica nanoparticles. This work covers the development of the chemical strategies necessary to afford a modular nanocarrier starting from a proof-of-concept material presented in previous work. This functional ultrasound-responsive material can be adapted to different specific pathological conditions by carefully choosing the appropriate targeting moieties. The new ultrasound responsive material is able to target HeLa cells when conjugated with biotin or an RGD peptide. Ultrasound-responsive cytotoxicity towards cancer cells of doxorubicinloaded nanoparticles is demonstrated in an in vitro cytotoxicity assay

    Parabolic stable surfaces with constant mean curvature

    Full text link
    We prove that if u is a bounded smooth function in the kernel of a nonnegative Schrodinger operator L=(Δ+q)-L=-(\Delta +q) on a parabolic Riemannian manifold M, then u is either identically zero or it has no zeros on M, and the linear space of such functions is 1-dimensional. We obtain consequences for orientable, complete stable surfaces with constant mean curvature HRH\in\mathbb{R} in homogeneous spaces E(κ,τ)\mathbb{E}(\kappa,\tau) with four dimensional isometry group. For instance, if M is an orientable, parabolic, complete immersed surface with constant mean curvature H in H2×R\mathbb{H}^2\times\mathbb{R}, then H1/2|H|\leq 1/2 and if equality holds, then M is either an entire graph or a vertical horocylinder.Comment: 15 pages, 1 figure. Minor changes have been incorporated (exchange finite capacity by parabolicity, and simplify the proof of Theorem 1)

    Diastolic shock index and clinical outcomes in patients with septic shock

    Get PDF
    Background: Loss of vascular tone is a key pathophysiological feature of septic shock. Combination of gradual diastolic hypotension and tachycardia could reflect more serious vasodilatory conditions. We sought to evaluate the relationships between heart rate (HR) to diastolic arterial pressure (DAP) ratios and clinical outcomes during early phases of septic shock. Methods: Diastolic shock index (DSI) was defined as the ratio between HR and DAP. DSI calculated just before starting vasopressors (Pre-VPs/DSI) in a preliminary cohort of 337 patients with septic shock (January 2015 to February 2017) and at vasopressor start (VPs/DSI) in 424 patients with septic shock included in a recent randomized controlled trial (ANDROMEDA-SHOCK; March 2017 to April 2018) was partitioned into five quantiles to estimate the relative risks (RR) of death with respect to the mean risk of each population (assumed to be 1). Matched HR and DAP subsamples were created to evaluate the effect of the individual components of the DSI on RRs. In addition, time-course of DSI and interaction between DSI and vasopressor dose (DSI*NE.dose) were compared between survivors and non-survivors from both populations, while ROC curves were used to identify variables predicting mortality. Finally, as exploratory observation, effect of early start of vasopressors was evaluated at each Pre-VPs/DSI quintile from the preliminary cohort. Results: Risk of death progressively increased at gradual increments of Pre-VPs/DSI or VPs/DSI (One-way ANOVA, p < 0.001). Progressive DAP decrease or HR increase was associated with higher mortality risks only when DSI concomitantly increased. Areas under the ROC curve for Pre-VPs/DSI, SOFA and initial lactate were similar, while mean arterial pressure and systolic shock index showed poor performances to predict mortality. Time-course of DSI and DSI*NE.dose was significantly higher in non-survivors from both populations (repeated-measures ANOVA, p < 0.001). Very early start of vasopressors exhibited an apparent benefit at higher Pre-VPs/DSI quintile. Conclusions: DSI at pre-vasopressor and vasopressor start points might represent a very early identifier of patients at high risk of death. Isolated DAP or HR values do not clearly identify such risk. Usefulness of DSI to trigger or to direct therapeutic interventions in early resuscitation of septic shock need to be addressed in future studies

    Ultrasound-Mediated Cavitation-Enhanced Extravasation of Mesoporous Silica Nanoparticles for Controlled-Release Drug Delivery

    Get PDF
    Mesoporous silica nanoparticles have been reported as suitable drug carriers, but their successful delivery to target tissues following systemic administration remains a challenge. In the present work, ultrasound-induced inertial cavitation was evaluated as a mechanism to promote their extravasation in a flow-through tissue mimicking agarose phantom. Two different ultrasound frequencies, 0.5 or 1.6 MHz, with pressures in the range 0.5-4 MPa were used to drive cavitation activity which was detected in real time. The optimal ultrasound conditions identified were employed to deliver dye-loaded nanoparticles as a model for drug-loaded nanocarriers, with the level of extravasation evaluated by fluorescence microscopy. The same nanoparticles were then co-injected with submicrometric polymeric cavitation nuclei as a means to promote cavitation activity and decrease the required in-situ acoustic pressure required to attain extravasation. The overall cavitation energy and penetration of the combination was compared to mesoporous silica nanoparticles alone. The results of the present work suggest that combining mesoporous silica nanocarriers and submcrometric cavitation nuclei may help enhance the extravasation of the nanocarrier, thus enabling subsequent sustained drug release to happen from those particles already embedded in the tumour tissue
    corecore