147 research outputs found

    Interannual variability in net accumulation on the Greenland Ice Sheet: Observations and implications for mass balance measurements

    Get PDF
    This is the published version, also available here: http://dx.doi.org/10.1029/1998JD200082.Nine 24-year accumulation records from the Summit region in central Greenland are analyzed to separate the effects of spatial noise and interannual fluctuations on the variability in each core. The study shows that both processes are equally important, with standard deviations of 25 mm water equivalent per year and 24 mm water equivalent per year, respectively. A comparison with estimates of surface roughness based on high-resolution laser altimetry of the surface indicates that in the studied region the spatial noise can be reliably estimated from surface roughness. The response of the ice-sheet surface to the interannual fluctuations can be estimated using a simple zero-dimensional ice-sheet response model. For the Summit region of central Greenland, a change in surface elevation of ∼20 mm water equivalent per year measured over a 5-year period, can be attributed with 95% confidence to a trend in climate. This probability decreases rapidly as the observation period is shortened. For intervals greater than ∼5 year, the probability depends only weakly on the measurement interval. This suggests an optimum spacing of ∼5 years between repeat elevation measurements

    Surface roughness on the Greenland Ice Sheet from airborne laser altimetry

    Get PDF
    This is the published version, also available here: http://dx.doi.org/10.1029/1998GL900041.High resolution airborne laser altimetry is used to determine the small-scale surface relief in central Greenland and estimate the contribution from spatial noise to stratigraphic records. The standard deviation of the surface roughness is 1.6 cm water equivalent, corresponding to a standard deviation of annual layer thickness of 2.3 cm we. This estimate agrees with an independent assessment of the spatial variability (2.5 cm we) based on nine shallow ice cores. The agreement suggests that the statistical nature of the surface in central Greenland remains unchanged throughout the year. By conducting airborne altimetry around proposed drilling sites, the expected noise level in the core can be evaluated and sites selected where this level is lowest

    Influence of the Location of the Internal Temperature Control Loop on the Performance of the Dual Temperature Control for Feed Temperature Disturbance

    Get PDF
    A control strategy with distributed corrective action for distillation has been proposed and consists of a conventional dual temperature control combined with an additional column tray. In this work, we evaluated the influence of the location of this internal loop as part of the new proposal, compared to a conventional system. Tests were carried out in a 13-column tray distillation equipment and feed temperature was disturbed. Two different column trays from the stripping section were used (11 and 12) for internal decentralized temperature control, each one separately, plus the dual control of top and bottom temperatures. The results demonstrated that this proposed control approach with distributed corrective action is faster than the conventional one, regardless of the column tray in use. It was also determined that the internal loop close to the feed (disturbance) is more interesting as a way to minimize transients

    Características da carcaça e dos componentes não carcaça de cordeiros oriundos de parto simples ou duplo.

    Get PDF
    Resumo: Um experimento foi conduzido com o objetivo de avaliar as características da carcaça e dos componentes não carcaça de cordeiros nascidos de parto simples ou duplo. Dezesseis cordeiros mestiços Texel × Ile de France, machos não castrados, foram desmamados aos 56 dias de idade e abatidos com aproximadamente 28kg de peso corporal. Imediatamente após o abate, cada componente corporal foi pesado separadamente, sendo as carcaças avaliadas após 24 horas de refrigeração a 2°C. Os cordeiros oriundos de parto simples apresentaram superioridade no peso e nos rendimentos da carcaça, além de maior área de olho de lombo. Por outro lado, proporcionalmente ao peso de corpo vazio, o rúmen é maior em cordeiros nascidos de parto duplo, o que resulta incremento da proporção de conteúdo gastrintestinal ao abate. Os resultados deste estudo indicam que, quando abatidos a um mesmo peso, cordeiros oriundos de parto simples possuem carcaças de melhor qualidade, em comparação a cordeiros nascidos de parto gemelar. [Carcass and non-carcass traits of single and twin lambs]. Abstract: An experiment was conducted to evaluate the carcass and non-carcass traits of single and twin lambs. Sixteen Texel × Ile de France crossbred, non-castrated male lambs were weaned at 56 days of age and slaughtered at 28kg of body weight. Immediately after the slaughter each body component was individually weighed, while carcasses were evaluated after a 24h period of refrigeration at 2°C. Single lambs presented higher values of carcass weight and carcass dressing percentage. Moreover, the Longissimus muscle area was also greater for single lambs. On the other hand, as a proportion of empty body weight, rumen was greater for twin lambs, increasing their gastrointestinal content at slaughter. The results of this study indicated that at a same slaughter weight single lambs have better quality carcasses in comparison with those from twin lambs

    Precise phylogenetic analysis of microbial isolates and genomes from metagenomes using PhyloPhlAn 3.0

