19,387 research outputs found

    Morita theory and singularity categories

    Get PDF
    We propose an analogue of the bounded derived category for an augmented ring spectrum, defined in terms of a notion of Noether normalization. In many cases we show this category is independent of the chosen normalization. Based on this, we define the singularity and cosingularity categories measuring the failure of regularity and coregularity and prove they are Koszul dual in the style of the BGG correspondence. Examples of interest include Koszul algebras and Ginzburg DG-algebras, C∗(BG)C^*(BG) for finite groups (or for compact Lie groups with orientable adjoint representation), cochains in rational homotopy theory and various examples from chromatic homotopy theory.Comment: Final version, accepted for publication in Advances in Mathematics, 49 page

    Analysis of a Precambrian resonance-stabilized day length

    Get PDF
    During the Precambrian era, Earth's decelerating rotation would have passed a 21-hour period that would have been resonant with the semidiurnal atmospheric thermal tide. Near this point, the atmospheric torque would have been maximized, being comparable in magnitude but opposite in direction to the lunar torque, halting Earth's rotational deceleration, maintaining a constant day length, as detailed by Zahnle and Walker (1987). We develop a computational model to determine necessary conditions for formation and breakage of this resonant effect. Our simulations show the resonance to be resilient to atmospheric thermal noise but suggest a sudden atmospheric temperature increase like the deglaciation period following a possible "snowball Earth" near the end of the Precambrian would break this resonance; the Marinoan and Sturtian glaciations seem the most likely candidates for this event. Our model provides a simulated day length over time that resembles existing paleorotational data, though further data is needed to verify this hypothesis.Comment: 7 pages, 5 figures. Accepted for publication in Geophysical Research Letters on 10 May 201

    Recurrence rates for SIDS - the importance of risk stratification

    Get PDF
    Objective: To investigate the importance of stratification by risk factors in computing the probability of a second SIDS in a family. Design: Simulation Study Background: The fact that a baby dies suddenly and unexpectedly means that there is a raised probability that the baby’s family have risk factors associated with Sudden Infant Death Syndrome (SIDS). Thus one cannot consider the risk of a subsequent death to be that of the general population. The Confidential Enquiry into Stillbirths and Deaths in Infancy (CESDI)6 identified three major social risk factors: smoking, age1, and unemployed/unwaged as major risk factors. It gave estimates of risk for families with different numbers of these risk factors. We investigate whether it is reasonable to assume that, conditional on these risk factors, the risk of a second event is independent of the risk of the first and as a consequence one can square the risks to get the risk of two SIDS in a family. We have used CESDI data to estimate the probability of a second SID in a family under different plausible scenarios of the prevalence of the risk factors. We have applied the model to make predictions in the Care of Next Infant (CONI) study7. Results: The model gave plausible predictions. The CONI study observed 18 second SIDS. Our model predicted 14 (95% prediction interval 7 to 21). Conclusion: When considering the risk of a subsequent SIDS in a family one should always take into account the known risk factors. If all risks have been identified, then conditional on these risks, the risk of two events is the product of the individual risks However for a given family we cannot quantify the magnitude of the increased risk because of other possible risk factors not accounted for in the model

    The clinical effectiveness and cost-effectiveness of inhaler devices used in the routine management of chronic asthma in older children: a systematic review and economic evaluation

