52 research outputs found

    Ultrahigh step-up dc-dc converter for distributed generation by three Degrees of Freedom (3DoF) approach

    Get PDF
    This paper proposes a novel dc-dc converter topology to achieve an ultrahigh step-up ratio while maintaining a high conversion efficiency. It adopts a three degree of freedom approach in the circuit design. It also demonstrates the flexibility of the proposed converter to combine with the features of modularity, electrical isolation, soft-switching, low voltage stress on switching devices, and is thus considered to be an improved topology over traditional dc-dc converters. New control strategies including the two-section output voltage control and cell idle control are also developed to improve the converter performance. With the cell idle control, the secondary winding inductance of the idle module is bypassed to decrease its power loss. A 400-W dc-dc converter is prototyped and tested to verify the proposed techniques, in addition to a simulation study. The step-up conversion ratio can reach 1:14 with a peak efficiency of 94% and the proposed techniques can be applied to a wide range of high voltage and high power distributed generation and dc power transmission

    Online two-section PV array fault diagnosis with optimized voltage sensor locations

    Get PDF
    Photovoltaic (PV) stations have been widely built in the world to utilize solar energy directly. In order to reduce the capital and operational costs, early fault diagnosis is playing an increasingly important role by enabling the long effective operation of PV arrays. This paper analyzes the terminal characteristics of faulty PV strings and arrays, and it develops a PV array fault diagnosis technique. The terminal current-voltage curve of a faulty PV array is divided into two sections, i.e., high-voltage and low-voltage fault diagnosis sections. The corresponding working points of healthy string modules and of healthy and faulty modules in an unhealthy string are then analyzed for each section. By probing into different working points, a faulty PV module can be located. The fault information is of critical importance for the maximum power point tracking and the array dynamical reconfiguration. Furthermore, the string current sensors can be eliminated, and the number of voltage sensors can be reduced by optimizing voltage sensor locations. Typical fault scenarios including monostring, multistring, and a partial shadow for a 1.6-kW 3 timestimes 3 PV array are presented and experimentally tested to confirm the effectiveness of the proposed fault diagnosis method

    The endogenous hydrogen sulfide producing enzyme cystathionine-β synthase contributes to visceral hypersensitivity in a rat model of irritable bowel syndrome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The pathogenesis of visceral hypersensitivity, a characteristic pathophysiological feature of irritable bowel syndrome (IBS), remains elusive. Recent studies suggest a role for hydrogen sulfide (H<sub>2</sub>S) in pain signaling but this has not been well studied in visceral models of hyperalgesia. We therefore determined the role for the endogenous H<sub>2</sub>S producing enzyme cystathionine-β-synthetase (CBS) in a validated rat model of IBS-like chronic visceral hyperalgesia (CVH). CVH was induced by colonic injection of 0.5% acetic acid (AA) in 10-day-old rats and experiments were performed at 8–10 weeks of age. Dorsal root ganglion (DRG) neurons innervating the colon were labeled by injection of DiI (1,1'-dioleyl-3,3,3',3-tetramethylindocarbocyanine methanesulfonate) into the colon wall.</p> <p>Results</p> <p>In rat DRG, CBS-immunoreactivity was observed in approximately 85% of predominantly small- and medium-sized neurons. Colon specific DRG neurons revealed by retrograde labeling DiI were all CBS-positive. CBS-positive colon neurons co-expressed TRPV1 or P2X3 receptors. Western blotting analysis showed that CBS expression was significantly increased in colon DRGs 8 weeks after neonatal AA-treatment. Furthermore, the CBS inhibitor hydroxylamine markedly attenuated the abdominal withdrawal reflex scores in response to colorectal distention in rats with CVH. By contrast, the H<sub>2</sub>S donor NaHS significantly enhanced the frequency of action potentials of colon specific DRG neurons evoked by 2 times rheobase electrical stimulation.</p> <p>Conclusion</p> <p>Our results suggest that upregulation of CBS expression in colonic DRG neurons and H<sub>2</sub>S signaling may play an important role in developing CVH, thus identifying a specific neurobiological target for the treatment of CVH in functional bowel syndromes.</p

