322 research outputs found
Potential Harmonics Expansion Method for Trapped Interacting Bosons : Inclusion of Two-Body Correlation
We study a system of identical interacting bosons trapped by an external
field by solving ab initio the many-body Schroedinger equation. A complete
solution by using, for example, the traditional hyperspherical harmonics (HH)
basis develops serious problems due to the large degeneracy of HH basis,
symmetrization of the wave function, calculation of the matrix elements, etc.
for large . Instead of the HH basis, here we use the "potential harmonics"
(PH) basis, which is a subset of HH basis. We assume that the contribution to
the orbital and grand orbital [in -dimensional space of the reduced
motion] quantum numbers comes only from the interacting pair. This implies
inclusion of two-body correlations only and disregard of all higher-body
correlations. Such an assumption is ideally suited for the Bose-Einstein
condensate (BEC), which is extremely dilute. Unlike the hyperspherical
variables in HH basis, the PH basis involves only three {\it{active}}
variables. It drastically reduces the number of coupled equations and
calculation of the potential matrix becomes tremendously simplified, as it
involves integrals over only three variables for any . One can easily
incorporate realistic atom-atom interactions in a straight forward manner. We
study the ground and excited state properties of the condensate for both
attractive and repulsive interactions for various particle number.Comment: 36 pages, 7 included figures, plain late
Condenser-free contrast methods for transmitted-light microscopy
Phase contrast microscopy allows the study of highly transparent yet detail-rich specimens by producing intensity contrast from phase objects within the sample. Presented here is a generalized phase contrast illumination schema in which condenser optics are entirely abrogated, yielding a condenser- free yet highly effective method of obtaining phase contrast in transmitted-light microscopy. A ring of light emitting diodes (LEDs) is positioned within the light-path such that observation of the objective back focal plane places the il- luminating ring in appropriate conjunction with the phase ring. It is demonstrated that true Zernike phase contrast is obtained, whose geometry can be flexibly manipulated to provide an arbitrary working distance between illuminator and sample. Condenser-free phase contrast is demonstrated across a range of magnifications (4–100×), numerical apertures (0.13–1.65NA) and conventional phase positions. Also demonstrated is condenser-free darkfield microscopy as well as combinatorial contrast including Rheinberg illumination and simultaneous, colour-contrasted, brightfield, darkfield and Zernike phase contrast. By providing enhanced and arbitrary working space above the preparation, a range of concurrent imaging and electrophysiological techniques will be technically facilitated. Condenser-free phase contrast is demonstrated in conjunction with scanning ion conductance microscopy (SICM), using a notched ring to admit the scanned probe. The compact, versatile LED illumination schema will further lend itself to novel next-generation transmitted-light microscopy designs. The condenser-free illumination method, using rings of independent or radially-scanned emitters, may be exploited in future in other electromagnetic wavebands, including X-rays or the infrared
Precise Wavefront Correction with an Unbalanced Nulling Interferometer for Exo-Planet Imaging Coronagraphs
Very high dynamical range coronagraphs targeting direct exo-planet detection
(10^9 - 10^10 contrast) at small angular separation (few lambda/D units)
usually require an input wavefront quality on the order of ten thousandths of
wavelength RMS. We propose a novel method based on a pre-optics setup that
behaves partly as a low-efficiency coronagraph, and partly as a
high-sensitivity wavefront aberration compensator (phase and amplitude). The
combination of the two effects results in a highly accurate corrected
wavefront. First, an (intensity-) unbalanced nulling interferometer (UNI)
performs a rejection of part of the wavefront electric field. Then the
recombined output wavefront has its input aberrations magnified. Because of the
unbalanced recombination scheme, aberrations can be free of phase singular
points (zeros) and can therefore be compensated by a downstream phase and
amplitude correction (PAC) adaptive optics system, using two deformable
mirrors. In the image plane, the central star's peak intensity and the noise
level of its speckled halo are reduced by the UNI-PAC combination: the
output-corrected wavefront aberrations can be interpreted as an improved
compensation of the initial (eventually already corrected) incident wavefront
aberrations. The important conclusion is that not all the elements in the
optical setup using UNI-PAC need to reach the lambda/10000 rms surface error
quality.Comment: Accepted for publication in A&
Glasgow Coma Scale and Its Components on Admission: Are They Valuable Prognostic Tools in Acute Mixed Drug Poisoning?
