375 research outputs found

    MIMAC : A micro-tpc matrix for directional detection of dark matter

    Full text link
    Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.Comment: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physic

    Improvements in the South African HIV care cascade: findings on 90-90-90 targets from successive population-representative surveys in North West Province.

    Get PDF
    IntroductionTo achieve epidemic control of HIV by 2030, countries aim to meet 90-90-90 targets to increase knowledge of HIV-positive status, initiation of antiretroviral therapy (ART) and viral suppression by 2020. We assessed the progress towards these targets from 2014 to 2016 in South Africa as expanded treatment policies were introduced using population-representative surveys.MethodsData were collected in January to March 2014 and August to November 2016 in Dr. Ruth Segomotsi Mompati District, North West Province. Each multi-stage cluster sample included 46 enumeration areas (EA), a target of 36 dwelling units (DU) per EA, and a single resident aged 18 to 49 per DU. Data collection included behavioural surveys, rapid HIV antibody testing and dried blood spot collection. We used weighted general linear regression to evaluate differences in the HIV care continuum over time.ResultsOverall, 1044 and 971 participants enrolled in 2014 and 2016 respectively with approximately 77% undergoing HIV testing. Despite increases in reported testing, known status among people living with HIV (PLHIV) remained similar at 68.7% (95% Confidence Interval (CI) = 60.9-75.6) in 2014 and 72.8% (95% CI = 63.6-80.4) in 2016. Men were consistently less likely than women to know their status. Among those with known status, PLHIV on ART increased significantly from 80.9% (95% CI = 71.9-87.4) to 91.5% (95% CI = 84.4-95.5). Viral suppression (<5000 copies/mL using DBS) among those on ART increased significantly from 55.0% (95% CI = 39.6-70.4) in 2014 to 81.4% (95% CI = 72.0-90.8) in 2016. Among all PLHIV an estimated 72.0% (95% CI = 63.8-80.1) of women and 45.8% (95% CI = 27.0-64.7) of men achieved viral suppression by 2016.ConclusionsOver a period during which fixed-dose combination was introduced, ART eligibility expanded, and efforts to streamline treatment were implemented, major improvements in the second and third 90-90-90 targets were achieved. Achieving the first 90 target will require targeted and improved testing models for men

    Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project

    Full text link
    Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.Comment: Proceedings of TWEPP-11, Vienna, Austria, 26-30 September 201

    Renal Cell Carcinoma with Angioleiomyoma-Like Stroma and Clear Cell Papillary Renal Cell Carcinoma: Exploring SDHB Protein Immunohistochemistry and the Relationship to Tuberous Sclerosis Complex

    Get PDF
    Renal cell carcinoma (RCC) with angioleiomyoma-like stroma appears to be molecularly distinct from clear cell RCC; however, its relationship to clear cell papillary RCC remains debated. Recent studies have found that similar tumors sometimes occur in patients with tuberous sclerosis complex (TSC), of which one study found unexpectedly negative succinate dehydrogenase (SDH) B immunostaining. We evaluated immunohistochemistry for SDHB in 12 apparently sporadic RCCs with angioleiomyoma-like stroma and correlated with clinical information for stigmata of TSC. Tumors were compared to a group of 16 clear cell papillary RCCs and 6 unclassified tumors with prominent stroma. With exception of 1 unclassified tumor, all exhibited at least focal cytoplasmic staining for SDHB protein, often requiring high magnification and better appreciated with increased antibody concentration. Detailed history information was available for 9/12 patients with smooth muscle-rich tumors, revealing no stigmata of undiagnosed TSC. Electron microscopy performed on 1 of these tumors revealed mitochondria to be very sparse, potentially accounting for the weak immunohistochemical labeling for SDHB protein. Weak SDHB immunostaining may represent another shared feature of RCC with angioleiomyoma-like stroma and clear cell papillary RCC, likely due to sparse mitochondria, strengthening the possible relationship of these entities. Although smooth muscle-rich tumors have been recently reported in patients with TSC, absence of staining in tumors with this pattern may not be specific for TSC. In tumors with pale or clear cytoplasm, immunohistochemical staining for SDHB should be interpreted with caution as evidence of abnormality in the SDH pathway

    A {\mu}-TPC detector for the characterization of low energy neutron fields

    Full text link
    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields

    Micromegas detector developments for MIMAC

    Full text link
    The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 Ă—\times 10 cm2^2 with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.Comment: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliation

    Probing the Local Velocity Distribution of WIMP Dark Matter with Directional Detectors

    Get PDF
    We explore the ability of directional nuclear-recoil detectors to constrain the local velocity distribution of weakly interacting massive particle (WIMP) dark matter by performing Bayesian parameter estimation on simulated recoil-event data sets. We discuss in detail how directional information, when combined with measurements of the recoil-energy spectrum, helps break degeneracies in the velocity-distribution parameters. We also consider the possibility that velocity structures such as cold tidal streams or a dark disk may also be present in addition to the Galactic halo. Assuming a carbon-tetrafluoride detector with a 30-kg-yr exposure, a 50-GeV WIMP mass, and a WIMP-nucleon spin-dependent cross-section of 0.001 pb, we show that the properties of a cold tidal stream may be well constrained. However, measurement of the parameters of a dark-disk component with a low lag speed of ~50 km/s may be challenging unless energy thresholds are improved.Comment: 38 pages, 15 figure
    • …
    corecore