252 research outputs found

    ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

    Get PDF
    The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data

    Effects of environmental exposure on cryogenic thermal insulation materials

    Get PDF
    Investigation was made to optimize selection of insulation materials for reusable space vehicles which will be repeatedly operated over periods of up to ten years. Results of study are summarized in two reports. Volume I describes tests and significant findings. In Volume II, extensive test data obtained are organized in handbook form

    Physiological changes after fluid bolus therapy in sepsis: a systematic review of contemporary data

    Get PDF
    Fluid bolus therapy (FBT) is a standard of care in the management of the septic, hypotensive, tachycardic and/or oliguric patient. However, contemporary evidence for FBT improving patient-centred outcomes is scant. Moreover, its physiological effects in contemporary ICU environments and populations are poorly understood. Using three electronic databases, we identified all studies describing FBT between January 2010 and December 2013. We found 33 studies describing 41 boluses. No randomised controlled trials compared FBT with alternative interventions, such as vasopressors. The median fluid bolus was 500 ml (range 100 to 1,000 ml) administered over 30 minutes (range 10 to 60 minutes) and the most commonly administered fluid was 0.9% sodium chloride solution. In 19 studies, a predetermined physiological trigger initiated FBT. Although 17 studies describe the temporal course of physiological changes after FBT in 31 patient groups, only three studies describe the physiological changes at 60 minutes, and only one study beyond this point. No studies related the physiological changes after FBT with clinically relevant outcomes. There is a clear need for at least obtaining randomised controlled evidence for the physiological effects of FBT in patients with severe sepsis and septic shock beyond the period immediately after its administration

    Summary [January 1978]

    Get PDF
    This brief provides a summary of the world, UK and Scottish economic outlook. The upward movement in the Scotland/UK unemployment relative over the past few quarters is unlikely to portend a return to the poor relative performance of the Scottish economy which occurred in the early nineteen sixties. Nevertheless the outlook for the Scottish economy in 1978 is not very encouraging

    CrO2: a self-doped double exchange ferromagnet

    Full text link
    Band structure calculations of CrO2 carried out in the LSDA+U approach reveal a clear picture of the physics behind the metallic ferromagnetic properties. Arguments are presented that the metallic ferromagnetic oxide CrO2 belongs to a class of materials in which magnetic ordering exists due to double exchange (in this respect CrO2 turns out to be similar to the CMR manganates). It is concluded that CrO2 has small or even negative charge transfer gap which can result in self-doping. Certain experiments to check the proposed picture are suggested.Comment: 4 pages, 4 Figure

    Ground-state properties of rutile: electron-correlation effects

    Full text link
    Electron-correlation effects on cohesive energy, lattice constant and bulk compressibility of rutile are calculated using an ab-initio scheme. A competition between the two groups of partially covalent Ti-O bonds is the reason that the correlation energy does not change linearly with deviations from the equilibrium geometry, but is dominated by quadratic terms instead. As a consequence, the Hartree-Fock lattice constants are close to the experimental ones, while the compressibility is strongly renormalized by electronic correlations.Comment: 1 figure to appear in Phys. Rev.

    Acute kidney injury in sepsis

    Get PDF
    Acute kidney injury (AKI) and sepsis carry consensus definitions. The simultaneous presence of both identifies septic AKI. Septic AKI is the most common AKI syndrome in ICU and accounts for approximately half of all such AKI. Its pathophysiology remains poorly understood, but animal models and lack of histological changes suggest that, at least initially, septic AKI may be a functional phenomenon with combined microvascular shunting and tubular cell stress. The diagnosis remains based on clinical assessment and measurement of urinary output and serum creatinine. However, multiple biomarkers and especially cell cycle arrest biomarkers are gaining acceptance. Prevention of septic AKI remains based on the treatment of sepsis and on early resuscitation. Such resuscitation relies on the judicious use of both fluids and vasoactive drugs. In particular, there is strong evidence that starch-containing fluids are nephrotoxic and decrease renal function and suggestive evidence that chloride-rich fluid may also adversely affect renal function. Vasoactive drugs have variable effects on renal function in septic AKI. At this time, norepinephrine is the dominant agent, but vasopressin may also have a role. Despite supportive therapies, renal function may be temporarily or completely lost. In such patients, renal replacement therapy (RRT) becomes necessary. The optimal intensity of this therapy has been established, while the timing of when to commence RRT is now a focus of investigation. If sepsis resolves, the majority of patients recover renal function. Yet, even a single episode of septic AKI is associated with increased subsequent risk of chronic kidney disease.Peer reviewe
    corecore