389 research outputs found

    Food and religion in Sicily: new green tourist destination by an ancient route from the past.

    Get PDF
    The Francigena Way (Via Francigena) is a long international itinerary that was awarded recognition as a Culture Route of the Council of Europe. It starts in Canterbury (UK), touches 13 European regions and ends in Rome. An ancient track of this route is in Sicily (Southern Italy), and its name is Magna Via Francigena (Great Francigena Way). This track is a pilgrimage route that con-nects two ancient port cities, Palermo and Agrigento, passing through internal rural territories that now deal with the exodus of population from rural to urban areas. The route passes through the Sicilian territory named “Upper-Belìce corleonese”, a rural area around the city of Corleone (a little village known worldwide for the sad Mafia events) that includes a number of municipalities. In the past, this religious pilgrimage was a fundamental part of the expression of faith for Christians and now still represents for Sicilians a strong symbol of Christian identity. In recent decades, pilgrimage tourism around the world has grown significantly each year. The aim of the study is to know the pilgrims’ motivations for choosing the Magna Via Francigena pilgrimage as a vacation and any pos-sible similarities between pilgrimage tourism and food and wine tourism, in the wider context of sustainable and slow tourism. The Policy Delphi method was applied to collect the opinions of the stakeholders involved. The study highlighted the strong link between religious motivations and local enogastronomy, culture, art and nature. Results will support policy-making in the development of integrated territorial tourist marketing strategies

    Behaviour of a speargun with a novel muzzle

    Get PDF
    The paper presents the results of a numerical and experimental investigation performed on a barrel of a speargun equipped with two kinds of muzzle. In particular, a standard muzzle for speargun (having an elastic propulsion) has been compared with an innovative one called 'roller'. This new muzzle is equipped with two rollers and special bands. The rubber bands, fixed at the lower side of the barrel, run through the rollers and are engaged in suitable seats of the shaft. These bands are, therefore, longer than the traditional ones and, consequently, with equal force applied by the diver, the roller speargun has a longer range. Thanks to the particular geometry of the new muzzle, one of the front constraints of the elastic bands is moved to the lower part of the barrel or the handle.As a consequence, the scheme of the loads applied on the speargun remarkably changes passing from a standard muzzle to a roller one. All that has a great influence on the level of deformation of the barrel and, consequently, on the accuracy of the shot. Because of the low velocity of the spear (if compared with the firearms), in fact, the accuracy of the shoot if strongly influenced by the barrel bending due to the forces applied by means of the elastic bands. In this paper it is experimentally evaluated the bending of the barrel equipped both with the innovative muzzle and with the traditional one in order to compare their performances. The experimental analysis of the barrel was performed by electrical strain gauges suitably located at the section with the highest values of the strains. In order to find the barrel section with the highest strain values where to locate the strain gauges, a preliminary numerical FEM analysis has been performed. The loads and constraints scheme has been evaluated both for the standard and the new muzzle. In particular, the forces due to the elastic bands, their application points and directions have been experimentally obtained. To speed up the process of numerical simulation, without invalidating the results reliability, simplified FEM models have been used. In particular, a very accurate model of the barrel has been shaped, whereas the models of the muzzles and the handle have been simplified. The forces due to the elastic bands, experimentally obtained, have been applied on the FEM models. The maps of the maximum and minimum principal strains have allowed to find the area with the highest strain values, placed in rear part of the barrel (near the handle). The strain values experimentally measured on the speargun have been very similar to the ones calculated by means of the numerical simulations. That demonstrates the developed FEM models are very reliable and can ben used to predict the performances of the speragun under different loads conditions. The speargun with the new roller muzzle shows very lower strain values if compared with the ones measured in the standard one. Nevertheless, considering the two spearguns have different elastic bands setup, it has been thought the comparison of their performances should be made hypothesizing the same maximum force applied during the speargun charge. This condition, moreover, could be really obtained by changing the kind of the elastic bands in the speargun with the roller muzzle. For this reason, during the results analysis phase, the strain values measured on the roller speargun have been 'normalized' by increasing them of a value equal to the ratio of the maximum forces due to the rubber bands. The data post processing has allowed to evaluate the forces and the bending moments on the barrels with the standard muzzle and the roller one. Results show the barrel with the innovative muzzle has, also considering equal forces applied by the diver, a lower bending than the barrel with a traditional muzzle. To evaluate the maximum deflection of both the spearguns, a new numerical simulation has been set up. In particular, in this FEM analysis, the roller speargung has been loaded with a maximum force comparable with the standard one. The obtained results show that the standard speargun has a higher value of the maximum deflection respect to the roller one. Since higher deflection values of the barrel make worse the accuracy of the shot, these results demonstrate the novel speargun can be more precise than the traditional one

