91 research outputs found

    Proactive and reactive runtime service discovery: a framework and its evaluation

    Get PDF
    The identification of services during the execution of service-based applications to replace services in them that are no longer available and/or fail to satisfy certain requirements is an important issue. In this paper we present a framework to support runtime service discovery. This framework can execute service discovery queries in pull and push mode. In pull mode, it executes queries when a need for finding a replacement service arises. In push mode, queries are subscribed to the framework to be executed proactively, and in parallel with the operation of the application, in order to identify adequate services that could be used if the need for replacing a service arises. Hence, the proactive (push) mode of query execution makes it more likely to avoid interruptions in the operation of service-based applications when a service in them needs to be replaced at runtime. In both modes of query execution, the identification of services relies on distance-based matching of structural, behavioural, quality, and contextual characteristics of services and applications. A prototype implementation of the framework has been developed and an evaluation was carried out to assess the performance of the framework. This evaluation has shown positive results, which are discussed in the paper

    Cerebellar transcranial magnetic stimulation: The role of coil type from distinct manufacturers

    Get PDF
    BACKGROUND: Stimulating the cerebellum with transcranial magnetic stimulation is often perceived as uncomfortable. No study has systematically tested which coil design can effectively trigger a cerebellar response with the least discomfort. OBJECTIVE: To determine the relationship between perceived discomfort and effectiveness of cerebellar stimulation using different coils: MagStim (70 mm, 110 mm-coated, 110-uncoated), MagVenture and Deymed. METHODS: Using the cerebellar-brain inhibition (CBI) protocol, we conducted a CBI recruitment curve with respect to each participant's maximum tolerated-stimulus intensity (MTI) to assess how effective each coil was at activating the cerebellum. RESULTS: Only the Deymed double-cone coil elicited CBI at low intensities (-20% MTI). At the MTI, the MagStim (110 mm coated/uncoated) and Deymed coils produced reliable CBI, whereas no CBI was found with the MagVenture coil. CONCLUSION: s: The Deymed double-cone coil was most effective at cerebellar stimulation at tolerable intensities. These results can guide coil selection and stimulation parameters when designing cerebellar TMS studies

    Examination of silver-graphite lithographically printed resistive strain sensors

    Get PDF
    This paper reports the design and manufacture of three differing types of resistive strain sensitive structures fabricated using the Conductive Lithographic Film (CLF) printing process. The structures, utilising two inks prepared with silver and graphite particulates as the conductive phase, have been analysed to determine electrical and mechanical properties with respect to strain, temperature and humidity when deposited on four alternative substrate materials (GlossArt, PolyArt, Teslin and Melinex)
    corecore