29 research outputs found

    Evaluation of Oxacillin and Cefoxitin Disk and MIC Breakpoints for Prediction of Methicillin Resistance in Human and Veterinary Isolates of Staphylococcus intermedius Group

    Get PDF
    Staphylococcus pseudintermedius is a coagulase-positive species that colonizes the nares and anal mucosa of healthy dogs and cats. Human infections with S. pseudintermedius range in severity from bite wounds and rhinosinusitis to endocarditis; historically, these infections were thought to be uncommon, but new laboratory methods suggest that their true incidence is underreported. Oxacillin and cefoxitin disk and MIC tests were evaluated for the detection of mecA- or mecC-mediated methicillin resistance in 115 human and animal isolates of the Staphylococcus intermedius group (SIG), including 111 Staphylococcus pseudintermediusand 4 Staphylococcus delphini isolates, 37 of which were mecA positive. The disk and MIC breakpoints evaluated included the Clinical and Laboratory Standards Institute (CLSI) M100-S25 Staphylococcus aureus/Staphylococcus lugdunensis oxacillin MIC breakpoints and cefoxitin disk and MIC breakpoints, the CLSI M100-S25 coagulase-negative Staphylococcus (CoNS) oxacillin MIC breakpoint and cefoxitin disk breakpoint, the CLSI VET01-S2 S. pseudintermedius oxacillin MIC and disk breakpoints, and the European Committee on Antimicrobial Susceptibility Testing (EUCAST) S. pseudintermedius cefoxitin disk breakpoint. The oxacillin results interpreted by the VET01-S2 (disk and MIC) and M100-S25 CoNS (MIC) breakpoints agreed with the results of mecA/mecC PCR for all isolates, with the exception of one false-resistant result (1.3% of mecA/mecC PCR-negative isolates). In contrast, cefoxitin tests performed poorly, ranging from 3 to 89% false susceptibility (very major errors) and 0 to 48% false resistance (major errors). BD Phoenix, bioMérieux Vitek 2, and Beckman Coulter MicroScan commercial automated susceptibility test panel oxacillin MIC results were also evaluated and demonstrated >95% categorical agreement with mecA/mecC PCR results if interpreted by using the M100-S25 CoNS breakpoint. The Alere penicillin-binding protein 2a test accurately detected all mecA-positive isolates, although for four isolates, cefoxitin induction was required prior to testing. These data demonstrate that the cefoxitin surrogate test does not reliably detect the presence of mecA in S. pseudintermedius isolates and that laboratories should perform oxacillin disk or MIC tests of these isolates when they are encountered

    Enterovirus D68 outbreak detection through a syndromic disease epidemiology network

    Get PDF
    BACKGROUND: In 2014, enterovirus D68 (EV-D68) was responsible for an outbreak of severe respiratory illness in children, with 1,153 EV-D68 cases reported across 49 states. Despite this, there is no commercial assay for its detection in routine clinical care. BioFire® Syndromic Trends (Trend) is an epidemiological network that collects, in near real-time, deidentified. BioFire test results worldwide, including data from the BioFire® Respiratory Panel (RP). OBJECTIVES: Using the RP version 1.7 (which was not explicitly designed to differentiate EV-D68 from other picornaviruses), we formulate a model, Pathogen Extended Resolution (PER), to distinguish EV-D68 from other human rhinoviruses/enteroviruses (RV/EV) tested for in the panel. Using PER in conjunction with Trend, we survey for historical evidence of EVD68 positivity and demonstrate a method for prospective real-time outbreak monitoring within the network. STUDY DESIGN: PER incorporates real-time polymerase chain reaction metrics from the RPRV/EV assays. Six institutions in the United States and Europe contributed to the model creation, providing data from 1,619 samples spanning two years, confirmed by EV-D68 gold-standard molecular methods. We estimate outbreak periods by applying PER to over 600,000 historical Trend RP tests since 2014. Additionally, we used PER as a prospective monitoring tool during the 2018 outbreak. RESULTS: The final PER algorithm demonstrated an overall sensitivity and specificity of 87.1% and 86.1%, respectively, among the gold-standard dataset. During the 2018 outbreak monitoring period, PER alerted the research network of EV-D68 emergence in July. One of the first sites to experience a significant increase, Nationwide Children's Hospital, confirmed the outbreak and implemented EV-D68 testing at the institution in response. Applying PER to the historical Trend dataset to determine rates among RP tests, we find three potential outbreaks with predicted regional EV-D68 rates as high as 37% in 2014, 16% in 2016, and 29% in 2018. CONCLUSIONS: Using PER within the Trend network was shown to both accurately predict outbreaks of EV-D68 and to provide timely notifications of its circulation to participating clinical laboratories