    Get PDF
    Microbial genomes are available at an ever-increasing pace, as cultivation and sequencing become cheaper and obtaining metagenome-assembled genomes (MAGs) becomes more effective. Phylogenetic placement methods to contextualize hundreds of thousands of genomes must thus be efficiently scalable and sensitive from closely related strains to divergent phyla. We present PhyloPhlAn 3.0, an accurate, rapid, and easy-to-use method for large-scale microbial genome characterization and phylogenetic analysis at multiple levels of resolution. PhyloPhlAn 3.0 can assign genomes from isolate sequencing or MAGs to species-level genome bins built from >230,000 publically available sequences. For individual clades of interest, it reconstructs strain-level phylogenies from among the closest species using clade-specific maximally informative markers. At the other extreme of resolution, it scales to large phylogenies comprising >17,000 microbial species. Examples including Staphylococcus aureus isolates, gut metagenomes, and meta-analyses demonstrate the ability of PhyloPhlAn 3.0 to support genomic and metagenomic analyses

    Theoretical study of the insulating oxides and nitrides: SiO2, GeO2, Al2O3, Si3N4, and Ge3N4

    Get PDF
    An extensive theoretical study is performed for wide bandgap crystalline oxides and nitrides, namely, SiO_{2}, GeO_{2}, Al_{2}O_{3}, Si_{3}N_{4}, and Ge_{3}N_{4}. Their important polymorphs are considered which are for SiO_{2}: α\alpha-quartz, α\alpha- and β\beta-cristobalite and stishovite, for GeO_{2}: α\alpha-quartz, and rutile, for Al_{2}O_{3}: α\alpha-phase, for Si_{3}N_{4} and Ge_{3}N_{4}: α\alpha- and β\beta-phases. This work constitutes a comprehensive account of both electronic structure and the elastic properties of these important insulating oxides and nitrides obtained with high accuracy based on density functional theory within the local density approximation. Two different norm-conserving \textit{ab initio} pseudopotentials have been tested which agree in all respects with the only exception arising for the elastic properties of rutile GeO_{2}. The agreement with experimental values, when available, are seen to be highly satisfactory. The uniformity and the well convergence of this approach enables an unbiased assessment of important physical parameters within each material and among different insulating oxide and nitrides. The computed static electric susceptibilities are observed to display a strong correlation with their mass densities. There is a marked discrepancy between the considered oxides and nitrides with the latter having sudden increase of density of states away from the respective band edges. This is expected to give rise to excessive carrier scattering which can practically preclude bulk impact ionization process in Si_{3}N_{4} and Ge_{3}N_{4}.Comment: Published version, 10 pages, 8 figure

    A germanate transparent conductive oxide

    Get PDF
    Wide bandgap conductors such as In2O3 and ZnO are used as transparent conducting oxides (TCOs). To date, TCOs are realized using post transition metal cations with largely spread s-orbitals such as In3+, Sn4+, Zn2+ and Cd2+. On the other hand, no good electronic conductor has been realized in oxides of Al, Si and Ge. Here we report the conversion of an oxide of Ge into a good electronic conductor by employing the concept of superdegeneracy. We find that cubic SrGeO3, synthesized under high pressure, displays a direct bandgap of 3.5 eV, a carrier mobility of 12 cm2(Vs)−1, and conductivities of 3 Scm−1 (DC) and 400 Scm−1 (optical conductivity). This is the first Ge-based electronic conductive oxide, and expands the family of TCOs from ionic oxides to covalent oxides

    The Greenland Ice Sheet Project 2 Depth-age Scale: Methods and Results

    Get PDF
    The Greenland Ice Sheet Project 2 (GISP2) depth-age scale is presented based on a multiparameter continuous count approach, to a depth of 2800 m, using a systematic combination of parameters that have never been used to this extent before. The ice at 2800 m is dated at 110,000 years B.P. with an estimated error ranging from 1 to 10% in the top 2500 m of the core and averaging 20% between 2500 and 2800 m. Parameters used to date the core include visual stratigraphy, oxygen isotopic ratios of the ice, electrical conductivity measurements, laser-light scattering from dust, volcanic signals, and major ion chemistry. GISP2 ages for major climatic events agree with independent ages based on varve chronologies, calibrated radiocarbon dates, and other techniques within the combined uncertainties. Good agreement also is obtained with Greenland Ice Core Project ice core dates and with the SPECMAP marine timescale after correlation through the δ18O of O2. Although the core is deformed below 2800 m and the continuity of the record is unclear, we attempted to date this section of the core on the basis of the laser-light scattering of dust in the ice

    Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    Get PDF
    Background: Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. the aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA).Methods: Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5.Results: in both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups.Conclusion: Subxyphoid insertion of pleural drain provides similar effects to preserved pleural integrity in pulmonary function, clinical outcomes, and thoracic pain after OPCAB. Therefore, our results support the hypothesis that once pleural cavities are incidentally or purposely opened during LITA dissection, subxyphoid placement of the pleural drain is recommended.Universidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Physiotherapy Sch, Dept Human Movement Sci, BR-11060001 Santos, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Pneumol Discipline, BR-04039002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiol Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Physiotherapy Sch, Dept Human Movement Sci, BR-11060001 Santos, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Pneumol Discipline, BR-04039002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, Pirajussara Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilUniversidade Federal de São Paulo, Escola Paulista Med, São Paulo Hosp, Dept Med,Cardiovasc Surg Discipline, BR-04024002 São Paulo, BrazilWeb of Scienc
    corecore