272 research outputs found

    Bose--Einstein Condensation in the Large Deviations Regime with Applications to Information System Models

    Full text link
    We study the large deviations behavior of systems that admit a certain form of a product distribution, which is frequently encountered both in Physics and in various information system models. First, to fix ideas, we demonstrate a simple calculation of the large deviations rate function for a single constraint (event). Under certain conditions, the behavior of this function is shown to exhibit an analogue of Bose--Einstein condensation (BEC). More interestingly, we also study the large deviations rate function associated with two constraints (and the extension to any number of constraints is conceptually straightforward). The phase diagram of this rate function is shown to exhibit as many as seven phases, and it suggests a two--dimensional generalization of the notion of BEC (or more generally, a multi--dimensional BEC). While the results are illustrated for a simple model, the underlying principles are actually rather general. We also discuss several applications and implications pertaining to information system models

    Pro-/antiinflammatory dysregulation in early psychosis: Results from a 1-year follow-Up study

    Get PDF
    Background: Previous studies indicated a systemic deregulation of the pro-/antiinflammatory balance in subjects after 6 months of a first psychotic episode. This disruption was reexamined 12 months after diagnosis to identify potential risk/ protective factors and associations with symptom severity. Methods: Eighty-five subjects were followed during 12 months and the determination of the same pro-/antiinflammatory mediators was carried out in plasma and peripheral blood mononuclear cells. Multivariate logistic regression analyses were used to identify risk/protective factors. Multiple linear regression models were performed to detect the change of each biological marker during follow-up in relation to clinical characteristics and confounding factors. Results: This study suggests a more severe systemic pro-/antiinflammatory deregulation than in earlier pathological stages in first psychotic episode, because not only were intracellular components of the inflammatory response increased but also the majority of soluble elements. Nitrite plasma levels and cyclooxygenase-2 expression in peripheral blood mononuclear cells are reliable potential risk factors and 15d-prostaglandin-J2 plasma levels a protection biomarker. An interesting relationship exists between antipsychotic dose and the levels of prostaglandin-E2 (inverse) and 15d-prostaglandin-J2 (direct). An inverse relationship between the Global Assessment of Functioning scale and lipid peroxidation is also present. Conclusions: Summing up, pro-/antiinflammatory mediators can be used as risk/protection biomarkers. The inverse association between oxidative/nitrosative damage and the Global Assessment of Functioning scale, and the possibility that one of the targets of antipsychotics could be the restoration of the pro-/antiinflammatory balance support the use of antiinflammatory drugs as coadjuvant to antipsychotics

    Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye

    Get PDF
    Abstract: A reliable and objective method to measure aberration changes due to the tear film is essential in improving clinical assessment of the tear film and in vivo retinal imaging. The tear film of 11 subjects are studied by acquiring continuous wavefront measurements in real-time with a customized Shack-Hartmann wavefront sensor. The device has a high resolution lenslet array (190 ”m) and a topographer unit with an infrared pupil illuminator (940 nm). A Fourier transform reconstructor algorith

    Medically unexplained pain complaints are associated with underlying unrecognized mood disorders in primary care

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patients with chronic pain frequently display comorbid depression, but the impact of this concurrence is often underestimated and mistreated. The aim of this study was to determine the prevalence of unrecognized major depression and other mood disorders and comorbid unexplained chronic pain in primary care settings and to explore the associated factors.</p> <p>Also, to compare the use of health services by patients with unexplained chronic pain, both with and without mood disorder comorbidity.</p> <p>Methods</p> <p>A cross-sectional study was carried out in a sample of primary care centers. 3189 patients consulting for "unexplained chronic pain" were assessed by the Visual Analogue Scales (VAS) and the Primary Care Evaluation of Mental Disorders (PRIME-MD) questionnaire.</p> <p>Results</p> <p>We report: a) a high prevalence of unrecognized mood disorders in patients suffering from unexplained chronic pain complaints (80.4%: CI 95%: 79.0%; 81.8%); b) a greater susceptibility of women to mood disorders (OR adjusted = 1.48; CI 95%:1.22; 1.81); c) a direct relationship between the prevalence of mood disorders and the duration of pain (OR adjusted = 1.01; CI 95%: 1.01; 1.02) d) a higher comorbidity with depression if the pain etiology was unknown (OR adjusted = 1.74; CI 95%: 1.45; 2.10) and, e) an increased use of health care services in patients with such a comorbidity (p < 0.0001).</p> <p>Conclusions</p> <p>The prevalence of undiagnosed mood disorders in patients with unexplained chronic pain in primary care is very high, leading to dissatisfaction with treatment processes and poorer outcomes. Consequently, it seems necessary to explore this condition more regularly in general practice in order to reach accurate diagnoses and to select the appropriate treatment.</p

