288 research outputs found

    Priorities for energy efficiency measures in agriculture.

    Get PDF
    This report provides a compilation of energy efficiency measures in agriculture, their opportunities and constraints to implement energy efficient agricultural systems across Europe as a result of the AGREE (Agriculture & Energy Efficiency) Coordination and Support Action funded by the 7th research framework of the EU (www.agree.aua.gr). The report dwells on earlier reports of the consortium, which listed potential energy efficiency measures (Project Deliverable 2.3: Energy Saving Measures in Agriculture – Overview on the Basis of National Reports) and identified trade-offs and win-win situations of various energy efficiency measures in agriculture (Project Deliverable 3.1: Economic and environmental analysis of energy efficiency measures in agriculture). It shows research gaps in crop production, greenhouse production, animal husbandry and system approaches, which can be regarded as priorities for energy efficiency measures in agriculture. The report is na important input for the strategic research agenda, which is one of the main outputs of the AGREE project

    Discrimination between hypervirulent and non-hypervirulent ribotypes of Clostridioides difficile by MALDI-TOF mass spectrometry and machine learning

    Get PDF
    Hypervirulent ribotypes (HVRTs) of Clostridioides difcile such as ribotype (RT) 027 are epidemiologically important. This study evaluated whether MALDI-TOF can distinguish between strains of HVRTs and non-HVRTs commonly found in Europe. Obtained spectra of clinical C. difcile isolates (training set, 157 isolates) covering epidemiologically relevant HVRTs and non-HVRTs found in Europe were used as an input for diferent machine learning (ML) models. Another 83 isolates were used as a validation set. Direct comparison of MALDI-TOF spectra obtained from HVRTs and non-HVRTs did not allow to discriminate between these two groups, while using these spectra with certain ML models could diferentiate HVRTs from non-HVRTs with an accuracy >95% and allowed for a sub-clustering of three HVRT subgroups (RT027/ RT176, RT023, RT045/078/126/127). MALDI-TOF combined with ML represents a reliable tool for rapid identifcation of major European HVRTs

    Extended Sequence Typing of Campylobacter spp., United Kingdom

    Get PDF
    Supplementing Campylobacter spp. multilocus sequence typing with nucleotide sequence typing of 3 antigen genes increased the discriminatory index achieved from 0.975 to 0.992 among 620 clinical isolates from Oxfordshire, United Kingdom. This enhanced typing scheme enabled identification of clusters and retained data required for long-range epidemiologic comparisons of isolates

    The Highly Virulent 2006 Norwegian EHEC O103:H25 Outbreak Strain Is Related to the 2011 German O104:H4 Outbreak Strain

    Get PDF
    In 2006, a severe foodborne EHEC outbreak occured in Norway. Seventeen cases were recorded and the HUS frequency was 60%. The causative strain, Esherichia coli O103:H25, is considered to be particularly virulent. Sequencing of the outbreak strain revealed resemblance to the 2011 German outbreak strain E. coli O104:H4, both in genome and Shiga toxin 2-encoding (Stx2) phage sequence. The nucleotide identity between the Stx2 phages from the Norwegian and German outbreak strains was 90%. During the 2006 outbreak, stx2-positive O103:H25 E. coli was isolated from two patients. All the other outbreak associated isolates, including all food isolates, were stx-negative, and carried a different phage replacing the Stx2 phage. This phage was of similar size to the Stx2 phage, but had a distinctive early phage region and no stx gene. The sequence of the early region of this phage was not retrieved from the bacterial host genome, and the origin of the phage is unknown. The contaminated food most likely contained a mixture of E. coli O103:H25 cells with either one of the phages

    Identification of Brucella by MALDI-TOF Mass Spectrometry. Fast and Reliable Identification from Agar Plates and Blood Cultures

    Get PDF
    BACKGROUND: MALDI-TOF mass spectrometry (MS) is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany) and their usefulness for identifying brucellae from culture plates and blood cultures. METHODOLOGY/PRINCIPAL FINDINGS: We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis), and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. CONCLUSIONS/SIGNIFICANCE: MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles

    Shiga Toxin-Mediated Hemolytic Uremic Syndrome: Time to Change the Diagnostic Paradigm?