    Get PDF
    Background: This review examines the clinical effectiveness and cost-effectiveness of hand-held inhalers to deliver medication for the routine management of chronic asthma in children aged between 5 and 15 years. Asthma is a common disease of the airways, with a prevalence of treated asthma in 5–15-year-olds of around 12% and an actual prevalence in the community as high as 23%. Treatment for the condition is predominantly by inhalation of medication. There are three main types of inhaler device, pressurised metered dose, breath actuated, and dry powder, with the option of the attachment of a spacer to the first two devices under some prescribed circumstances. Two recent reviews have examined the clinical and cost-effectiveness evidence on inhaler devices, but one was for children aged under 5 years and the comparison in the second was made between pressurised metered dose inhalers and other types only. Objectives: This review examines the clinical effectiveness and cost-effectiveness of manual pressurised metered dose inhalers, breath-actuated metered dose inhalers, and breath-actuated dry powder inhalers, with and without spacers as appropriate, to deliver medication for the routine management of chronic asthma in children aged between 5 and 15 years. Methods: Two previous HTA reviews have compared the effectiveness of inhaler devices, one focusing on asthma in children aged under 5 years and the other on asthma and chronic obstructive airways disease in all age groups. For the current review, a literature search was carried out to identify all evidence relating to the use of inhalers in older children with chronic asthma. A search of in-vitro studies undertaken for one of the previous reviews was also updated. The data sources used were: 15 electronic bibliographic databases; the reference lists of one of the previous HTA reports and other relevant articles; health services research-related internet resources; and all sponsor submissions. Studies were selected according to strict inclusion and exclusion criteria, and relevant information concerning effectiveness and patient compliance and preference was extracted directly on to an extraction/evidence table. Quality assurance was monitored. Economic evaluation was undertaken by reviewing existing cost-effective evidence. Further economic modelling was carried out, and tables constructed to determine device cost-minimisation and incremental quality-adjusted life-year (QALY) thresholds between devices. Results: Number and quality of studies, and direction of evidence: Fourteen randomised controlled studies were identified relating to the clinical effectiveness of inhaler devices for delivering β2-agonists. A further five were on devices delivering corticosteroids and one concerned the delivery of cromoglicate. Overall, there were no differences in clinical efficacy between inhaler devices, but a pressurised metered dose inhaler with a spacer would appear to be more effective than one without. These findings endorse those of a previous HTA review but extend them to other inhaler devices. Seven randomised controlled trials examined the impact on clinical effectiveness of using a nonchlorofluorocarbon (CFC) propellant in place of a CFC propellant in metered dose inhalers, both pressurised and breath activated, although only one study considered the latter type. No differences were found between inhalers containing either propellant. A further 30 studies of varying quality, from 12 randomised controlled trials to non-controlled studies, were identified that concerned the impact of use by, and preference for, inhaler type, and treatment adherence in children. Differences between the studies, and limitations in comparative data between various inhaler device types, make it difficult to draw any firm conclusions from this evidence. Summary of benefits: No obvious benefits for one inhaler device type over another for use in children aged 5–15 years were identified. Costs and cost per quality-adjusted life-year: Two approaches have been taken: cost-minimisation and QALY threshold. In the QALY threshold approach, additional QALYs that each device must produce compared with a cheaper device to achieve an acceptable cost per QALY were calculated. Using the cheapest and most expensive devices for delivering 200 μg of beclometasone per day, assuming no cost offset for any device, and a threshold of £5000, the largest QALY needed was 0.00807. With such a small QALY increase, no intervention can be categorically rejected as not cost-effective. Conclusions: Generalisability of findings: On the available evidence there are no obvious benefits for one inhaler device over another when used by children aged 5–15 years with chronic asthma. However, the evidence, in the majority of cases, was compiled on children with mild to moderate asthma and restricted to a limited number of drugs. Therefore the findings may not be generalisable to those at the more severe end of the spectrum of the disease or to inhaler devices delivering some of the drugs used in the management of asthma. Need for further research: Many of the previous studies are likely to have been underpowered. Further clinical trials with a robust methodology, sufficient power and qualitative components are needed to demonstrate any differences in clinical resource use and patients’ asthma symptoms. Further studies should also include the behavioural aspects of patients towards their medication and its delivery mechanisms. It is acknowledged that sufficient power may prove impractical owing to the large numbers of patients required

    Gemini/GMOS Transmission Spectral Survey: Complete Optical Transmission Spectrum of the hot Jupiter WASP-4b

    Full text link
    We present the complete optical transmission spectrum of the hot Jupiter WASP-4b from 440-940 nm at R ~ 400-1500 obtained with the Gemini Multi-Object Spectrometers (GMOS); this is the first result from a comparative exoplanetology survey program of close-in gas giants conducted with GMOS. WASP-4b has an equilibrium temperature of 1700 K and is favorable to study in transmission due to a large scale height (370 km). We derive the transmission spectrum of WASP-4b using 4 transits observed with the MOS technique. We demonstrate repeatable results across multiple epochs with GMOS, and derive a combined transmission spectrum at a precision about twice above photon noise, which is roughly equal to to one atmospheric scale height. The transmission spectrum is well fitted with a uniform opacity as a function of wavelength. The uniform opacity and absence of a Rayleigh slope from molecular hydrogen suggest that the atmosphere is dominated by clouds with condensate grain size of ~1 um. This result is consistent with previous observations of hot Jupiters since clouds have been seen in planets with similar equilibrium temperatures to WASP-4b. We describe a custom pipeline that we have written to reduce GMOS time-series data of exoplanet transits, and present a thorough analysis of the dominant noise sources in GMOS, which primarily consist of wavelength- and time- dependent displacements of the spectra on the detector, mainly due to a lack of atmospheric dispersion correction.Comment: 23 pages, 12 figures, accepted for publication in AJ, 2017 July

    ULTRACAM photometry of the eclipsing cataclysmic variable OU Vir

    Full text link
    We present high-speed, three-colour photometry of the faint eclipsing cataclysmic variable OU Vir. For the first time in OU Vir, separate eclipses of the white dwarf and bright spot have been observed. We use timings of these eclipses to derive a purely photometric model of the system, obtaining a mass ratio of q = 0.175 +/- 0.025, an inclination of i = 79.2 +/- 0.7 degrees and a disc radius of Rd/a = 0.2315 +/- 0.0150. We separate the white dwarf eclipse from the lightcurve and, by fitting a blackbody spectrum to its flux in each passband, obtain a white dwarf temperature of T = 21700 +/- 1200 K and a distance of D = 650 +/- 210 pc. Assuming that the primary obeys the Nauenberg (1972) mass-radius relation for white dwarfs and allowing for temperature effects, we also find a primary mass Mw/Msun = 0.90 +/- 0.19, primary radius Rw/Rsun = 0.0097 +/- 0.0031 and orbital separation a/Rsun = 0.75 +/- 0.05.Comment: 8 pages LaTeX, 6 figures. Accepted by MNRAS; erratum added at end. Mon.Not.Roy.Astron.Soc. 347 (2004) 1173, erratum in pres

    New bryophyte taxon records for tropical countries 1

    Get PDF
    This is the first in a series of papers listing new records, which will be published whenever sufficient new records have been found. The taxa are arranged by countries for an easier evaluation, e.g. updates of checklists. The initials of the contributor for each record is shown in square brackets after the record, and these initials are interpreted at the end of the paper
    • …
    corecore