    Walking on common ground: a cross-disciplinary scoping review on the clinical utility of digital mobility outcomes

    Get PDF
    Physical mobility is essential to health, and patients often rate it as a high-priority clinical outcome. Digital mobility outcomes (DMOs), such as real-world gait speed or step count, show promise as clinical measures in many medical conditions. However, current research is nascent and fragmented by discipline. This scoping review maps existing evidence on the clinical utility of DMOs, identifying commonalities across traditional disciplinary divides. In November 2019, 11 databases were searched for records investigating the validity and responsiveness of 34 DMOs in four diverse medical conditions (Parkinson’s disease, multiple sclerosis, chronic obstructive pulmonary disease, hip fracture). Searches yielded 19,672 unique records. After screening, 855 records representing 775 studies were included and charted in systematic maps. Studies frequently investigated gait speed (70.4% of studies), step length (30.7%), cadence (21.4%), and daily step count (20.7%). They studied differences between healthy and pathological gait (36.4%), associations between DMOs and clinical measures (48.8%) or outcomes (4.3%), and responsiveness to interventions (26.8%). Gait speed, step length, cadence, step time and step count exhibited consistent evidence of validity and responsiveness in multiple conditions, although the evidence was inconsistent or lacking for other DMOs. If DMOs are to be adopted as mainstream tools, further work is needed to establish their predictive validity, responsiveness, and ecological validity. Cross-disciplinary efforts to align methodology and validate DMOs may facilitate their adoption into clinical practice

    Evaluation of the prophylactic use of mitomycin-C to inhibit haze formation after photorefractive keratectomy in high myopia: a prospective clinical study

    Get PDF
    BACKGROUND: To study the effect of prophylactic application of mitomycin-C on haze formation in photorefractive keratectomy (PRK) for high myopia. METHODS: Fifty-four eyes of 28 myopic patients were enrolled in this prospective study. All eyes were operated by PRK followed by 0.02% mitomycin-C application for two minutes and washed with 20 ml normal saline afterwards. All eyes were examined thoroughly on the first 7 days and one month after surgery; 48 eyes (88.9%) at 3 and 6 months postoperatively. Hanna grading (in the scale of 0 to 4+) was used for assessment of corneal haze. RESULTS: The mean spherical equivalent refraction (SE) was -7.08 diopters (D) ± 1.11 (SD) preoperatively. Six months after surgery, 37 eyes (77.1%) achieved an uncorrected visual acuity (UCVA) of 20/20 or better, all eyes had a UCVA of 20/40 or better and 45 (93.7%) eyes had an SE within ± 1.00D. One month postoperatively, 2 eyes (3.7%) had grade 0.5+ of haze, while at 3 and 6 months after surgery no visited eye had haze at all. All eyes had a best corrected visual acuity (BCVA) of 20/40 or better and there were no lost lines in BCVA by 6 months after surgery. In spatial frequencies of 6 and 12 cycles per degree contrast sensitivity had decreased immediately after PRK and it had increased 1.5 lines by the 6(th )postoperative month compared to the preoperative data. CONCLUSIONS: The results show the efficacy of mitomycin-C in preventing corneal haze after treatment of high myopia with PRK. This method- PRK + mitomycin-C – can be considered an alternative treatment for myopic patients whose corneal thicknesses are inadequate for laser in situ keratomileusis (LASIK). However, the results should be confirmed in longer follow-ups

    The Effect of Tear Supplementation on Ocular Surface Sensations during the Interblink Interval in Patients with Dry Eye.

