164 research outputs found

    Trapping of single atoms in cavity QED

    Get PDF
    By integrating the techniques of laser cooling and trapping with those of cavity quantum electrodynamics (QED), single Cesium atoms have been trapped within the mode of a small, high finesse optical cavity in a regime of strong coupling. The observed lifetime for individual atoms trapped within the cavity mode is τ28\tau \approx 28ms, and is limited by fluctuations of light forces arising from the far-detuned intracavity field. This initial realization of trapped atoms in cavity QED should enable diverse protocols in quantum information science.Comment: 4 pages, 4 figure

    The optical calcium frequency standards of PTB and NIST

    Get PDF
    We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transition of 40Ca one of the best known optical frequencies (relative uncertainty 1.2e-14) and the measurements of this frequency in both laboratories agree to well within their respective uncertainties. Prospects for improvement by orders of magnitude in the relative uncertainty of the standard look feasible.Comment: 13 pages, 11 figures, to appear in Comptes Rendus Physiqu

    Ultra-cold atoms in an optical cavity: two-mode laser locking to the cavity avoiding radiation pressure

    Full text link
    The combination of ultra-cold atomic clouds with the light fields of optical cavities provides a powerful model system for the development of new types of laser cooling and for studying cooperative phenomena. These experiments critically depend on the precise tuning of an incident pump laser with respect to a cavity resonance. Here, we present a simple and reliable experimental tuning scheme based on a two-mode laser spectrometer. The scheme uses a first laser for probing higher-order transversal modes of the cavity having an intensity minimum near the cavity's optical axis, where the atoms are confined by a magnetic trap. In this way the cavity resonance is observed without exposing the atoms to unwanted radiation pressure. A second laser, which is phase-locked to the first one and tuned close to a fundamental cavity mode drives the coherent atom-field dynamics.Comment: 7 pages, 7 figure

    Relation of atrial natriuretic peptides to left ventricular systolic and diastolic function in heart failure

    Get PDF
    Background: Plasma concentrations of atrial natriuretic peptides are correlated with atrial pressures, as are left ventricular ejection fraction and left ventricular filling abnormalities. Aims: This study investigated the relation of atrial natriuretic peptides to both left ventricular systolic and diastolic function in heart failure. Methods: Plasma concentrations of atrial natriuretic peptide and N-terminal pro-atrial natriuretic peptide were measured in 63 patients with chronic heart failure and left ventricular systolic dysfunction. According to Doppler transmitral flow measurements, 19 patients had a restrictive and 44 patients had a non-restrictive left ventricular filling pattern. Results: Plasma concentrations of atrial natriuretic peptide and N-terminal pro-atrial natriuretic peptide were higher in patients with a restrictive filling pattern than in patients with a non-restrictive filling pattern (197 vs. 75 pmol/l, P < 0.0001 and 1.14 vs. 0.45 nmol/l, P < 0.0001). In univariate analysis, atrial natriuretic peptide and N-terminal pro-atrial natriuretic peptide correlated with deceleration time, E/A ratio and left ventricular ejection fraction. In multivariate analysis, both peptides appeared independently related to left ventricular ejection fraction and left ventricular filling pattern. Conclusion: In patients with chronic heart failure, atrial natriuretic peptides provide information on left ventricular systolic as well as diastolic function

    Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Biventricular (Biv) pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP) assessment by radial artery tonometry in guiding Biv pacemaker optimization.</p> <p>Methods</p> <p>Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV) ejection fraction (EF) 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI), ejection time (ET), myocardial performance index (MPI), radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated.</p> <p>Results</p> <p>Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p < 0.001), LV VTI (15.9 ± 4.8 cm to 18.4 ± 5.1 cm, p < 0.001) and MPI (0.57 ± 0.2 to 0.45 ± 0.13, p < 0.001) and in PEP (246.7 ± 36.1 ms to 234.7 ± 35.5 ms, p = 0.003), PEP/ET (0.88 ± 0.21 to 0.79 ± 0.17, p < 0.001), and PEP/VTI (17.3 ± 7 to 13.78 ± 4.7, p < 0.001). The correlation between comprehensive echo Doppler and radial artery tonometry-PEP guided optimal atrioventricular delay (AVD) and optimal interventricular delay (VVD) was 0.75 (p < 0.001) and 0.69 (p < 0.001) respectively. In 29 patients with follow up assessment, New York Heart Association (NYHA) class reduced from 2.5 ± 0.8 to 2.0 ± 0.9 (p = 0.004) at 1.8 ± 1.4 months.</p> <p>Conclusion</p> <p>An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.</p

    Can Echocardiographic Findings Predict Falls in Older Persons?

    Get PDF
    Background. The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. Method and Findings. In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4 SD 6.0) of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for compounders was performed with a Cox proportional hazards model. 557 patients (26%) fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 135 (95% Cl, 1.08-1.71) for pulmonary hypertension, 1.66 (95% Cl, 1.01 to 2.89) for 4-initial regurgitation, 2.41 (95% Cl, 1.32 to 4.37) for tricuspid regurgitation and 1.76 (95% Cl, 1.03 to 3.01) for pulmonary regurgitation. For aoitic regurgitation the risk of a fall was also increased, but non-significantly. (hazard ratio, 1.57 [95% Cl 0.85 to 2.92]). Trend analysis of the severity of the difterent regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. Conclusions. Echo(Dopler)cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo(Doppler)cardiogram in selected groups

    The NOX toolbox: validating the role of NADPH oxidases in physiology and disease

    Get PDF
    Reactive oxygen species (ROS) are cellular signals but also disease triggers; their relative excess (oxidative stress) or shortage (reductive stress) compared to reducing equivalents are potentially deleterious. This may explain why antioxidants fail to combat diseases that correlate with oxidative stress. Instead, targeting of disease-relevant enzymatic ROS sources that leaves physiological ROS signaling unaffected may be more beneficial. NADPH oxidases are the only known enzyme family with the sole function to produce ROS. Of the catalytic NADPH oxidase subunits (NOX), NOX4 is the most widely distributed isoform. We provide here a critical review of the currently available experimental tools to assess the role of NOX and especially NOX4, i.e. knock-out mice, siRNAs, antibodies, and pharmacological inhibitors. We then focus on the characterization of the small molecule NADPH oxidase inhibitor, VAS2870, in vitro and in vivo, its specificity, selectivity, and possible mechanism of action. Finally, we discuss the validation of NOX4 as a potential therapeutic target for indications including stroke, heart failure, and fibrosis
    corecore