Introduction. The verbal, eye, and motor components of Glasgow coma scale (GCS) may be influenced by poisoned patients' behavior in an attempted suicide. So, the values of admission GCS and its components for outcomes prediction in mixed drugs poisoning were investigated. Materials and Methods. A followup study data was performed on patients with mixed drugs poisoning. Outcomes were recorded as without complications and with complications. Discrimination was evaluated by calculating the area under the receiver operating characteristic curves (AUC). Results. There was a significant difference between the mean value of each component of GCS as well as the total GCS between patients with and without complication. Discrimination was best for GCS (AUC: 0.933 ± 0.020) and verbal (0.932 ± 0.021), followed by motor (0.911 ± 0.025), then eye (0.89 ± 0.028). Conclusions. Admission GCS and its components seem to be valuable in outcome prediction of patients with mixed drug poisoning
Proton-He elastic scattering at low energies
We present new accurate measurements of the differential cross section
and the proton analyzing power for proton-He
elastic scattering at various energies. A supersonic gas jet target has been
employed to obtain these low energy cross section measurements. The
distributions have been measured at = 0.99, 1.59,
2.24, 3.11, and 4.02 MeV. Full angular distributions of have been
measured at = 1.60, 2.25, 3.13, and 4.05 MeV. This set of
high-precision data is compared to four-body variational calculations employing
realistic nucleon-nucleon (NN) and three-nucleon (3N) interactions. For the
unpolarized cross section the agreement between the theoretical calculation and
data is good when a potential is used. The comparison between the
calculated and measured proton analyzing powers reveals discrepancies of
approximately 50% at the maximum of each distribution. This is analogous to the
existing `` Puzzle'' known for the past 20 years in nucleon-deuteron
elastic scattering.Comment: 22 pages, 9 figures, to be published in Physical Review C, corrected
reference 4
Calculation of the Alpha--Particle Ground State within the Hyperspherical Harmonic Basis
The problem of calculating the four--nucleon bound state properties for the
case of realistic two- and three-body nuclear potentials is studied using the
hyperspherical harmonic (HH) approach. A careful analysis of the convergence of
different classes of HH functions has been performed. A restricted basis is
chosen to allow for accurate estimates of the binding energy and other
properties of the 4He ground state. Results for various modern two-nucleon and
two- plus three-nucleon interactions are presented. The 4He asymptotic
normalization constants for separation in 2+2 and 1+3 clusters are also
computed.Comment: 29 pages, 4 figures, 11 tables, revtex
Remarkable enhancement in crystalline perfection, second harmonic generation efficiency, optical transparency, and laser damage threshold in potassium dihydrogen phosphate crystals by L-threonine doping
Effect of L-threonine (LT) doping on crystalline perfection, second harmonic generation (SHG) efficiency, optical transparency, and laser damage threshold (LDT) in potassium dihydrogen phosphate (KDP) crystals grown by slow evaporation solution technique (SEST) has been investigated. The influence of doping on growth rate and morphology of the grown crystals has also been studied. Powder x-ray diffraction data confirms the crystal structure of KDP and shows a systematic variation in intensity of diffraction peaks in correlation with morphology due to varying LT concentration. No extra phase formation was observed which is further confirmed by Fourier transform Raman (FT-Raman) studies. High-resolution x-ray diffraction curves indicate that crystalline perfection has been improved to a great extent at low concentrations with a maximum perfection at 1 mol % doping. At higher concentrations (5 to 10 mol %), it is slightly reduced due to excess incorporation of dopants at the interstitial sites of the crystalline matrix. LDT has been increased considerably with increase in doping concentration, whereas SHG efficiency was found to be maximum at 1 mol % in correlation with crystalline. The optical transparency for doped crystals has been increased as compared to that of pure KDP with a maximum value at 1 mol % doping
Space-Time Approach to Scattering from Many Body Systems
We present scattering from many body systems in a new light. In place of the
usual van Hove treatment, (applicable to a wide range of scattering processes
using both photons and massive particles) based on plane waves, we calculate
the scattering amplitude as a space-time integral over the scattering sample
for an incident wave characterized by its correlation function which results
from the shaping of the wave field by the apparatus. Instrument resolution
effects - seen as due to the loss of correlation caused by the path differences
in the different arms of the instrument are automatically included and analytic
forms of the resolution function for different instruments are obtained. The
intersection of the moving correlation volumes (those regions where the
correlation functions are significant) associated with the different elements
of the apparatus determines the maximum correlation lengths (times) that can be
observed in a sample, and hence, the momentum (energy) resolution of the
measurement. This geometrical picture of moving correlation volumes derived by
our technique shows how the interaction of the scatterer with the wave field
shaped by the apparatus proceeds in space and time. Matching of the correlation
volumes so as to maximize the intersection region yields a transparent,
graphical method of instrument design. PACS: 03.65.Nk, 3.80 +r, 03.75, 61.12.BComment: Latex document with 6 fig
Watching a superfluid untwist itself: Recurrence of Rabi oscillations in a Bose-Einstein condensate
The order parameter of a condensate with two internal states can continuously
distort in such a way as to remove twists that have been imposed along its
length. We observe this effect experimentally in the collapse and recurrence of
Rabi oscillations in a magnetically trapped, two-component Bose-Einstein
condensate of ^87Rb
Wideband THz time domain spectroscopy based on optical rectification and electro-optic sampling
We present an analytical model describing the full electromagnetic propagation in a THz time-domain spectroscopy (THz-TDS) system, from the THz pulses via Optical Rectification to the detection via Electro Optic-Sampling. While several investigations deal singularly with the many elements that constitute a THz-TDS, in our work we pay particular attention to the modelling of the time-frequency behaviour of all the stages which compose the experimental set-up. Therefore, our model considers the following main aspects: (i) pump beam focusing into the generation crystal; (ii) phase-matching inside both the generation and detection crystals; (iii) chromatic dispersion and absorption inside the crystals; (iv) Fabry-Perot effect; (v) diffraction outside, i.e. along the propagation, (vi) focalization and overlapping between THz and probe beams, (vii) electro-optic sampling. In order to validate our model, we report on the comparison between the simulations and the experimental data obtained from the same set-up, showing their good agreement
- …