423 research outputs found
The edge effect of specimens in abrasive wear testing
In abrasive wear testing, the specimen edges may exhibit increased wear rates. To determine the extent of edge wear, a series of tests was conducted with the crushing pin-on-disk device. The test pin was divided into two sections, separating the wear area into inner and outer pin areas. The tests were conducted with granite and quartz rocks of varying size.
The edge effect was determined as the difference of the mass loss of a specimen comprising both the inner and outer parts and the mass loss of the inner part alone scaled to the size of the combined pin area, representing a specimen without edge wear. The tests showed increased edge effect with larger rocks, depending on the mechanical strength of the abrasive material. When using only large rocks with good mechanical strength, the edge effect could be as high as 50 % of the total specimen mass loss, whereas with more fragile rocks of smaller size, the edge effect was close to 0 %
Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V
The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and
46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8),
6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are
substantially improved in precision over previous results.Comment: 9 pages, 7 figures, 5 table
Laser Spectroscopy of Niobium Fission Fragments: First Use of Optical Pumping in an Ion Beam Cooler Buncher
A new method of optical pumping in an ion beam cooler buncher has been developed to selectively enhance ionic metastable state populations. The technique permits the study of elements previously inaccessible to laser spectroscopy and has been applied here to the study of Nb. Model independent mean-square charge radii and nuclear moments have been studied for Nb to cover the region of the N=50 shell closure and N≈60 sudden onset of deformation. The increase in mean-square charge radius is observed to be less than that for Y, with a substantial degree of β softness observed before and after N=60
Mass measurements in the vicinity of the doubly-magic waiting point 56Ni
Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have
been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with
a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu,
58Cu, and 59Zn have been measured directly with a typical precision of better
than 0.7 keV and Coulomb displacement energies have been determined. The Q
values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured
directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu,
Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations,
has been improved by a factor of 37. The excitation energy of the proton
emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10)
keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has
been obtained. Except for 53Co, the mass values have been adjusted within a
network of 17 frequency ratio measurements between 13 nuclides which allowed
also a determination of the reference masses 55Co, 58Ni, and 59Cu.Comment: 14 pages, 13 figures, submitted to Phys. Rev.
Resonance ionization spectroscopy of thorium isotopes - towards a laser spectroscopic identification of the low-lying 7.6 eV isomer of Th-229
In-source resonance ionization spectroscopy was used to identify an efficient
and selective three step excitation/ionization scheme of thorium, suitable for
titanium:sapphire (Ti:sa) lasers. The measurements were carried out in
preparation of laser spectroscopic investigations for an identification of the
low-lying Th-229m isomer predicted at 7.6 +- 0.5 eV above the nuclear ground
state. Using a sample of Th-232, a multitude of optical transitions leading to
over 20 previously unknown intermediate states of even parity as well as
numerous high-lying odd parity auto-ionizing states were identified. Level
energies were determined with an accuracy of 0.06 cm-1 for intermediate and
0.15 cm-1 for auto-ionizing states. Using different excitation pathways an
assignment of total angular momenta for several energy levels was possible. One
particularly efficient ionization scheme of thorium, exhibiting saturation in
all three optical transitions, was studied in detail. For all three levels in
this scheme, the isotope shifts of the isotopes Th-228, Th-229, and Th-230
relative to Th-232 were measured. An overall efficiency including ionization,
transport and detection of 0.6 was determined, which was predominantly limited
by the transmission of the mass spectrometer ion optics
Total Absorption Spectroscopy Study of Rb Decay: A Major Contributor to Reactor Antineutrino Spectrum Shape
The antineutrino spectra measured in recent experiments at reactors are
inconsistent with calculations based on the conversion of integral beta spectra
recorded at the ILL reactor. Rb makes the dominant contribution to the
reactor spectrum in the 5-8 MeV range but its decay properties are in question.
We have studied Rb decay with total absorption spectroscopy. Previously
unobserved beta feeding was seen in the 4.5-5.5 region and the GS to GS feeding
was found to be 87.5(25)%. The impact on the reactor antineutrino spectra
calculated with the summation method is shown and discussed.Comment: 6 pages, 3 figure
Testing of the assisting software for radiologists analysing head CT images: lessons learned
Background: Assessing a plan for user testing and evaluation of the assisting software developed for radiologists.Methods: Test plan was assessed in experimental testing, where users performed reporting on head computed tomography studies with the aid of the software developed. The user testing included usability tests, questionnaires, and interviews. In addition, search relevance was assessed on the basis of user opinions.Results: The testing demonstrated weaknesses in the initial plan and enabled improvements. Results showed that the software has acceptable usability level but some minor fixes are needed before larger-scale pilot testing. The research also proved that it is possible even for radiologists with under a year's experience to perform reporting of non-obvious cases when assisted by the software developed. Due to the small number of test users, it was impossible to assess effects on diagnosis quality.Conclusions: The results of the tests performed showed that the test plan designed is useful, and answers to the key research questions should be forthcoming after testing with more radiologists. The preliminary testing revealed opportunities to improve test plan and flow, thereby illustrating that arranging preliminary test sessions prior to any complex scenarios is beneficial
- …