3,397 research outputs found

    A Catalog of Digital Images of 113 Nearby Galaxies

    Get PDF
    We present a digital catalog of images of 113 galaxies in this paper. These galaxies are all nearby, bright, large and well resolved. All images were recorded with charge coupled devices (CCDs) at the Palomar Observatory with the 1.5 meter telescope and at the Lowell Observatory with the 1.1 meter telescope. At Palomar we used the Thuan--Gunn g, r and i photometric bands to take 3 images each of 31 spiral galaxies; at Lowell we used the B_J and R bands (2 images per galaxy) of the photometric system by Gullixson et al. (1995) to observe 82 spirals and ellipticals. The galaxies were selected to span the Hubble classification classes. All data are photometrically calibrated with foreground stars removed. Important data on these galaxies published in the "Third Reference Catalog of Bright Galaxies" (RC3) are recorded in the FITS file headers. All files are available through anonymous FTP from ftp://astro.princeton.edu/, through WWW at http://astro.princeton.edu/~frei/galaxy_catalog.html, and Princeton University Press will soon publish the data on CD-ROM.Comment: uuencoded compressed tar archive of postscript files (paper + 2 tables + 7 figures) Accepted for publication in the Astronomical Journa

    TAER Wind Conversion program /TARWON/ user's manual

    Get PDF
    Computer program for reducing radar tracking data magnetic tape numbers for data storage by editing and low pass filterin

    Association of inferior vena cava filter placement for venous thromboembolic disease and a contraindication to anticoagulation with 30-day mortality

    Get PDF
    Importance: Despite the absence of data from randomized clinical trials, professional societies recommend inferior vena cava (IVC) filters for patients with venous thromboembolic disease (VTE) and a contraindication to anticoagulation therapy. Prior observational studies of IVC filters have suggested a mortality benefit associated with IVC filter insertion but have often failed to adjust for immortal time bias, which is the time before IVC filter insertion, during which death can only occur in the control group. Objective: To determine the association of IVC filter placement with 30-day mortality after adjustment for immortal time bias. Design, Setting, and Participants: This comparative effectiveness, retrospective cohort study used a population-based sample of hospitalized patients with VTE and a contraindication to anticoagulation using the State Inpatient Database and the State Emergency Department Database, part of the Healthcare Cost and Utilization Project of the Agency for Healthcare Research and Quality, from hospitals in California (January 1, 2005, to December 31, 2011), Florida (January 1, 2005, to December 31, 2013), and New York (January 1, 2005, to December 31, 2012). Data analysis was conducted from September 15, 2015, to March 14, 2018. Exposure: Inferior vena cava filter placement. Main Outcomes and Measures: Multivariable Cox proportional hazard models were constructed with IVC filters as a time-dependent variable that adjusts for immortal time bias. The Cox model was further adjusted using the propensity score as an adjustment variable. Results: Of 126 030 patients with VTE, 61 281 (48.6%) were male and the mean (SD) age was 66.9 (16.6) years. In this cohort, 45 771 (36.3%) were treated with an IVC filter, whereas 80 259 (63.7%) did not receive a filter. In the Cox model with IVC filter status analyzed as a time-dependent variable to account for immortal time bias, IVC filter placement was associated with a significantly increased hazard ratio of 30-day mortality (1.18; 95% CI, 1.13-1.22; P \u3c .001). When the propensity score was included in the Cox model, IVC filter placement remained associated with an increased hazard ratio of 30-day mortality (1.18; 95% CI, 1.13-1.22; P \u3c .001). Conclusions and Relevance: After adjustment for immortal time bias, IVC filter placement was associated with increased 30-day mortality in patients with VTE and a contraindication to anticoagulation. Randomized clinical trials are needed to determine the efficacy of IVC filter placement in patients with VTE and a contraindication to anticoagulation

    Extreme distributions of ground winds /3 to 150 meters/ at Cape Kennedy, Florida

    Get PDF
    Statistical analysis of wind distribution probabilities at Cape Kenned

    The Size Distribution of Trans-Neptunian Bodies

    Get PDF
    [Condensed] We search 0.02 deg^2 for trans-Neptunian objects (TNOs) with m<=29.2 (diameter ~15 km) using the ACS on HST. Three new objects are discovered, roughly 25 times fewer than expected from extrapolation of the differential sky density Sigma(m) of brighter objects. The ACS and other recent TNO surveys show departures from a power law size distribution. Division of the TNO sample into ``classical Kuiper belt'' (CKB) and ``Excited'' samples reveals that Sigma(m) differs for the two populations at 96% confidence. A double power law adequately fits all data. Implications include: The total mass of the CKB is ~0.010 M_Earth, only a few times Pluto's mass, and is predominately in the form of ~100 km bodies. The mass of Excited objects is perhaps a few times larger. The Excited class has a shallower bright-end size distribution; the largest objects, including Pluto, comprise tens of percent of the total mass whereas the largest CKBOs are only ~2% of its mass. The predicted mass of the largest Excited body is close to the Pluto mass; the largest CKBO is ~60 times less massive. The deficit of small TNOs occurs for sizes subject to disruption by present-day collisions, suggesting extensive depletion by collisions. Both accretion and erosion appearing to have proceeded to more advanced stages in the Excited class than the CKB. The absence of distant TNOs implies that any distant (60 AU) population must have less than the CKB mass in the form of objects 40 km or larger. The CKB population is sparser than theoretical estimates of the required precursor population for short period comets, but the Excited population could be a viable precursor population.Comment: Revised version accepted to the Astronomical Journal. Numerical results are very slightly revised. Implications for the origins of short-period comets are substantially revised, and tedious material on statistical tests has been collected into a new Appendi