    Contact between the components of a knee prosthesis: numerical and experimental study

    Get PDF
    The aim of this work is the analysis of the contact area in a knee prosthesis using two different approaches. In particular, the interface between the femoral component and the polyethylene insert has been studied both numerically and experimentally. The interest in studying the contact area is related to the fact that the wear of the polyethylene insert, due to the high contact pressures, represents one of the major causes of failure of the total knee prosthesis. The possibility to evaluate the contact area at different loads and mutual position between femur and tibia is, therefore, of fundamental importance to study the service life of a prosthesis and to improve its performance. The finite element numerical approach has required the acquisition, through reverse engineering, and CAD modelling of the prosthetic components. Then the FEM simulations have been developed considering two different load conditions. In order to compare the calculated data, the same load configurations have been used for experimental tests based on ultrasonic method. In this case, some preliminary tests were required to calibrate the system depending on the particular characteristics of materials, geometries and surface finish of the prosthesis.The results show a good correlation between the data obtained with the two different approaches and, consequently, a good level of reliability of the procedures developed for the numerical and experimental evaluation of the contact area. The numerical procedure can be used to determine the area for different angles and loads, but especially in the design phase. The ultrasonic technique can be used to validate the numerical data

    A reverse engineering approach to measure the deformations of a sailing yacht

    Get PDF
    In this work, a multidisciplinary experience, aimed to study the permanent deformations of the hull of a regatta sailing yacht is described. In particular, a procedure to compare two different surfaces of the hull of a small sailing yacht, designed and manufactured at the University of Palermo, has been developed. The first one represents the original CAD model while the second one has been obtained by means of a reverse engineering approach. The reverse engineering process was performed through an automatic close-range photogrammetry survey, that has allowed to obtain very accurate measures of the hull, and a 3D modelling step by the well-known 3D computer graphics software Rhinoceros. The reverse engineering model was checked through two different procedures implemented by the graphical algorithm editor Grasshopper. The first procedure has allowed to compare the photogrammetric measurements with the rebuilt surface, in order to verify if the reverse engineering process has led to reliable results. The second has been implement to measure the deviations between the original CAD model and the rebuilt surface of the hull. This procedure has given the possibility to highlight any permanent deformation of the hull due to errors during the production phase or to excessive loads during its use. The obtained results have demonstrated that the developed procedure is very efficient and able to give detailed information on the deviation values of the two compared surfaces

    Contact between the components of a knee prosthesis: numerical and experimental study

    Get PDF
    The aim of this work is the analysis of the contact area in a knee prosthesis using two different approaches. In particular, the interface between the femoral component and the polyethylene insert has been studied both numerically and experimentally. The interest in studying the contact area is related to the fact that the wear of the polyethylene insert, due to the high contact pressures, represents one of the major causes of failure of the total knee prosthesis. The possibility to evaluate the contact area at different loads and mutual position between femur and tibia is, therefore, of fundamental importance to study the service life of a prosthesis and to improve its performance. The finite element numerical approach has required the acquisition, through reverse engineering, and CAD modelling of the prosthetic components. Then the FEM simulations have been developed considering two different load conditions. In order to compare the calculated data, the same load configurations have been used for experimental tests based on ultrasonic method. In this case, some preliminary tests were required to calibrate the system depending on the particular characteristics of materials, geometries and surface finish of the prosthesis.The results show a good correlation between the data obtained with the two different approaches and, consequently, a good level of reliability of the procedures developed for the numerical and experimental evaluation of the contact area. The numerical procedure can be used to determine the area for different angles and loads, but especially in the design phase. The ultrasonic technique can be used to validate the numerical data

    Behaviour of a speargun with a novel muzzle - Comportamento di un fucile subacqueo con testata innovativa

