5,947 research outputs found

    Concept study of a UV coronagraph spectrometer for the pinhole-occulter facility

    Get PDF
    The results of a very short study to define an Ultraviolet Coronagraph-Spectrometer (UVCS) for the Pinhole/Occulter Facility (P/OF) are summarized. The P/OF instrument was based on docummentation from the Definition Phase of the Spacelab Coronographs Program which was effectively completed in August 1980. The primary differences between the P/OF instrument and the Spacelab experiment are the remote occulter mask, the telescope size , and the deployable structure to accommodate P/OF's length restrictions. Requirement for P/OF that are associated with these features are briefly considered, but further study is need to more fully consider the unusual implications, particularly in the interplay between the instrument pointing and the P/OF boom control

    Sodium sulfate: Vaporization thermodynamics and role in corrosive flames

    Get PDF
    Gaseous species over liquid Na2SO4 were identified by the technique of molecular beam mass spectrometry. The heat and entropy of vaporization of the Na2SO4 molecule were measured directly. Comparisons of the experimental entropy with values calculated using various molecular parameters were used to estimate the molecular structure and vibrational frequencies. The thermodynamic properties of gaseous and condensed phase Na2SO4, along with additional pertinent species, were used in a computer program to calculate equilibrium flame compositions and temperatures for representative turbine engine and burner rig flames. Compositions were calculated at various fuel-to-oxidant ratios with additions of sulfur to the fuel and the components of sea salt to the intake air. Temperatures for condensation of Na2SO4 were obtained as a function of sulfur and sea salt concentrations

    Preliminary evaluation of the role of K2S in MHD hot stream seed recovery

    Get PDF
    Results are presented for recent analytical and experimental studies of the role of K2S in MHD hot stream seed recovery. The existing thermodynamic data base was found to contain large uncertainties and to be nonexistent for vapor phase K2S. Knudsen cell mass spectrometric experiments were undertaken to determine the vapor species in equilibrium with K2S(c). K atoms and S2 molecules ere found to be the major vapor phase species in vacuum, accounting for greater than 99 percent of the vapor phase. Combustion gas deposition studies using No. 2 Diesel fuel were also undertaken and revealed that condensed phase K2SO3 may potentially be an important compound in the MHD stream at near-stoichiometric combustion

    Computer assisted performance tests of the Lyman Alpha Coronagraph

    Get PDF
    Preflight calibration and performance tests of the Lyman Alpha Coronagraph rocket instrument in the laboratory, with the experiment in its flight configuration and illumination levels near those expected during flight were successfully carried out using a pulse code modulation telemetry system simulator interfaced in real time to a PDP 11/10 computer system. Post acquisition data reduction programs developed and implemented on the same computer system aided in the interpretation of test and calibration data

    High-temperature mass spectrometry - Vaporization of group 4-B metal carbides

    Get PDF
    The high temperature vaporization of the metal-carbon systems TiC, ZrC, HfC, and ThC was studied by the Knudsen effusion - mass spectrometric method. For each system the metal dicarbide and tetracarbide molecular species were identified in the gas phase. Relative ion currents of the carbides and metals were measured as a function of temperature. Second- and third-law methods were used to determine enthalpies. Maximum values were established for the dissociation energies of the metal monocarbide molecules TiC, ZrC, HfC, and ThC. Thermodynamic functions used in the calculations are discussed in terms of assumed molecular structures and electronic contributions to the partition functions. The trends shown by the dissociation energies of the carbides of Group 4B are compared with those of neighboring groups and discussed in relation to the corresponding oxides and chemical bonding. The high temperature molecular beam inlet system and double focusing mass spectrometer are described

    Thermodynamics and kinetics of the sulfation of porous calcium silicate

    Get PDF
    The sulfation of plasma sprayed calcium silicate in flowing SO2/air mixtures at 900 and 1000 C was investigated thermogravimetrically. Reaction products were analyzed using electron microprobe and X-ray diffraction analysis techniques, and results were compared with thermodynamic predictions. The percentage, by volume, of SO2 in air was varied between 0.036 and 10 percent. At 10 percent SO2 the weight gain curve displays a concave downward shoulder early in the sulfation process. An analytical model was developed which treats the initial process as one which decays exponentially with increasing time and the subsequent process as one which decays exponentially with increasing weight gain. At lower SO2 levels the initial rate is controlled by the reactant flow rate. At 1100 C and 0.036 percent SO2 there is no reaction, in agreement with thermodynamic predictions

    The role of NaCl in flame chemistry, in the deposition process, and in its reactions with protective oxides as related to hot corrosion

    Get PDF
    Sodium chloride is believed to be the primary source of turbine engine contamination that contributes to hot corrosion. The behavior of NaCl-containing aerosols ingested with turbine intake air is very complex; some of the NaCl may vaporize during combustion while some may remain as particulates. The NaCl can lead to Na2SO4 formation by several possible routes or it can contribute to corrosion directly. Hydrogen or oxygen atom reaction with NaCl(c) was shown to result in the release of Na(g). Gaseous NaCl in flames can be partially converted to gaseous Na2SO4 by homogeneous reactions. The remaining gaseous NaCl and other Na-containing molecules can act as sodium carriers for condensate deposition of Na2SO4 on cool surfaces. A frozen boundary layer theory was developed to predict the rates of deposition. The condensed phase NaCl can be converted directly to condensed Na2SO4 by reaction with sulfur oxides and O2. Reaction of gaseous NaCl with Cr2O3 results in the vapor phase transport of chromium by the formation of complex Cr-containing gaseous molecules. Similar gaseous complexes are formed with molybdenum. The presence of gaseous NaCl was shown to affect the oxidation kinetics of Ni-Cr alloys. It also causes changes in the surface morphology of Al2O3 scales formed on Al-containing alloys

    Computer programs for the interpretation of low resolution mass spectra: Program for calculation of molecular isotopic distribution and program for assignment of molecular formulas

    Get PDF
    Two FORTRAN computer programs for the interpretation of low resolution mass spectra were prepared and tested. One is for the calculation of the molecular isotopic distribution of any species from stored elemental distributions. The program requires only the input of the molecular formula and was designed for compatability with any computer system. The other program is for the determination of all possible combinations of atoms (and radicals) which may form an ion having a particular integer mass. It also uses a simplified input scheme and was designed for compatability with any system

    The dissociation energy of gaseous titanium mononitride

    Get PDF
    Dissociation energy of gaseous titanium nitrid

    Using high resolution displays for high resolution cardiac data

    Get PDF
    The ability to perform fast, accurate, high resolution visualization is fundamental to improving our understanding of anatomical data. As the volumes of data increase from improvements in scanning technology, the methods applied to rendering and visualization must evolve. In this paper we address the interactive display of data from high resolution MRI scanning of a rabbit heart and subsequent histological imaging. We describe a visualization environment involving a tiled LCD panel display wall and associated software which provide an interactive and intuitive user interface. The oView software is an OpenGL application which is written for the VRJuggler environment. This environment abstracts displays and devices away from the application itself, aiding portability between different systems, from desktop PCs to multi-tiled display walls. Portability between display walls has been demonstrated through its use on walls at both Leeds and Oxford Universities. We discuss important factors to be considered for interactive 2D display of large 3D datasets, including the use of intuitive input devices and level of detail aspects
    corecore