    Discovery of a Galaxy Cluster via Weak Lensing

    Get PDF
    We report the discovery of a cluster of galaxies via its weak gravitational lensing effect on background galaxies, the first spectroscopically confirmed cluster to be discovered through its gravitational effects rather than by its electromagnetic radiation. This fundamentally different selection mechanism promises to yield mass-selected, rather than baryon or photon-selected, samples of these important cosmological probes. We have confirmed this cluster with spectroscopic redshifts of fifteen members at z=0.276, with a velocity dispersion of 615 km/s. We use the tangential shear as a function of source photometric redshift to estimate the lens redshift independently and find z_l = 0.30 +- 0.08. The good agreement with the spectroscopy indicates that the redshift evolution of the mass function may be measurable from the imaging data alone in shear-selected surveys.Comment: revised version with minor changes, to appear in ApJ

    Wide-field weak lensing by RXJ1347-1145

    Full text link
    We present an analysis of weak lensing observations for RXJ1347-1145 over a 43' X 43' field taken in B and R filters on the Blanco 4m telescope at CTIO. RXJ1347-1145 is a massive cluster at redshift z=0.45. Using a population of galaxies with 20<R<26, we detect a weak lensing signal at the p<0.0005 level, finding best-fit parameters of \sigma_v=1400^{+130}_{-140} km s^{-1} for a singular isothermal sphere model and r_{200} = 3.5^{+0.8}_{-0.2} Mpc with c = 15^{+64}_{-10} for a NFW model in an \Omega_m = 0.3, \Omega_\Lambda = 0.7 cosmology. In addition, a mass to light ratio M/L_R =90 \pm 20 M_\odot / L_{R\odot} was determined. These values are consistent with the previous weak lensing study of RXJ1347--1145 by Fischer and Tyson, 1997, giving strong evidence that systemic bias was not introduced by the relatively small field of view in that study. Our best-fit parameter values are also consistent with recent X-ray studies by Allen et al, 2002 and Ettori et al, 2001, but are not consistent with recent optical velocity dispersion measurements by Cohen and Kneib, 2002.Comment: accepted to ApJ, tentative publication 10 May 2005, v624

    LSST optical beam simulator

    Full text link
    We describe a camera beam simulator for the LSST which is capable of illuminating a 60mm field at f/1.2 with realistic astronomical scenes, enabling studies of CCD astrometric and photometric performance. The goal is to fully simulate LSST observing, in order to characterize charge transport and other features in the thick fully depleted CCDs and to probe low level systematics under realistic conditions. The automated system simulates the centrally obscured LSST beam and sky scenes, including the spectral shape of the night sky. The doubly telecentric design uses a nearly unit magnification design consisting of a spherical mirror, three BK7 lenses, and one beam-splitter window. To achieve the relatively large field the beam-splitter window is used twice. The motivation for this LSST beam test facility was driven by the need to fully characterize a new generation of thick fully-depleted CCDs, and assess their suitability for the broad range of science which is planned for LSST. Due to the fast beam illumination and the thick silicon design [each pixel is 10 microns wide and over 100 microns deep] at long wavelengths there can be effects of photon transport and charge transport in the high purity silicon. The focal surface covers a field more than sufficient for a 40x40 mm LSST CCD. Delivered optical quality meets design goals, with 50% energy within a 5 micron circle. The tests of CCD performance are briefly described.Comment: 9 pages, 9 figure

    Measuring Baryon Acoustic Oscillations with Millions of Supernovae

    Get PDF
    Since type Ia Supernovae (SNe) explode in galaxies, they can, in principle, be used as the same tracer of the large-scale structure as their hosts to measure baryon acoustic oscillations (BAOs). To realize this, one must obtain a dense integrated sampling of SNe over a large fraction of the sky, which may only be achievable photometrically with future projects such as the Large Synoptic Survey Telescope. The advantage of SN BAOs is that SNe have more uniform luminosities and more accurate photometric redshifts than galaxies, but the disadvantage is that they are transitory and hard to obtain in large number at high redshift. We find that a half-sky photometric SN survey to redshift z = 0.8 is able to measure the baryon signature in the SN spatial power spectrum. Although dark energy constraints from SN BAOs are weak, they can significantly improve the results from SN luminosity distances of the same data, and the combination of the two is no longer sensitive to cosmic microwave background priors.Comment: 4 pages, 3 figures, ApJL accepte
    • …
    corecore