    Get PDF
    The paper presents the results of a numerical and experimental investigation performed on a barrel of a speargun equipped with two kinds of muzzle. In particular, a standard muzzle for speargun (having an elastic propulsion) has been compared with an innovative one called ‘roller’. This new muzzle is equipped with two rollers and special bands. The rubber bands, fixed at the lower side of the barrel, run through the rollers and are engaged in suitable seats of the shaft. These bands are, therefore, longer than the traditional ones and,consequently, with equal force applied by the diver, the roller speargun has a longer range. Thanks to theparticular geometry of the new muzzle, one of the front constraints of the elastic bands is moved to the lowerpart of the barrel or the handle.As a consequence, the scheme of the loads applied on the speargun remarkably changes passing from a standard muzzle to a roller one. All that has a great influence on the level of deformation of the barrel and, consequently, on the accuracy of the shot. Because of the low velocity of the spear (if compared with the firearms), in fact, the accuracy of the shoot if strongly influenced by the barrel bending due to the forces applied by means of the elastic bands

    Comparison of two disaster drills' management performed by trained and not-trained students: key times evaluation

    Get PDF
    Introduction The aim of this report is to compare two disaster exercises' management of students with different backgrounds. To our knowledge nobody has ever compared two exercises, probably because of the difficulty in their evaluation. We implemented a tool for an objective evaluation [1] and we used it for this purpose. Methods Both drills represented a ceiling collapse over a crowded room with a similar amount of casualties and similar severity index. The START triage system was used. The trained students (T) were attending the European Master in Disaster Medicine (EMDM), while the not-trained students (NT) were at the beginning of an introductory course in disaster medicine. During the exercises we recorded key victim-provider interaction times [2] using victim-based data collection. Each victim had their own data card to record triage and time information. Results In this preliminary report we present data regarding the scene length of stay (LOS) and triage to collecting area/advanced medical post time (T-AMP). The LOS was 67.5 (50.0 to 111.0) minutes (25 to 75 IQR) for T as compared with 145.0 (110.0 to 150.0) minutes (25 to 75 IQR) for NT (P < 0.001). Stratification according to assigned triage code showed no difference for high-priority codes (reds and yellows) as opposed to the green code (55.0 (47.0 to 75.0) minutes for T vs 145.0 (141.0 to 155.0) minutes for NT with P < 0.01). T-AMP was 10.0 (3.0 to 34.5) minutes for T as compared with 63.5 (19.5 to 104.3) minutes for NT (P < 0.001). Stratification according to triage code showed no difference for red codes between T and NT but showed a difference for yellow codes (36.5 (15.0 to 82.0) vs 71.0 (30.0 to 99.0) minutes) and green codes (7.0 (3.0 to 12.0) vs 85.0 (17.3 to 115.0) minutes) with P < 0.01. Conclusions Both teams evacuated red codes before the yellow ones in similar time. T-AMP was shorter considering global, yellow and green codes for T as opposed to NT. Global and green LOS was also shorter in the T group as opposed to NT. Training seems to influence global exercise management, less affecting red codes but with an impact on yellow and green evacuation strategies

    Evaluation of acute cardiovascular effects of immediate-release methylphenidate in children and adolescents with attention-deficit hyperactivity disorder

    Get PDF
    Attention-deficit hyperactivity disorder is a frequent condition in children and often extends into adulthood. Use of immediate-release methylphenidate (MPH) has raised concerns about potential cardiovascular adverse effects within a few hours after administration. This study was carried out to investigate acute effects of MPH on electrocardiogram (ECG) in a pediatric population. A total of 54 consecutive patients with attention-deficit hyperactivity disorder (51 males and 3 females; mean age =12.14±2.6 years, range 6–19 years), receiving a new prescription of MPH, underwent a standard ECG 2 hours before and after the administration of MPH 10 mg per os. Basal and posttreatment ECG parameters, including mean QT (QT interval when corrected for heart rate [QTc]), QTc dispersion (QTd) interval duration, T-peak to T-end (TpTe) intervals, and TpTe/QT ratio were compared. Significant modifications of both QTc and QTd values were not found after drug administration. QTd fluctuated slightly from 25.7±9.3 milliseconds to 25.1±8.4 milliseconds; QTc varied from 407.6±12.4 milliseconds to 409.8±12.7 milliseconds. A significant variation in blood pressure (systolic blood pressure 105.4±10.3 vs 109.6±11.5; P&lt;0.05; diastolic blood pressure 59.2±7.1 vs 63.1±7.9; P&lt;0.05) was observed, but all the data were within normal range. Heart rate moved from 80.5±15.5 bpm to 87.7±18.8 bpm. No change in TpTe values was found, but a statistically significant increase in TpTe/QTc intervals was found with respect to basal values (0.207±0.02 milliseconds vs 0.214±0.02 milliseconds; P&lt;0.01). The findings of this study show no significant changes in ECG parameters. TpTe values can be an additional parameter to evaluate borderline cases
    corecore