4,702 research outputs found

    Influence of humidity on granular packings with moving walls

    Full text link
    A significant dependence on the relative humidity H for the apparent mass (Mapp) measured at the bottom of a granular packing inside a vertical tube in relative motion is demonstrated experimentally. While the predictions of Janssen's model are verified for all values of H investigated (25%< H <80%), Mapp increases with time towards a limiting value at high relative humidities (H>60%) but remains constant at lower ones (H=25%). The corresponding Janssen length is nearly independent of the tube velocity for H>60% but decreases markedly for H=25%. Other differences are observed on the motion of individual beads in the packing. For H=25%, they are almost motionless while the mean particle fraction of the packing remains constant; for H>60% the bead motion is much more significant and the mean particle fraction decreases. The dependence of these results on the bead diameter and their interpretation in terms of the influence of capillary forces are discussed.Comment: 6 pages, 6 figure

    Granular packings with moving side walls

    Full text link
    The effects of movement of the side walls of a confined granular packing are studied by discrete element, molecular dynamics simulations. The dynamical evolution of the stress is studied as a function of wall movement both in the direction of gravity as well as opposite to it. For all wall velocities explored, the stress in the final state of the system after wall movement is fundamentally different from the original state obtained by pouring particles into the container and letting them settle under the influence of gravity. The original packing possesses a hydrostatic-like region at the top of the container which crosses over to a depth-independent stress. As the walls are moved in the direction opposite to gravity, the saturation stress first reaches a minimum value independent of the wall velocity, then increases to a steady-state value dependent on the wall-velocity. After wall movement ceases and the packing reaches equilibrium, the stress profile fits the classic Janssen form for high wall velocities, while it has some deviations for low wall velocities. The wall movement greatly increases the number of particle-wall and particle-particle forces at the Coulomb criterion. Varying the wall velocity has only small effects on the particle structure of the final packing so long as the walls travel a similar distance.Comment: 11 pages, 10 figures, some figures in colo

    Endperiodic maps via pseudo-Anosov flows

    Full text link
    We show that every atoroidal endperiodic map of an infinite-type surface can be obtained from a depth one foliation in a fibered hyperbolic 3-manifold, reversing a well-known construction of Thurston. This can be done almost-transversely to the canonical suspension flow, and as a consequence we recover the Handel-Miller laminations of such a map directly from the fibered structure. We also generalize from the finite-genus case the relation between topological entropy, growth rates of periodic points, and growth rates of intersection numbers of curves. Fixing the manifold and varying the depth one foliations, we obtain a description of the Cantwell-Conlon foliation cones and a proof that the entropy function on these cones is continuous and convex.Comment: 50 pages, 12 figure

    Optimizing dual energy cone beam CT protocols for preclinical imaging and radiation research

    Get PDF
    Objective: The aim of this work was to investigate whether quantitative dual-energy CT (DECT) imaging is feasible for small animal irradiators with an integrated cone-beam CT (CBCT) system. Methods: The optimal imaging protocols were determined by analyzing different energy combinations and dose levels. The influence of beam hardening effects and the performance of a beam hardening correction (BHC) were investigated. In addition, two systems from different manufacturers were compared in terms of errors in the extracted effective atomic numbers (Z(eff)) and relative electron densities (rho(e)) for phantom inserts with known elemental compositions and relative electron densities. Results: The optimal energy combination was determined to be 50 and 90kVp. For this combination, Z(eff) and r rho(e) can be extracted with a mean error of 0.11 and 0.010, respectively, at a dose level of 60cGy. Conclusion: Quantitative DECT imaging is feasible for small animal irradiators with an integrated CBCT system. To obtain the best results, optimizing the imaging protocols is required. Well-separated X-ray spectra and a sufficient dose level should be used to minimize the error and noise for Z(eff) and rho(e). When no BHC is applied in the image reconstruction, the size of the calibration phantom should match the size of the imaged object to limit the influence of beam hardening effects. No significant differences in Z(eff) and rho(e) errors are observed between the two systems from different manufacturers. Advances in knowledge: This is the first study that investigates quantitative DECT imaging for small animal irradiators with an integrated CBCT system

    The Influence of Group Labs on Student Adoption of Software Methodologies: An Empirical Test

    Get PDF
    The ACM\u27s CIS curriculum model calls for structured laboratories using groups to instruct students in software engineering methodologies. A social-psychological model of individual acceptance of a technological innovation is employed to empirically test the effectiveness of structured labs in fostering individual adoption of a software engineering methodology. Our findings suggest that a structured labexperience does influence a student\u27s belief system regarding the usefulness of a methodology, leading to a decision to adopt the methodology in completing individual programming assignment

    Exploring Accounting Fraud in the Subsidiary Environment

    Get PDF
    This research explores accounting fraud in the subsidiary environment. Utilizing institutional theory, we propose that the subsidiary environment provides an opportune setting and vehicle for individuals to commit accounting fraud. While a growing body of literature exists on accounting fraud, minimal work has focused on the role of the subsidiary in accounting fraud, as reported by the Securities and Exchange Commission (SEC). We sample companies for which the SEC has documented accounting fraud in their enforcement releases. We then analyze the related SEC documents to determine to what extent, if any, a subsidiary is involved in the accounting fraud. Our preliminary results provide evidence related to the industries, circumstances and types of accounting fraud that take place in a subsidiary environment. These findings provide auditors, regulators, and designers of management control systems with additional insights as to the factors surrounding fraud when companies operate in a subsidiary environment

    Chandra Measurements of a Complete Sample of X-ray Luminous Galaxy Clusters: The Luminosity-Mass Relation

    Get PDF
    We present the results of work involving a statistically complete sample of 34 galaxy clusters, in the redshift range 0.15≤\lez≤\le0.3 observed with ChandraChandra. We investigate the luminosity-mass (LMLM) relation for the cluster sample, with the masses obtained via a full hydrostatic mass analysis. We utilise a method to fully account for selection biases when modeling the LMLM relation, and find that the LMLM relation is significantly different than the relation modelled when not account for selection effects. We find that the luminosity of our clusters is 2.2±\pm0.4 times higher (when accounting for selection effects) than the average for a given mass, its mass is 30% lower than the population average for a given luminosity. Equivalently, using the LMLM relation measured from this sample without correcting for selection biases would lead to the underestimation by 40% of the average mass of a cluster with a given luminosity. Comparing the hydrostatic masses to mass estimates determined from the YXY_{X} parameter, we find that they are entirely consistent, irrespective of the dynamical state of the cluster.Comment: 31 pages, 43 figures, accepted for publication in MNRA

    Calibration of the LIGO displacement actuators via laser frequency modulation

    Full text link
    We present a frequency modulation technique for calibration of the displacement actuators of the LIGO 4-km-long interferometric gravitational-wave detectors. With the interferometer locked in a single-arm configuration, we modulate the frequency of the laser light, creating an effective length variation that we calibrate by measuring the amplitude of the frequency modulation. By simultaneously driving the voice coil actuators that control the length of the arm cavity, we calibrate the voice coil actuation coefficient with an estimated 1-sigma uncertainty of less than one percent. This technique enables a force-free, single-step actuator calibration using a displacement fiducial that is fundamentally different from those employed in other calibration methods.Comment: 10 pages, 5 figures, submitted to Classical and Quantum Gravit
    • …
    corecore