199 research outputs found

    Self-Management Support Using a Digital Health System Compared With Usual Care for Chronic Obstructive Pulmonary Disease:Randomized Controlled Trial

    Get PDF
    BACKGROUND: We conducted a randomized controlled trial of a digital health system supporting clinical care through monitoring and self-management support in community-based patients with moderate to very severe chronic obstructive pulmonary disease (COPD). OBJECTIVE: The aim of this study was to determine the efficacy of a fully automated Internet-linked, tablet computer-based system of monitoring and self-management support (EDGE' sElf-management anD support proGrammE) in improving quality of life and clinical outcomes. METHODS: We compared daily use of EDGE with usual care for 12 months. The primary outcome was COPD-specific health status measured with the St George's Respiratory Questionnaire for COPD (SGRQ-C). RESULTS: A total of 166 patients were randomized (110 EDGE, 56 usual care). All patients were included in an intention to treat analysis. The estimated difference in SGRQ-C at 12 months (EDGE-usual care) was -1.7 with a 95% CI of -6.6 to 3.2 (P=.49). The relative risk of hospital admission for EDGE was 0.83 (0.56-1.24, P=.37) compared with usual care. Generic health status (EQ-5D, EuroQol 5-Dimension Questionnaire) between the groups differed significantly with better health status for the EDGE group (0.076, 95% CI 0.008-0.14, P=.03). The median number of visits to general practitioners for EDGE versus usual care were 4 versus 5.5 (P=.06) and to practice nurses were 1.5 versus 2.5 (P=.03), respectively. CONCLUSIONS: The EDGE clinical trial does not provide evidence for an effect on COPD-specific health status in comparison with usual care, despite uptake of the intervention. However, there appears to be an overall benefit in generic health status; and the effect sizes for improved depression score, reductions in hospital admissions, and general practice visits warrants further evaluation and could make an important contribution to supporting people with COPD. TRIAL REGISTRATION: International Standard Randomized Controlled Trial Number (ISRCTN): 40367841; http://www.isrctn.com/ISRCTN40367841 (Archived by WebCite at http://www.webcitation.org/6pmfIJ9KK)

    Successful awake proning is associated with improved clinical outcomes in patients with COVID-19: single-centre high-dependency unit experience

    Get PDF
    The SARS-CoV-2 can lead to severe illness with COVID-19. Outcomes of patients requiring mechanical ventilation are poor. Awake proning in COVID-19 improves oxygenation, but on data clinical outcomes is limited. This single-centre retrospective study aimed to assess whether successful awake proning of patients with COVID-19, requiring respiratory support (continuous positive airways pressure (CPAP) or high-flow nasal oxygen (HFNO)) on a respiratory high-dependency unit (HDU), is associated with improved outcomes. HDU care included awake proning by respiratory physiotherapists. Of 565 patients admitted with COVID-19, 71 (12.6%) were managed on the respiratory HDU, with 48 of these (67.6%) requiring respiratory support. Patients managed with CPAP alone 22/48 (45.8%) were significantly less likely to die than patients who required transfer onto HFNO 26/48 (54.2%): CPAP mortality 36.4%; HFNO mortality 69.2%, (p=0.023); however, multivariate analysis demonstrated that increasing age and the inability to awake prone were the only independent predictors of COVID-19 mortality. The mortality of patients with COVID-19 requiring respiratory support is considerable. Data from our cohort managed on HDU show that CPAP and awake proning are possible in a selected population of COVID-19, and may be useful. Further prospective studies are required

    British Thoracic Society quality standards for home oxygen use in adults.

    Get PDF
    The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for home oxygen provision in the UK, together with measurable markers of good practice. Quality statements are based on the British Thoracic Society (BTS) Guideline for Home Oxygen Use in Adults.This article is freely available via Open Access. Click on the Additional Link above to access the full-text via the publisher's site

    Dislocation of total hip replacement in patients with fractures of the femoral neck: A prospective cohort study of 713 consecutive hips

    Get PDF
    Background Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach

    Assessing Fish and Motile Fauna around Offshore Windfarms Using Stereo Baited Video

