201 research outputs found

    Linear Temperature Variation of the Penetration Depth in YBCO Thin Films

    Full text link
    We have measured the penetration depth λ(T)\lambda(T) on YBa2Cu3O7\rm YBa_{2}Cu_{3}O_{7} thin films from transmission at 120, 330 and 510~GHz, between 5 and 50~K. Our data yield simultaneously the absolute value and the temperature dependence of λ(T)\lambda(T). In high quality films λ(T)\lambda(T) exhibits the same linear temperature dependence as single crystals, showing its intrinsic nature, and λ(0)=1750 A˚\lambda(0)=1750\,{\rm \AA}. In a lower quality one, the more usual T2T^2 dependence is found, and λ(0)=3600 A˚\lambda(0)=3600\,{\rm \AA}. This suggests that the T2T^2 variation is of extrinsic origin. Our results put the dd-wave like interpretation in a much better position.Comment: 12 pages, revtex, 4 uuencoded figure

    Comparative Analysis of the Measured and Extrapolated Wind Shear Distributions at Murtala Mohammed and Port Harcourt International Airports, Nigeria

    Get PDF
    The persistent gory incidents, accidents, loss of huge amount of money and outcry by the aviation industry for accurate weather observation and forecast have been of utmost worry to so many researchers. In a bid to curbing these aviation weather challenges, researchers have discovered that wind shear impacts greatly on flight operations in the airports, and are working towards ameliorating the effects. This study analyzed the distribution of measured and extrapolated wind shear at Murtala Mohammed and Port Harcourt International Airports, Nigeria. The annual time series secondary data used for this study were sourced from Nigerian Airspace Management Agency (NAMA) at Murtala Mohammed and Port Harcourt International Airports and Nigerian Meteorological Agency (NIMET). Power Law Model was used to extrapolate wind shear at 20m above ground level to 50m and 100m above ground level for the both airports. The data were compiled and presented in tables and charts for easy understanding and further analysis. The statistical techniques employed in achieving the research target were descriptive statistics (such as mean, standard deviations, coefficient of variation and charts). The study shows that wind shear increases with altitude at the study areas due to decrease in frictional resistance which is more pronounced close to the ground. A similarity in the distribution pattern of wind shear at 20m, 50m and 100m above ground level at Murtala Mohammed International Airport was revealed by the study. The same similarity in the distribution pattern was also revealed at Port Harcourt International Airport. Evidently, the study reveals some temporal variations in the mean and standard deviation of wind shear in the study areas. The study also reveals based on the effects of wind shear and its resultant flight delays, diversions and cancellations that Port Harcourt International Airport with overall higher coefficient of variation (CV) is considered safer for flight landing. The study therefore, based on its findings, recommends subsequent training and retraining of Meteorologists, Pilots and Air Traffic Controllers on wind shear and related weather issues. The work also recommends that more studies should be carried out by the students and researchers on wind shear. Keywords: Wind Shear, Comparative Analysis, Measured, Extrapolated, Distributions DOI: 10.7176/JEES/11-5-06 Publication date:May 31st 202

    Inverse Spin Hall Effect in nanometer-thick YIG/Pt system

    Full text link
    High quality nanometer-thick (20 nm, 7 nm and 4 nm) epitaxial YIG films have been grown on GGG substrates using pulsed laser deposition. The Gilbert damping coefficient for the 20 nm thick films is 2.3 x 10-4 which is the lowest value reported for sub-micrometric thick films. We demonstrate Inverse spin Hall effect (ISHE) detection of propagating spin waves using Pt. The amplitude and the lineshape of the ISHE voltage correlate well to the increase of the Gilbert damping when decreasing thickness of YIG. Spin Hall effect based loss-compensation experiments have been conducted but no change in the magnetization dynamics could be detected

    Joule heating and high frequency nonlinear effects in the surface impedance of high Tc superconductors

    Get PDF
    Using the dielectric resonator method, we have investigated nonlinearities in the surface impedance Zs = Rs + jXs of YBa2Cu3O7 thin films at 10 GHz as function of the incident microwave power level and temperature. The use of a rutile dielectric resonator allows us to measure the precise temperature of the films. We conclusively show that the usually observed increase of the surface resistance of YBa2Cu3O7 thin film as function of microwave power is due to local heating

    Sexual dimorphism in relation to adipose tissue and intrahepatocellular lipid deposition in early infancy

    Get PDF
    Sexual dimorphism in adiposity is well described in adults, but the age at which differences first manifest is uncertain. Using a prospective cohort, we describe longitudinal changes in directly measured adiposity and intrahepatocellular lipid (IHCL) in relation to sex in healthy term infants. At median ages of 13 and 63 days, infants underwent quantification of adipose tissue depots by whole-body magnetic resonance imaging and measurement of IHCL by in vivo proton magnetic resonance spectroscopy. Longitudinal data were obtained from 70 infants (40 boys and 30 girls). In the neonatal period girls are more adipose in relation to body size than boys. At follow-up (median age 63 days), girls remained significantly more adipose. The greater relative adiposity that characterises girls is explained by more subcutaneous adipose tissue and this becomes increasingly apparent by follow-up. No significant sex differences were seen in IHCL. Sex-specific differences in infant adipose tissue distribution are in keeping with those described in later life, and suggest that sexual dimorphism in adiposity is established in early infancy

    Further investigation of confirmed urinary tract infection (UTI) in children under five years: a systematic review.