    Effects and mechanisms of auricular electroacupuncture on gastric hypersensitivity in a rodent model of functional dyspepsia

    Get PDF
    Background Functional dyspepsia (FD) is a common functional gastrointestinal disease, and abdominal pain is one of the main symptoms. The aim of this study was to explore the effects and mechanisms of auricular electro-acupuncture (AEA) on gastric hypersensitivity in a rodent model of FD. Methods Ten-day-old pups were gavaged with 0.2 ml of 0.1% iodoacetamide daily for 6 days. AEA at the “stomach” point with different parameters or sham-EA was performed on 8-week-old animals. Gastric sensitivity to gastric distention was measured under different conditions. Autonomic functions were assessed from the spectral analysis of heart rate variability (HRV) derived from the electrocardiogram. Naloxone was injected intraperitoneally before AEA to explore the opioid mechanism. Gastric emptying was measured at the end of the study. Results 1) Gastric sensitivity to gastric distention was higher in the FD rats. AEA with parameters of 0.1s on, 0.4s off, 100Hz, 0.3ms and 0.4–0.5mA, but not other parameters or sham-EA, decreased gastric hypersensitivity in the FD rats. Naloxone did not block the effect of AEA. 2) Lower vagal activity and higher sympathovagal ratio were noted in the FD rats, compared with the controls. AEA increased vagal activity and improved sympathovagal imbalance. Conclusions AEA ameliorates gastric hypersensitivity in FD rats and this effect may be attributed to the improvement of sympathovagal balance.Yeshttp://www.plosone.org/static/editorial#pee

    The rumination syndrome: Clinical and manometric profile, therapy, and long-term outcome

    No full text
    The aims of this study were to investigate the diagnostic studies necessary to identify rumination syndrome and the long-term therapeutic outcomes of patients with rumination syndrome. Sixteen patients with rumination were evaluated between 1989 and 1995. Esophageal motility, gastric emptying, upper gastrointestinal motility, and electrogastrography of all patients were reviewed; follow-up information about their current status was available from 10 of the 16 patients. Duration of symptoms was 77.2 months and the mean age was 28.5 years at the time of diagnosis. Esophageal and upper gastrointestinal motility, gastric emptying, and electrogastrographic studies were all normal. Mean lower esophageal pressure was 12.7 mm Hg and three of the 16 patients had a decreased pressure of less than 6 mm Hg. Ten patients were followed for a mean duration of 31.2 months. Five of 10 patients used biofeedback and relaxation techniques and reported subjective improvement. Our results indicate that rumination syndrome is often confused with a gastric motility disorder and diagnosis is possible if one is aware of this condition. Although there is not a definitive management protocol for this condition, reassurance and education of the patient and the family are crucial first steps followed by behavioral and relaxation programs

    A Layered Organic Cathode for High-Energy, Fast-Charging, and Long-Lasting Li-Ion Batteries

    No full text
    Eliminating the use of critical metals in cathode materials can accelerate global adoption of rechargeable lithium-ion batteries. Organic cathode materials, derived entirely from earth-abundant elements, are in principle ideal alternatives but have not yet challenged inorganic cathodes due to poor conductivity, low practical storage capacity, or poor cyclability. Here, we describe a layered organic electrode material whose high electrical conductivity, high storage capacity, and complete insolubility enable reversible intercalation of Li+ ions, allowing it to compete at the electrode level, in all relevant metrics, with inorganic-based lithium-ion battery cathodes. Our optimized cathode stores 306 mAh g–1cathode, delivers an energy density of 765 Wh kg–1cathode, higher than most cobalt-based cathodes, and can charge–discharge in as little as 6 min. These results demonstrate the operational competitiveness of sustainable organic electrode materials in practical batteries
    • …
    corecore