1,585 research outputs found

    Blood Sampling from the Tail Vein, in Comparison with Two Other Techniques, Causes Less Stress to Mice

    Get PDF
    It is important to use the optimal method for repeated blood sampling to ensure minimal stress to mice,  and also to provide better pharmacokinetic and pharmacodynamic data. The aim of the present study was  to compare the impact of blood sampling methods on corticosterone and adrenocorticotropic hormone  (ACTH) levels in mice. Hsdwin:NMRI mice were divided into four sampling groups: control group (I), vena facialis (II), tail vein  (III) and saphenous vein (IV). The first blood samples, obtained from vena facialis, tail or saphenous vein  of conscious mice, were taken at time point 0. The second blood sample was taken by decapitation from  groups II-IV with isoflurane anaesthesia at time point 20 min. The control group animals were anesthetized  and decapitated at 20 min time point. Corticosterone levels in plasma were analyzed at time point 0 and 20  min, and ACTH at time point 20 min. Saphenous bled mice, in comparison with vena facialis and tail vein sampled mice, indicated statistically  significant greater (P < 0.05) level of corticosterone at sampling point (0 min). Rising levels of corticosterone  in all groups differed statistically (P < 0.05) from the control group level, indicating that all tested bleeding  methods were stressful to the experimental animals. However, the tail vein bleeding method stressed  statistically significantly (P < 0.05) less in comparison with vena facialis and saphenous vein bleeding.  At time point 20 min, only saphenous vein bled mice showed statistically significant greater (P < 0.05)  blood levels of ACTH compared to tail vein bled mice. Conditions in sampling and rising levels of corticosterone and/or ACTH level did not show direct correlation.  In conclusion the results suggest that the tail bleeding method accomplished least stress to mice and next  less vena facialis bleeding. Blood collection technique from the saphenous vein was the most stressful to  the experimental animals.

    Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V

    Full text link
    The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and 46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8), 6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are substantially improved in precision over previous results.Comment: 9 pages, 7 figures, 5 table

    Laser Spectroscopy of Niobium Fission Fragments: First Use of Optical Pumping in an Ion Beam Cooler Buncher

    Get PDF
    A new method of optical pumping in an ion beam cooler buncher has been developed to selectively enhance ionic metastable state populations. The technique permits the study of elements previously inaccessible to laser spectroscopy and has been applied here to the study of Nb. Model independent mean-square charge radii and nuclear moments have been studied for 90,90m,91,91m,92,93,99,101,103^{90,90 m,91,91 m,92,93,99,101,103}Nb to cover the region of the N=50 shell closure and N≈60 sudden onset of deformation. The increase in mean-square charge radius is observed to be less than that for Y, with a substantial degree of β softness observed before and after N=60

    Dialogue based interfaces for universal access.

    Get PDF
    Conversation provides an excellent means of communication for almost all people. Consequently, a conversational interface is an excellent mechanism for allowing people to interact with systems. Conversational systems are an active research area, but a wide range of systems can be developed with current technology. More sophisticated interfaces can take considerable effort, but simple interfaces can be developed quite rapidly. This paper gives an introduction to the current state of the art of conversational systems and interfaces. It describes a methodology for developing conversational interfaces and gives an example of an interface for a state benefits web site. The paper discusses how this interface could improve access for a wide range of people, and how further development of this interface would allow a larger range of people to use the system and give them more functionality

    Mass measurements in the vicinity of the doubly-magic waiting point 56Ni

    Full text link
    Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu, and 59Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu, Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has been obtained. Except for 53Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides which allowed also a determination of the reference masses 55Co, 58Ni, and 59Cu.Comment: 14 pages, 13 figures, submitted to Phys. Rev.

    Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the rr-process calculations

    Full text link
    The rare-earth peak in the rr-process abundance pattern depends sensitively on both the astrophysical conditions and subtle changes in nuclear structure in the region. This work takes an important step elucidating the nuclear structure and reducing the uncertainties in rr-process calculations via precise atomic mass measurements at the JYFLTRAP double Penning trap. 158^{158}Nd, 160^{160}Pm, 162^{162}Sm, and 164166^{164-166}Gd have been measured for the first time and the precisions for 156^{156}Nd, 158^{158}Pm, 162,163^{162,163}Eu, 163^{163}Gd, and 164^{164}Tb have been improved considerably. Nuclear structure has been probed via two-neutron separation energies S2nS_{2n} and neutron pairing energy metrics DnD_n. The data do not support the existence of a subshell closure at N=100N=100. Neutron pairing has been found to be weaker than predicted by theoretical mass models. The impact on the calculated rr-process abundances has been studied. Substantial changes resulting in a smoother abundance distribution and a better agreement with the solar rr-process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review Letter

    Preparation of cooled and bunched ion beams at ISOLDE-CERN

    Get PDF
    Abstract.: At ISOLDE a new RadioFrequency Quadrupole ion Cooler and Buncher (RFQCB) is being constructed to improve ion optical properties of low-energy RIBs. The new features of the mechanical design and the status of the test bench, which will serve to test the device, will be presented in this contributio

    Non-Gaussianity from Instant and Tachyonic Preheating

    Full text link
    We study non-Gaussianity in two distinct models of preheating: instant and tachyonic. In instant preheating non-Gaussianity is sourced by the local terms generated through the coupled perturbations of the two scalar fields. We find that the non-Gaussianity parameter is given by fNLϕ2g<O(1)f_{NL}^{\phi}\sim 2g < O(1), where gg is a coupling constant, so that instant preheating is unlikely to be constrained by WMAP or Planck. In the case of tachyonic preheating non-Gaussianity arises solely from the instability of the tachyon matter and is found to be large. We find that for single field inflation the present WMAP data implies a bound V01/4/MP104V_{0}^{1/4}/M_{P}\leq 10^{-4} on the scale of tachyonic instability. We argue that the tachyonic preheating limits are useful also for string-motivated inflationary models.Comment: 12 pages, 1 figure, additional discussion, improved constraint on the scale of tachyonic preheatin
    corecore