    Get PDF
    Background: Further investigation of confirmed UTI in children aims to prevent renal scarring and future complications. Methods: We conducted a systematic review to determine the most effective approach to the further investigation of confirmed urinary tract infection (UTI) in children under five years of age. Results: 73 studies were included. Many studies had methodological limitations or were poorly reported. Effectiveness of further investigations: One study found that routine imaging did not lead to a reduction in recurrent UTIs or renal scarring. Diagnostic accuracy: The studies do not support the use of less invasive tests such as ultrasound as an alternative to renal scintigraphy, either to rule out infection of the upper urinary tract (LR- = 0.57, 95%CI: 0.47, 0.68) and thus to exclude patients from further investigation or to detect renal scarring (LR+ = 3.5, 95% CI: 2.5, 4.8). None of the tests investigated can accurately predict the development of renal scarring. The available evidence supports the consideration of contrast-enhanced ultrasound techniques for detecting vesico-ureteric reflux (VUR), as an alternative to micturating cystourethrography (MCUG) (LR+ = 14.1, 95% CI: 9.5, 20.8; LR- = 0.20, 95%CI: 0.13, 0.29); these techniques have the advantage of not requiring exposure to ionising radiation. Conclusion: There is no evidence to support the clinical effectiveness of routine investigation of children with confirmed UTI. Primary research on the effectiveness, in terms of improved patient outcome, of testing at all stages in the investigation of confirmed urinary tract infection is urgently required

    How does study quality affect the results of a diagnostic meta-analysis?

    Get PDF
    Background: The use of systematic literature review to inform evidence based practice in diagnostics is rapidly expanding. Although the primary diagnostic literature is extensive, studies are often of low methodological quality or poorly reported. There has been no rigorously evaluated, evidence based tool to assess the methodological quality of diagnostic studies. The primary objective of this study was to determine the extent to which variations in the quality of primary studies impact the results of a diagnostic meta-analysis and whether this differs with diagnostic test type. A secondary objective was to contribute to the evaluation of QUADAS, an evidence-based tool for the assessment of quality in diagnostic accuracy studies. Methods: This study was conducted as part of large systematic review of tests used in the diagnosis and further investigation of urinary tract infection (UTI) in children. All studies included in this review were assessed using QUADAS, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. The impact of individual components of QUADAS on a summary measure of diagnostic accuracy was investigated using regression analysis. The review divided the diagnosis and further investigation of UTI into the following three clinical stages: diagnosis of UTI, localisation of infection, and further investigation of the UTI. Each stage used different types of diagnostic test, which were considered to involve different quality concerns. Results: Many of the studies included in our review were poorly reported. The proportion of QUADAS items fulfilled was similar for studies in different sections of the review. However, as might be expected, the individual items fulfilled differed between the three clinical stages. Regression analysis found that different items showed a strong association with test performance for the different tests evaluated. These differences were observed both within and between the three clinical stages assessed by the review. The results of regression analyses were also affected by whether or not a weighting (by sample size) was applied. Our analysis was severely limited by the completeness of reporting and the differences between the index tests evaluated and the reference standards used to confirm diagnoses in the primary studies. Few tests were evaluated by sufficient studies to allow meaningful use of meta-analytic pooling and investigation of heterogeneity. This meant that further analysis to investigate heterogeneity could only be undertaken using a subset of studies, and that the findings are open to various interpretations. Conclusion: Further work is needed to investigate the influence of methodological quality on the results of diagnostic meta-analyses. Large data sets of well-reported primary studies are needed to address this question. Without significant improvements in the completeness of reporting of primary studies, progress in this area will be limited

    Global Intraurban Intake Fractions for Primary Air Pollutants from Vehicles and Other Distributed Sources

    Get PDF
    We model intraurban intake fraction (iF) values for distributed ground-level emissions in all 3646 global cities with more than 100,000 inhabitants, encompassing a total population of 2.0 billion. For conserved primary pollutants, population-weighted median, mean, and interquartile range iF values are 26, 39, and 14-52 ppm, respectively, where 1 ppm signifies 1 g inhaled/t emitted. The global mean urban iF reported here is roughly twice as large as previous estimates for cities in the United States and Europe. Intake fractions vary among cities owing to differences in population size, population density, and meteorology. Sorting by size, population-weighted mean iF values are 65, 35, and 15 ppm, respectively, for cities with populations larger than 3, 0.6-3, and 0.1-0.6 million. The 20 worldwide megacities (each >10 million people) have a population-weighted mean iF of 83 ppm. Mean intraurban iF values are greatest in Asia and lowest in land-rich high-income regions. Country-average iF values vary by a factor of 3 among the 10 nations with the largest urban populations
    • …
    corecore