    Get PDF
    Hemolytic uremic syndrome (HUS) is caused by enterohemorrhagic Escherichia coli (EHEC) which possess genes encoding Shiga toxin (stx), the major virulence factor, and adhesin intimin (eae). However, the frequency of stx-negative/eae-positive E. coli in stools of HUS patients and the clinical significance of such strains are unknown.Between 1996 and 2006, we sought stx-negative/eae-positive E. coli in stools of HUS patients using colony blot hybridization with the eae probe and compared the isolates to EHEC causing HUS. stx-negative/eae-positive E. coli were isolated as the only pathogens from stools of 43 (5.5%) of 787 HUS patients; additional 440 (55.9%) patients excreted EHEC. The majority (90.7%) of the stx-negative/eae-positive isolates belonged to serotypes O26:H11/NM (nonmotile), O103:H2/NM, O145:H28/NM, and O157:H7/NM, which were also the most frequent serotypes identified among EHEC. The stx-negative isolates shared non-stx virulence and fitness genes with EHEC of the corresponding serotypes and clustered with them into the same clonal complexes in multilocus sequence typing, demonstrating their close relatedness to EHEC.At the time of microbiological analysis, approximately 5% of HUS patients shed no longer the causative EHEC, but do excrete stx-negative derivatives of EHEC that lost stx during infection. In such patients, the EHEC etiology of HUS is missed using current methods detecting solely stx or Shiga toxin; this can hamper epidemiological investigations and lead to inappropriate clinical management. While maintaining the paradigm that HUS is triggered by Shiga toxin, our data demonstrate the necessity of considering genetic changes of the pathogen during infection to adapt appropriately diagnostic strategies

    Multicenter evaluation of the vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of gram-positive aerobic bacteria

    Get PDF
    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 system (bioMérieux, Inc.) for the identification of aerobic Gram-positive bacteria. A total of 1,146 unique isolates, representing 13 genera and 42 species, were analyzed, and results were compared to those obtained by nucleic acid sequence-based identification as the reference method. For 1,063 of 1,146 isolates (92.8%), the Vitek MS provided a single identification that was accurate to the species level. For an additional 31 isolates (2.7%), multiple possible identifications were provided, all correct at the genus level. Mixed-genus or single-choice incorrect identifications were provided for 18 isolates (1.6%). Although no identification was obtained for 33 isolates (2.9%), there was no specific bacterial species for which the Vitek MS consistently failed to provide identification. In a subset of 463 isolates representing commonly encountered important pathogens, 95% were accurately identified to the species level and there were no misidentifications. Also, in all but one instance, the Vitek MS correctly differentiated Streptococcus pneumoniae from other viridans group streptococci. The findings demonstrate that the Vitek MS system is highly accurate for the identification of Gram-positive aerobic bacteria in the clinical laboratory setting

    The Staphylococcus aureus Peptidoglycan Protects Mice against the Pathogen and Eradicates Experimentally Induced Infection

    Get PDF
    Staphylococcus aureus, in spite of antibiotics, is still a major human pathogen causing a wide range of infections. The present study describes the new vaccine A170PG, a peptidoglycan-based vaccine. In a mouse model of infection, A170PG protects mice against a lethal dose of S. aureus. Protection lasts at least 40 weeks and correlates with increased survival and reduced colonization. Protection extends into drug-resistant (MRSA or VISA) and genetically diverse clinical strains. The vaccine is effective when administered - in a single dose and without adjuvant - by the intramuscular, intravenous or the aerosol routes and induces active as well as passive immunization. Of note, A170PG also displays therapeutic activity, eradicating staphylococci, even when infection is systemic. Sustained antibacterial activity and induction of a strong and rapid anti-inflammatory response are the mechanisms conferring therapeutic efficacy to A170PG
    corecore