    Exploring the IL-21–STAT3 Axis as Therapeutic Target for Sézary Syndrome

    Get PDF
    Sézary syndrome is an aggressive cutaneous T-cell lymphoma. The malignant cells (Sézary cells) are present in skin, lymph nodes, and blood, and express constitutively activated signal transducer and activator of transcription (STAT)3. STAT3 can be activated by IL-21 in vitro and the IL-21 gene itself is a STAT3 target gene, thereby creating an autocrine positive feedback loop that might serve as a therapeutic target. Sézary cells underwent apoptosis when incubated with Stattic, a selective STAT3 inhibitor. STAT3 activation in Sézary cells did not affect expression of the supposed anti-apoptotic STAT3 target genes BCL2, BCL-xL, and SURVIVIN, whereas expression of (proto)oncogenes miR-21, TWIST1, MYC, and PIM1 was significantly increased. CD3/CD28-mediated activation of Sézary cells induced IL-21 expression, accompanied by STAT3 activation and increased proliferation. Blocking IL-21 in CD3/CD28-activated cells had no effects, whereas Stattic abrogated IL-21 expression and cell proliferation. Thus, specific inhibition of STAT3 is highly efficient in the induction of apoptosis of Sézary cells, likely mediated via the regulation of (proto)oncogenes. In contrast, blocking IL-21 alone seems insufficient to affect STAT3 activation, cell proliferation, or apoptosis. These data provide further insights into the pathogenic role of STAT3 in Sézary syndrome and strengthen the notion that STAT3 represents a promising therapeutic target in this disease

    322. Evaluation of the BioFire® Bone and Joint Infection (BJI) Panel for the Detection of Microorganisms and Antimicrobial Resistance Genes in Synovial Fluid Specimens

    Get PDF
    Background Bone and Joint Infections (BJIs) present with non-specific symptoms that may include pain, swelling, and fever and are associated with high morbidity and significant risk of mortality. BJIs can be caused by a variety of bacteria and fungi, including anaerobes and microorganisms that can be challenging to culture or identify by traditional microbiological methods. Clinicians primarily rely on culture to identify the pathogen(s) responsible for infection. The BioFire® Bone and Joint Infection (BJI) Panel (BioFire Diagnostics, Salt Lake City, UT) is designed to detect 15 gram-positive bacteria (including seven anaerobes), 14 gram-negative bacteria (including one anaerobe), two yeast, and eight antimicrobial resistance (AMR) genes from synovial fluid specimens in about an hour. The objective of this study was to evaluate the performance of an Investigational Use Only (IUO) version of the BioFire BJI Panel compared to various reference methods. Methods Remnant synovial fluid specimens, which were collected for routine clinical care at 13 study sites in the US and Europe, underwent testing using an IUO version of the BioFire BJI Panel. Performance of this test was determined by comparison to Standard of Care (SoC) consisting of bacterial culture performed at each study site according to their routine procedures. Results A total of 1544 synovial fluid specimens were collected and tested with the BioFire BJI Panel. The majority of specimens were from knee joints (77.9%) and arthrocentesis (79.4%) was the most common collection method. Compared to SoC culture, overall sensitivity was 90.2% and specificity was 99.8%. The BioFire BJI Panel yielded a total of 268 Detected results, whereas SoC yielded a total of 215 positive results for on-panel analytes. Conclusion The BioFire BJI Panel is a sensitive, specific, and robust test for rapid detection of a wide range of analytes in synovial fluid specimens. The number of microorganisms and resistance genes included in the BioFire BJI Panel, together with a reduced time-to-result and increased diagnostic yield compared to culture, is expected to aid in the timely diagnosis and appropriate management of BJIs

    Roseomonas mucosa Isolated from Bloodstream of Pediatric Patient ▿

    No full text
    We report a case of catheter-related bacteremia associated with Roseomonas mucosa isolated from an immunocompromised pediatric patient with a history of multiple episodes of urinary tract infection and bacteremia

    Enterovirus D68 outbreak detection through a syndromic disease epidemiology network

    No full text
    © 2020 Background: In 2014, enterovirus D68 (EV-D68) was responsible for an outbreak of severe respiratory illness in children, with 1,153 EV-D68 cases reported across 49 states. Despite this, there is no commercial assay for its detection in routine clinical care. BioFire® Syndromic Trends (Trend) is an epidemiological network that collects, in near real-time, deidentified. BioFire test results worldwide, including data from the BioFire® Respiratory Panel (RP). Objectives: Using the RP version 1.7 (which was not explicitly designed to differentiate EV-D68 from other picornaviruses), we formulate a model, Pathogen Extended Resolution (PER), to distinguish EV-D68 from other human rhinoviruses/enteroviruses (RV/EV) tested for in the panel. Using PER in conjunction with Trend, we survey for historical evidence of EVD68 positivity and demonstrate a method for prospective real-time outbreak monitoring within the network. Study design: PER incorporates real-time polymerase chain reaction metrics from the RPRV/EV assays. Six institutions in the United States and Europe contributed to the model creation, providing data from 1,619 samples spanning two years, confirmed by EV-D68 gold-standard molecular methods. We estimate outbreak periods by applying PER to over 600,000 historical Trend RP tests since 2014. Additionally, we used PER as a prospective monitoring tool during the 2018 outbreak. Results: The final PER algorithm demonstrated an overall sensitivity and specificity of 87.1% and 86.1%, respectively, among the gold-standard dataset. During the 2018 outbreak monitoring period, PER alerted the research network of EV-D68 emergence in July. One of the first sites to experience a significant increase, Nationwide Children\u27s Hospital, confirmed the outbreak and implemented EV-D68 testing at the institution in response. Applying PER to the historical Trend dataset to determine rates among RP tests, we find three potential outbreaks with predicted regional EV-D68 rates as high as 37% in 2014, 16% in 2016, and 29% in 2018. Conclusions: Using PER within the Trend network was shown to both accurately predict outbreaks of EV-D68 and to provide timely notifications of its circulation to participating clinical laboratorie
    corecore