    Get PDF
    PURPOSE: To investigate the characteristics of ocular surface sensations and corneal sensitivity during the interblink interval before and after tear supplementation in dry eye patients. METHODS: Twenty subjects (41.88+/-14.37 years) with dry eye symptoms were included in the dry eye group. Fourteen subjects (39.13+/-11.27 years) without any clinical signs and/or symptoms of dry eye were included in the control group. Tear film dynamics was assessed by non-invasive tear film breakup time (NI-BUT) in parallel with continuous recordings of ocular sensations during forced blinking. Corneal sensitivity to selective stimulation of corneal mechano-, cold and chemical receptors was assessed using a gas esthesiometer. All the measurements were made before and 5 min after saline and hydroxypropyl-guar (HP-guar) drops. RESULTS: In dry eye patients the intensity of irritation increased rapidly after the last blink during forced blinking, while in controls there was no alteration in the intensity during the first 10 sec followed by an exponential increase. Irritation scores were significantly higher in dry eye patients throughout the entire interblink interval compared to controls (p0.05). CONCLUSION: Ocular surface irritation responses due to tear film drying are considerably increased in dry eye patients compared to normal subjects. Although tear supplementation improves the protective tear film layer, and thus reduce unpleasant sensory responses, the rapid rise in discomfort is still maintained and might be responsible for the remaining complaints of dry eye patients despite the treatment

    The HEV Ventilator

    Full text link
    HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.Comment: 34 pages, 18 figures, Extended version of the article submitted to PNA

    Correction to: Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium (<em>Journal of NeuroEngineering and Rehabilitation</em>, (2023), 20, 1, (78), 10.1186/s12984-023-01198-5)

    Get PDF
    \ua9 The Author(s) 2024.Following publication of the original article [1], the author noticed the errors in Table 1, and in Discussion section. In Table 1 under Metric (Gait sequence detection) column, the algorithms GSDB was updated with wrong description, input, output, language and citation and GSDc with wrong description has been corrected as shown below: (Table presented.) Description of algorithms for each metric: gait sequence detection (GSD), initial contact event detection (ICD), cadence estimation (CAD) and stride length estimation (SL) Metric Name Description Input Output Language References GSDA Based on a frequency-based approach, this algorithm is implemented on the vertical and anterior–posterior acceleration signals. First, these are band pass filtered to keep frequencies between 0.5 and 3 Hz. Next, a convolution of a 2 Hz sinewave (representing a template for a gait cycle) is performed, from which local maxima will be detected to define the regions of gait acc_v: vertical acceleration acc_ap: anterior–posterior acceleration WinS = 3 s; window size for convolution OL = 1.5 s; overlap of windows Activity_thresh = 0.01; Motion threshold Fs: sampling frequency Start: beginning of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector End: termination of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector Matlab\uae Iluz, Gazit [40] GSDB This algorithm, based on a time domain-approach, detects the gait periods based on identified steps. First, the norm of triaxial acceleration signal is low-pass filtered (FIR, fc = 3.2 Hz), then a peak detection procedure using a threshold of 0.1 [g] is applied to identify steps. Consecutive steps, detected using an adaptive step duration threshold are associated to gait sequences acc_norm: norm of the 3D-accelerometer signal Fs: sampling frequency th: peak detection threshold: 0.1 (g) Start: beginning of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector End: termination of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector Matlab\uae Paraschiv-Ionescu, Newman [41] GSDc This algorithm utilizes the same approach as GSDBthe only difference being a different threshold for peak detection of 0.15 [g] acc_norm: norm of the 3D-accelerometer signal Fs: sampling frequency th: peak detection threshold: 0.15 (g) Start: beginning of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector End: termination of N gait sequences [s] relative to the start of a recording or a test/trial. Format: 1 7 N vector Matlab\uae Paraschiv-Ionescu, Newman [41] In Discussion section, the paragraph should read as "Based on our findings collectively, we recommend using GSDB on cohorts with slower gait speeds and substantial gait impairments (e.g., proximal femoral fracture). This may be because this algorithm is based on the acceleration norm (overall accelerometry signal rather than a specific axis/direction (e.g., vertical), hence it is more robust to sensor misalignments that are common in unsupervised real-life settings. Moreover, the use of adaptive threshold, that are derived from the features of a subject’s data and applied to step duration for detection of steps belonging to gait sequences, allows increased robustness of the algorithm to irregular and unstable gait patterns" instead of “Based on our findings collectively, we recommend using GSDB on cohorts with slower gait speeds and substantial gait impairments (e.g., proximal femoral fracture). This may be because this algorithm is based on the acceleration norm (overall accelerometry signal rather than a specific axis/direction (e.g., vertical), hence it is more robust to sensor misalignments that are common in unsupervised real-life settings [41]. Moreover, the use of adaptive thresholds, that are derived from the features of a subject’s data and applied to the amplitude of acceleration norm and to step duration for detection of steps belonging to gait sequences, allows increased robustness of the algorithm to irregular and unstable gait patterns”
    • 

    corecore