    How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    Get PDF
    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions

    Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths - can feeding vessels lead to misinterpretation in Doppler-detected tenosynovitis?

    Get PDF
    BACKGROUND: The aim was to investigate the presence of feeding vessels in or in close proximity to extensor and flexor tendon sheaths at the wrists level and in finger flexor tendon sheaths in healthy controls, using 3D ultrasound (US), which may cause pitfalls, in order to ensure correct interpretation of Doppler signals when diagnosing tenosynovitis. METHOD: Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger and twenty of the right wrist. US was carried out using a GE Logiq E9 unit with a 3D US probe. The colour Doppler settings were to published recommendation. RESULTS: The feeding vessels in or in close proximity to the tendon sheaths were found in the flexor and extensor tendons sheaths at least once in each participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). CONCLUSION: Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers in healthy participants. These feeding vessels can be a source of error, not only due to their presence but also because they may be interpreted as being inside the tendon sheath due to blooming and reverberations artefacts. These vessels should be taken into consideration when diagnosing Doppler tenosynovitis

    Performance of ultra-high-frequency ultrasound in the evaluation of skin involvement in systemic sclerosis: a preliminary report

    Get PDF
    High frequency ultrasound allows visualization of epidermis, dermis and hypodermis, precise measurement of skin thickness, as well as assessment of skin oedema, fibrosis and atrophy. The aim of this pilot cross-sectional observational study was to assess the performance and multiobserver variability of ultra-high-frequency (UHF) (50 MHz) ultrasound (US) in measuring skin thickness as well as the capacity of UHF-derived skin features to differentiate SSc patients from healthy controls

    The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology

    Get PDF
    Abstract BACKGROUND: In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines. OBJECTIVES: To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology. METHODS: The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures). RESULTS: Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts. CONCLUSIONS: This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted

    An international SUrvey on non-iNvaSive tecHniques to assess the mIcrocirculation in patients with RayNaud'\u80\u99s phEnomenon (SUNSHINE survey)

    No full text
    To canvas opinion concerning the role of non-invasive techniques in the assessment of patients with Raynaud's phenomenon (Rp) in clinical and research settings: four nailfold capillaroscopy methods [videocapillaroscopy (NVC), dermoscopy, stereomicroscopy, digital USB microscopy], four laser Doppler methods (laser Doppler flowmetry, imaging, anemometry/velocimetry, laser speckle contrast analysis), thermographic imaging, and upper limb arterial Doppler ultrasound. Emails with a link to the survey were sent to physicians from the European Scleroderma Trials and Research group (EUSTAR), the EULAR Study Group on Microcirculation in Rheumatic Diseases (SG_MC/RD) and members of the pediatric rheumatology Email board. The main descriptive analysis related to physicians looking after adult patients, with some analysis also of opinions from paediatric rheumatologists. 106 'adult physicians' responded (a response rate of 25.8%), of whom 68.9% were European, and 81.1% practising for more than 10 years. Nineteen paediatricians responded. The most widely available technique was NVC (72.7%). Nailfold capillaroscopy was most frequently performed by the physician him/herself, using different types of equipment relating to availability. Most rheumatologists reported high levels of appropriateness for NVC in both clinical and research settings for global assessment and differential diagnosis of Rp. Other techniques were less used. Of all the different techniques, nailfold capillaroscopy was the one most used in both clinical and research settings by adult physicians, the majority of whom use NVC in their everyday practice. The low proportion of clinicians using other techniques suggests that these are currently mainly research tools, available only in specialist centres