    Get PDF
    There remains limited knowledge of how offshore windfarm developments influence fish assemblages, particularly at a local scale around the turbine structures. Considering the existing levels of anthropogenic pressures on coastal fish populations it is becoming increasingly important for developers and environmental regulators to gain a more comprehensive understanding of the factors influencing fish assemblages. Improving our ability to assess such fish populations in close proximity to structures will assist in increasing this knowledge. In the present study we provide the first trial use of Baited Remote Underwater Stereo-Video systems (stereo BRUVs) for the quantification of motile fauna in close proximity to offshore wind turbines. The study was conducted in the Irish Sea and finds the technique to be a viable means of assessing the motile fauna of such environments. The present study found a mixture of species including bottom dwellers, motile crustaceans and large predatory fish. The majority of taxa observed were found to be immature individuals with few adult individuals recorded. The most abundant species were the angular crab (Goneplax rhomboides) and the small-spotted catshark (Scyliorhinus canicula). Of note in this study was the generally low abundance and diversity of taxa recorded across all samples, we hypothesise that this reflects the generally poor state of the local fauna of the Irish Sea. The faunal assemblages sampled in close proximity to turbines were observed to alter with increasing distance from the structure, species more characteristic of hard bottom environments were in abundance at the turbines (e.g. Homarus gammarus, Cancer pagarus, Scyliorhinus spp.) and those further away more characteristic of soft bottoms (e.g. Norwegian Lobster). This study highlights the need for the environmental impacts of offshore renewables on motile fauna to be assessed using targeted and appropriate tools. Stereo BRUVs provide one of those tools, but like the majority of methods for sampling marine biota, they have limitations. We conclude our paper by providing a discussion of the benefits and limitations of using this BRUV technique for assessing fauna within areas close to offshore windfarms

    Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head

    Get PDF
    BACKGROUND: Ceramic bearings in total hip arthroplasty (THA) have been introduced in clinical practice to minimize the problem of polyethylene particle-induced osteolysis. The aim of the study is to report the results of 68 consecutive alumina-on-alumina THAs done in 61 patients for avascular necrosis (AVN) of the femoral head. MATERIALS AND METHODS: In all implants a press-fit cup was used; it was combined with a 32-mm alumina head and with titanium-alloy stems. The mean age at surgery was 50 years. At an average follow-up of 13 years two hips have been revised, one for periprosthetic infection and one for excessive abduction of the cup. RESULTS: No revision for aseptic loosening is recorded; one anatomical cementless femoral stem had radiological evidence of definite aseptic loosening. No dislocations occurred, and no osteolysis was observed. CONCLUSIONS: The results support the application of alumina-alumina THA for long-lasting replacements

    VarLOCK - sequencing independent, rapid detection of SARS-CoV-2 variants of concern for point-of-care testing, qPCR pipelines and national wastewater surveillance

    Get PDF
    The COVID-19 pandemic continues to pose a threat to the general population. The ongoing vaccination programs provide protection to individuals and facilitate the opening of society and a return to normality. However, emergent and existing SARS-CoV-2 variants capable of evading the immune system endanger the efficacy of the vaccination strategy. To preserve the efficacy of SARS-CoV-2 vaccination globally, aggressive and effective surveillance for known and emerging SARS-CoV-2 Variants of Concern (VOC) is required. Rapid and specific molecular diagnostics can provide speed and coverage advantages compared to genomic sequencing alone, benefitting the public health response and facilitating VOC containment. In this work, we expand the recently developed SARS-CoV-2 CRISPR-Cas detection technology (SHERLOCK) to allow rapid and sensitive discrimination of VOCs, that can be used at point of care and/or implemented in the pipelines of small or large testing facilities, and even determine proportion of VOCs in pooled population-level wastewater samples. This technology aims to complement the ongoing sequencing efforts to allow facile and, crucially, rapid identification of individuals infected with VOCs to help break infection chains. Here, we show the optimisation of our VarLOCK assays (Variant-specific SHERLOCK) for multiple specific mutations in the S gene of SARS-CoV-2 and validation with samples from the Cardiff University Testing Service. We also show the applicability of VarLOCK to national wastewater surveillance of SARS-CoV-2 variants. In addition, we show the rapid adaptability of the technique for new and emerging VOCs such as Omicron
    corecore